Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging

Detalhes bibliográficos
Autor(a) principal: Martins, Natalia Santos da Fonseca
Data de Publicação: 2012
Outros Autores: Peixinho, Carolina Carneiro, Oliveira, Liliam Fernandes de
Tipo de documento: Artigo
Idioma: por
Título da fonte: Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
Texto Completo: https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n2p212
Resumo: There are few studies in the literature concerning the reliability and validity of the quantification of muscle architecture parameters using ultrasound that also report important information such as typical error of measurement (TEM) and intraclass correlation coefficient (ICC). The aim of this study was to use ultrasound imaging to quantify fiber length (FL) and pennation angle (PA) of the gastrocnemius muscle and to determine the reliability and reproducibility of these measurements. Two images of each gastrocnemius of 19 young healthy subjects were acquired using ultrasound equipment (7.5 MHz), in two visits. FL and PA were measured five times on each image, for a total of twenty measurements of each parameter. The overall reliability of the 760 measurements was determined through coefficients of variation (CV), ICC and TEM. The CV of FL ranged from 1.67 to 4.44% and from 3.8 to 11.62% for the PA. All ICC were within the high reliability range, with the exception of the between-visits PA value of the medial gastrocnemius (0.67). The two highest TEM values (3.1° and 3.7°) correspond to the two lowest ICC values (0.67 and 0.83), referring to repeated between-visit measurements of the medial and lateral gastrocnemius. FL measurements of the medial and lateral gastrocnemius had a TEM of 2.17 and 2.25 respectively. The results showed that ultrasound-based measurement of FL and PA exhibits high reliability.
id UFSC-16_24c5c484f7a52c52e75af2625c27f5c9
oai_identifier_str oai:periodicos.ufsc.br:article/20169
network_acronym_str UFSC-16
network_name_str Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
repository_id_str
spelling Reliability of triceps surae muscle architecture measurements obtained with sonographic imagingConfiabilidade de medidas de arquitetura muscular do tríceps sural por ultrassonografia de imagemThere are few studies in the literature concerning the reliability and validity of the quantification of muscle architecture parameters using ultrasound that also report important information such as typical error of measurement (TEM) and intraclass correlation coefficient (ICC). The aim of this study was to use ultrasound imaging to quantify fiber length (FL) and pennation angle (PA) of the gastrocnemius muscle and to determine the reliability and reproducibility of these measurements. Two images of each gastrocnemius of 19 young healthy subjects were acquired using ultrasound equipment (7.5 MHz), in two visits. FL and PA were measured five times on each image, for a total of twenty measurements of each parameter. The overall reliability of the 760 measurements was determined through coefficients of variation (CV), ICC and TEM. The CV of FL ranged from 1.67 to 4.44% and from 3.8 to 11.62% for the PA. All ICC were within the high reliability range, with the exception of the between-visits PA value of the medial gastrocnemius (0.67). The two highest TEM values (3.1° and 3.7°) correspond to the two lowest ICC values (0.67 and 0.83), referring to repeated between-visit measurements of the medial and lateral gastrocnemius. FL measurements of the medial and lateral gastrocnemius had a TEM of 2.17 and 2.25 respectively. The results showed that ultrasound-based measurement of FL and PA exhibits high reliability.Há, atualmente, na literatura, poucas pesquisas de confiabilidade e validação da quantificação de parâmetros de arquitetura muscular por ultrassonografia (US), relatando informações importantes como o erro típico da medida (ETM) e o coeficiente de correlação intraclasse (ICC). O objetivo do estudo foi aplicar a técnica de US para quantificar as medidas de comprimento da fibra (CF) e ângulo de penação (AP) dos músculos gastrocnêmios e determinar a confiabilidade e a reprodutibilidade dessas medidas. Duas imagens de cada gastrocnêmio de 19 indivíduos jovens e saudáveis foram adquiridas com um equipamento de ultrassom modo-B (7,5MHz), em duas visitas. CF e AP foram medidos cinco vezes nas duas imagens de cada indivíduo, totalizando vinte medidas de cada parâmetro para cada participante. A confiabilidade do total das 760 medidas foi determinada através do coeficiente de variação (CV), ICC e ETM. O CV do CF variou de 1,67 a 4,44% e do AP de 3,8 a 11,62%. Todos os ICC se encontram no intervalo de grande confiabilidade, com exceção do valor referente à medida interdias do AP do gastrocnêmio medial (0,67). Os dois valores mais altos de ETM (3,1° e 3,7°) correspondem aos dois valores inferiores do ICC (0,67 e 0,83), referentes às medidas repetidas interdias dos