Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Revista Brasileira de Cineantropometria & Desempenho Humano (Online) |
Texto Completo: | https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n2p212 |
Resumo: | There are few studies in the literature concerning the reliability and validity of the quantification of muscle architecture parameters using ultrasound that also report important information such as typical error of measurement (TEM) and intraclass correlation coefficient (ICC). The aim of this study was to use ultrasound imaging to quantify fiber length (FL) and pennation angle (PA) of the gastrocnemius muscle and to determine the reliability and reproducibility of these measurements. Two images of each gastrocnemius of 19 young healthy subjects were acquired using ultrasound equipment (7.5 MHz), in two visits. FL and PA were measured five times on each image, for a total of twenty measurements of each parameter. The overall reliability of the 760 measurements was determined through coefficients of variation (CV), ICC and TEM. The CV of FL ranged from 1.67 to 4.44% and from 3.8 to 11.62% for the PA. All ICC were within the high reliability range, with the exception of the between-visits PA value of the medial gastrocnemius (0.67). The two highest TEM values (3.1° and 3.7°) correspond to the two lowest ICC values (0.67 and 0.83), referring to repeated between-visit measurements of the medial and lateral gastrocnemius. FL measurements of the medial and lateral gastrocnemius had a TEM of 2.17 and 2.25 respectively. The results showed that ultrasound-based measurement of FL and PA exhibits high reliability. |
id |
UFSC-16_24c5c484f7a52c52e75af2625c27f5c9 |
---|---|
oai_identifier_str |
oai:periodicos.ufsc.br:article/20169 |
network_acronym_str |
UFSC-16 |
network_name_str |
Revista Brasileira de Cineantropometria & Desempenho Humano (Online) |
repository_id_str |
|
spelling |
Reliability of triceps surae muscle architecture measurements obtained with sonographic imagingConfiabilidade de medidas de arquitetura muscular do tríceps sural por ultrassonografia de imagemThere are few studies in the literature concerning the reliability and validity of the quantification of muscle architecture parameters using ultrasound that also report important information such as typical error of measurement (TEM) and intraclass correlation coefficient (ICC). The aim of this study was to use ultrasound imaging to quantify fiber length (FL) and pennation angle (PA) of the gastrocnemius muscle and to determine the reliability and reproducibility of these measurements. Two images of each gastrocnemius of 19 young healthy subjects were acquired using ultrasound equipment (7.5 MHz), in two visits. FL and PA were measured five times on each image, for a total of twenty measurements of each parameter. The overall reliability of the 760 measurements was determined through coefficients of variation (CV), ICC and TEM. The CV of FL ranged from 1.67 to 4.44% and from 3.8 to 11.62% for the PA. All ICC were within the high reliability range, with the exception of the between-visits PA value of the medial gastrocnemius (0.67). The two highest TEM values (3.1° and 3.7°) correspond to the two lowest ICC values (0.67 and 0.83), referring to repeated between-visit measurements of the medial and lateral gastrocnemius. FL measurements of the medial and lateral gastrocnemius had a TEM of 2.17 and 2.25 respectively. The results showed that ultrasound-based measurement of FL and PA exhibits high reliability.Há, atualmente, na literatura, poucas pesquisas de confiabilidade e validação da quantificação de parâmetros de arquitetura muscular por ultrassonografia (US), relatando informações importantes como o erro típico da medida (ETM) e o coeficiente de correlação intraclasse (ICC). O objetivo do estudo foi aplicar a técnica de US para quantificar as medidas de comprimento da fibra (CF) e ângulo de penação (AP) dos músculos gastrocnêmios e determinar a confiabilidade e a reprodutibilidade dessas medidas. Duas imagens de cada gastrocnêmio de 19 indivíduos jovens e saudáveis foram adquiridas com um equipamento de ultrassom modo-B (7,5MHz), em duas visitas. CF e AP foram medidos cinco vezes nas duas imagens de cada indivíduo, totalizando vinte medidas de cada parâmetro para cada participante. A confiabilidade do total das 760 medidas foi determinada através do coeficiente de variação (CV), ICC e ETM. O CV do CF variou de 1,67 a 4,44% e do AP de 3,8 a 11,62%. Todos os ICC se encontram no intervalo de grande confiabilidade, com exceção do valor referente à medida interdias do AP do gastrocnêmio medial (0,67). Os dois valores mais altos de ETM (3,1° e 3,7°) correspondem aos dois valores inferiores do ICC (0,67 e 0,83), referentes às medidas repetidas interdias dos gastrocnêmios. As medidas de CF dos gastrocnêmios medial e lateral apresentaram ETM de 2,17mm e 2,25mm, respectivamente. Os resultados obtidos demonstraram que a metodologia utilizada para medição de CF e AP realizada em imagens de ultrassom apresentou alta confiabilidadeUniversidade Federal de Santa Catarina. Florianópolis, SC. Brasil2012-02-14info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion"Avaliado por Pares",DescriptiveAvaliado por ParesDescritivaapplication/pdfhttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n2p21210.1590/1980-0037.2012v14n2p212Brazilian Journal of Kinanthropometry and Human Performance; Vol. 14 No. 2 (2012); 212-220Revista Brasileira de Cineantropometria e Desempenho Humano; v. 14 n. 2 (2012); 212-2201980-00371415-8426reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)instname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCporhttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n2p212/20997Martins, Natalia Santos da FonsecaPeixinho, Carolina CarneiroOliveira, Liliam Fernandes deinfo:eu-repo/semantics/openAccess2022-11-21T14:14:54Zoai:periodicos.ufsc.br:article/20169Revistahttps://periodicos.ufsc.br/index.php/rbcdh/PUBhttps://periodicos.ufsc.br/index.php/rbcdh/oairbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br1980-00371415-8426opendoar:2022-11-21T14:14:54Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)false |
dc.title.none.fl_str_mv |
Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging Confiabilidade de medidas de arquitetura muscular do tríceps sural por ultrassonografia de imagem |
title |
Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging |
spellingShingle |
Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging Martins, Natalia Santos da Fonseca |
title_short |
Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging |
title_full |
Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging |
title_fullStr |
Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging |
title_full_unstemmed |
Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging |
title_sort |
Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging |
author |
Martins, Natalia Santos da Fonseca |
author_facet |
Martins, Natalia Santos da Fonseca Peixinho, Carolina Carneiro Oliveira, Liliam Fernandes de |
author_role |
author |
author2 |
Peixinho, Carolina Carneiro Oliveira, Liliam Fernandes de |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Martins, Natalia Santos da Fonseca Peixinho, Carolina Carneiro Oliveira, Liliam Fernandes de |
description |
There are few studies in the literature concerning the reliability and validity of the quantification of muscle architecture parameters using ultrasound that also report important information such as typical error of measurement (TEM) and intraclass correlation coefficient (ICC). The aim of this study was to use ultrasound imaging to quantify fiber length (FL) and pennation angle (PA) of the gastrocnemius muscle and to determine the reliability and reproducibility of these measurements. Two images of each gastrocnemius of 19 young healthy subjects were acquired using ultrasound equipment (7.5 MHz), in two visits. FL and PA were measured five times on each image, for a total of twenty measurements of each parameter. The overall reliability of the 760 measurements was determined through coefficients of variation (CV), ICC and TEM. The CV of FL ranged from 1.67 to 4.44% and from 3.8 to 11.62% for the PA. All ICC were within the high reliability range, with the exception of the between-visits PA value of the medial gastrocnemius (0.67). The two highest TEM values (3.1° and 3.7°) correspond to the two lowest ICC values (0.67 and 0.83), referring to repeated between-visit measurements of the medial and lateral gastrocnemius. FL measurements of the medial and lateral gastrocnemius had a TEM of 2.17 and 2.25 respectively. The results showed that ultrasound-based measurement of FL and PA exhibits high reliability. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-02-14 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion "Avaliado por Pares", Descriptive Avaliado por Pares Descritiva |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n2p212 10.1590/1980-0037.2012v14n2p212 |
url |
https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n2p212 |
identifier_str_mv |
10.1590/1980-0037.2012v14n2p212 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n2p212/20997 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil |
publisher.none.fl_str_mv |
Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil |
dc.source.none.fl_str_mv |
Brazilian Journal of Kinanthropometry and Human Performance; Vol. 14 No. 2 (2012); 212-220 Revista Brasileira de Cineantropometria e Desempenho Humano; v. 14 n. 2 (2012); 212-220 1980-0037 1415-8426 reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online) instname:Universidade Federal de Santa Catarina (UFSC) instacron:UFSC |
instname_str |
Universidade Federal de Santa Catarina (UFSC) |
instacron_str |
UFSC |
institution |
UFSC |
reponame_str |
Revista Brasileira de Cineantropometria & Desempenho Humano (Online) |
collection |
Revista Brasileira de Cineantropometria & Desempenho Humano (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC) |
repository.mail.fl_str_mv |
rbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br |
_version_ |
1789435122785714176 |