gastrocnêmios. As medidas de CF dos gastrocnêmios medial e lateral apresentaram ETM de 2,17mm e 2,25mm, respectivamente. Os resultados obtidos demonstraram que a metodologia utilizada para medição de CF e AP realizada em imagens de ultrassom apresentou alta confiabilidadeUniversidade Federal de Santa Catarina. Florianópolis, SC. Brasil2012-02-14info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion"Avaliado por Pares",DescriptiveAvaliado por ParesDescritivaapplication/pdfhttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n2p21210.1590/1980-0037.2012v14n2p212Brazilian Journal of Kinanthropometry and Human Performance; Vol. 14 No. 2 (2012); 212-220Revista Brasileira de Cineantropometria e Desempenho Humano; v. 14 n. 2 (2012); 212-2201980-00371415-8426reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)instname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCporhttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n2p212/20997Martins, Natalia Santos da FonsecaPeixinho, Carolina CarneiroOliveira, Liliam Fernandes deinfo:eu-repo/semantics/openAccess2022-11-21T14:14:54Zoai:periodicos.ufsc.br:article/20169Revistahttps://periodicos.ufsc.br/index.php/rbcdh/PUBhttps://periodicos.ufsc.br/index.php/rbcdh/oairbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br1980-00371415-8426opendoar:2022-11-21T14:14:54Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging
Confiabilidade de medidas de arquitetura muscular do tríceps sural por ultrassonografia de imagem
title Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging
spellingShingle Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging
Martins, Natalia Santos da Fonseca
title_short Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging
title_full Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging
title_fullStr Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging
title_full_unstemmed Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging
title_sort Reliability of triceps surae muscle architecture measurements obtained with sonographic imaging
author Martins, Natalia Santos da Fonseca
author_facet Martins, Natalia Santos da Fonseca
Peixinho, Carolina Carneiro
Oliveira, Liliam Fernandes de
author_role author
author2 Peixinho, Carolina Carneiro
Oliveira, Liliam Fernandes de
author2_role author
author
dc.contributor.author.fl_str_mv Martins, Natalia Santos da Fonseca
Peixinho, Carolina Carneiro
Oliveira, Liliam Fernandes de
description There are few studies in the literature concerning the reliability and validity of the quantification of muscle architecture parameters using ultrasound that also report important information such as typical error of measurement (TEM) and intraclass correlation coefficient (ICC). The aim of this study was to use ultrasound imaging to quantify fiber length (FL) and pennation angle (PA) of the gastrocnemius muscle and to determine the reliability and reproducibility of these measurements. Two images of each gastrocnemius of 19 young healthy subjects were acquired using ultrasound equipment (7.5 MHz), in two visits. FL and PA were measured five times on each image, for a total of twenty measurements of each parameter. The overall reliability of the 760 measurements was determined through coefficients of variation (CV), ICC and TEM. The CV of FL ranged from 1.67 to 4.44% and from 3.8 to 11.62% for the PA. All ICC were within the high reliability range, with the exception of the between-visits PA value of the medial gastrocnemius (0.67). The two highest TEM values (3.1° and 3.7°) correspond to the two lowest ICC values (0.67 and 0.83), referring to repeated between-visit measurements of the medial and lateral gastrocnemius. FL measurements of the medial and lateral gastrocnemius had a TEM of 2.17 and 2.25 respectively. The results showed that ultrasound-based measurement of FL and PA exhibits high reliability.
publishDate 2012
dc.date.none.fl_str_mv 2012-02-14
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
"Avaliado por Pares",
Descriptive
Avaliado por Pares
Descritiva
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n2p212
10.1590/1980-0037.2012v14n2p212
url https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n2p212
identifier_str_mv 10.1590/1980-0037.2012v14n2p212
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2012v14n2p212/20997
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
publisher.none.fl_str_mv Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
dc.source.none.fl_str_mv Brazilian Journal of Kinanthropometry and Human Performance; Vol. 14 No. 2 (2012); 212-220
Revista Brasileira de Cineantropometria e Desempenho Humano; v. 14 n. 2 (2012); 212-220
1980-0037
1415-8426
reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
collection Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
repository.name.fl_str_mv Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv rbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br
_version_ 1789435122785714176