Validity of a new stabilometric force platform for postural balance evaluation.

Detalhes bibliográficos
Autor(a) principal: Ache Dias, Jonathan
Data de Publicação: 2011
Outros Autores: Borges, Lucas, Mattos, Daniela Junckes da Silva, Wentz, Marcelo Diederichs, Domenech, Susana Cristina, Kauffmann, Philippe, Borges Junior, Noé Gomes
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
Texto Completo: https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n5p367
Resumo: The objective of this study was to validate a new stabilometric force platform (SFP). For this, three steps have been established: a) to determine the force threshold to reach an acceptable level of accuracy of the centre of pressure (CoP) measurement by the application of single point load; b) to determine the accuracy of the CoP measurement in the application of distributed load simulating the human feet; c) to verify the concurrent validity of the SFP by comparing it with a commercial force platform (FP). The tests performed in steps “a” and “b” were conducted by applying loads on the SFP using a universal testing machine. In the application of single point load, the mean force threshold presented by the SFP was 315.6 ± 140.5 N. The CoP measurement error in the points near the centre of the SFP was 1.04 ± 0.80 mm in medial-lateral (ML) and 1.31 ± 0.99 mm in anteriorposterior (AP) direction. In the points near the edges of the plate, the error was 2.03 ± 0.91mm (ML) and 1.54 ± 0.96 mm (AP). In the test with distributed loads, errors of less than 1mm were found. Additionally, no differences were found in the CoP parameters between SFP and the FP. The CoP measurement signal presented high correlation between both equipments in AP (r = 0.997 ± 0.001) and ML (r = 0.988 ± 0.003) directions. These findings suggest that the SFP can be used in scientific investigations of balance in quiet standing.
id UFSC-16_cc7a61256c642810f7026b730807815f
oai_identifier_str oai:periodicos.ufsc.br:article/16273
network_acronym_str UFSC-16
network_name_str Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
repository_id_str
spelling Validity of a new stabilometric force platform for postural balance evaluation.Validade de uma nova plataforma de forças estabilométrica para avaliação do equilíbrio posturalThe objective of this study was to validate a new stabilometric force platform (SFP). For this, three steps have been established: a) to determine the force threshold to reach an acceptable level of accuracy of the centre of pressure (CoP) measurement by the application of single point load; b) to determine the accuracy of the CoP measurement in the application of distributed load simulating the human feet; c) to verify the concurrent validity of the SFP by comparing it with a commercial force platform (FP). The tests performed in steps “a” and “b” were conducted by applying loads on the SFP using a universal testing machine. In the application of single point load, the mean force threshold presented by the SFP was 315.6 ± 140.5 N. The CoP measurement error in the points near the centre of the SFP was 1.04 ± 0.80 mm in medial-lateral (ML) and 1.31 ± 0.99 mm in anteriorposterior (AP) direction. In the points near the edges of the plate, the error was 2.03 ± 0.91mm (ML) and 1.54 ± 0.96 mm (AP). In the test with distributed loads, errors of less than 1mm were found. Additionally, no differences were found in the CoP parameters between SFP and the FP. The CoP measurement signal presented high correlation between both equipments in AP (r = 0.997 ± 0.001) and ML (r = 0.988 ± 0.003) directions. These findings suggest that the SFP can be used in scientific investigations of balance in quiet standing.O objetivo deste estudo foi validar uma nova plataforma de forças estabilométrica (PFE). Para isso, três etapas foram estabelecidas: a) determinar o limiar de carga para chegar a um nível aceitável de exatidão da medida do centro de pressão (CP) pela aplicação de cargas pontuais; b) determinar a exatidão da medida do CP na aplicação de cargas distribuídas que simulam os pés humanos; c) verificar a validade concorrente da PFE comparando-a com uma plataforma de forças comercial (PF). Os testes das etapas “a” e “b” foram realizados pela aplicação de cargas sobre a PFE, utilizando uma máquina de ensaios universal. Na etapa de aplicação de carga pontual, a média do limiar de carga apresentado pela PFE foi de 315.6 ± 140.5 N. Os erros de medida do CP nos pontos próximos ao centro da PFE foram de 1.04 ± 0.80 mm na direção medio-lateral (ML) e 1.31 ± 0.99 mm na direção ântero-posterior (AP). Nos pontos próximos aos cantos da chapa, foram encontrados erros de 2.03 ± 0.91 mm (ML) e 1.54 ± 0.96 mm (AP). No teste com cargas distribuídas, os erros foram menores que 1 mm. Adicionalmente, não foram encontradas diferenças nos parâmetros do CP entre a PFE e a PF. O sinal do CP apresentou alta correlação entre os dois equipamentos, tanto na direção AP (r = 0.997 ± 0,001) quanto na direção ML (r = 0.988 ± 0,003). Os resultados sugerem que a PFE pode ser utilizada em estudos científicos do equilíbrio em postura ereta.Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil2011-08-26info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion"Avaliado por Pares",Avaliado por Paresapplication/pdfhttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n5p36710.1590/1980-0037.2011v13n5p367Brazilian Journal of Kinanthropometry and Human Performance; Vol. 13 No. 5 (2011); 367-372Revista Brasileira de Cineantropometria e Desempenho Humano; v. 13 n. 5 (2011); 367-3721980-00371415-8426reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)instname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCenghttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n5p367/18691Ache Dias, JonathanBorges, LucasMattos, Daniela Junckes da SilvaWentz, Marcelo DiederichsDomenech, Susana CristinaKauffmann, PhilippeBorges Junior, Noé Gomesinfo:eu-repo/semantics/openAccess2022-11-21T14:14:54Zoai:periodicos.ufsc.br:article/16273Revistahttps://periodicos.ufsc.br/index.php/rbcdh/PUBhttps://periodicos.ufsc.br/index.php/rbcdh/oairbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br1980-00371415-8426opendoar:2022-11-21T14:14:54Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Validity of a new stabilometric force platform for postural balance evaluation.
Validade de uma nova plataforma de forças estabilométrica para avaliação do equilíbrio postural
title Validity of a new stabilometric force platform for postural balance evaluation.
spellingShingle Validity of a new stabilometric force platform for postural balance evaluation.
Ache Dias, Jonathan
title_short Validity of a new stabilometric force platform for postural balance evaluation.
title_full Validity of a new stabilometric force platform for postural balance evaluation.
title_fullStr Validity of a new stabilometric force platform for postural balance evaluation.
title_full_unstemmed Validity of a new stabilometric force platform for postural balance evaluation.
title_sort Validity of a new stabilometric force platform for postural balance evaluation.
author Ache Dias, Jonathan
author_facet Ache Dias, Jonathan
Borges, Lucas
Mattos, Daniela Junckes da Silva
Wentz, Marcelo Diederichs
Domenech, Susana Cristina
Kauffmann, Philippe
Borges Junior, Noé Gomes
author_role author
author2 Borges, Lucas
Mattos, Daniela Junckes da Silva
Wentz, Marcelo Diederichs
Domenech, Susana Cristina
Kauffmann, Philippe
Borges Junior, Noé Gomes
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Ache Dias, Jonathan
Borges, Lucas
Mattos, Daniela Junckes da Silva
Wentz, Marcelo Diederichs
Domenech, Susana Cristina
Kauffmann, Philippe
Borges Junior, Noé Gomes
description The objective of this study was to validate a new stabilometric force platform (SFP). For this, three steps have been established: a) to determine the force threshold to reach an acceptable level of accuracy of the centre of pressure (CoP) measurement by the application of single point load; b) to determine the accuracy of the CoP measurement in the application of distributed load simulating the human feet; c) to verify the concurrent validity of the SFP by comparing it with a commercial force platform (FP). The tests performed in steps “a” and “b” were conducted by applying loads on the SFP using a universal testing machine. In the application of single point load, the mean force threshold presented by the SFP was 315.6 ± 140.5 N. The CoP measurement error in the points near the centre of the SFP was 1.04 ± 0.80 mm in medial-lateral (ML) and 1.31 ± 0.99 mm in anteriorposterior (AP) direction. In the points near the edges of the plate, the error was 2.03 ± 0.91mm (ML) and 1.54 ± 0.96 mm (AP). In the test with distributed loads, errors of less than 1mm were found. Additionally, no differences were found in the CoP parameters between SFP and the FP. The CoP measurement signal presented high correlation between both equipments in AP (r = 0.997 ± 0.001) and ML (r = 0.988 ± 0.003) directions. These findings suggest that the SFP can be used in scientific investigations of balance in quiet standing.
publishDate 2011
dc.date.none.fl_str_mv 2011-08-26
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
"Avaliado por Pares",
Avaliado por Pares
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n5p367
10.1590/1980-0037.2011v13n5p367
url https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n5p367
identifier_str_mv 10.1590/1980-0037.2011v13n5p367
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n5p367/18691
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
publisher.none.fl_str_mv Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
dc.source.none.fl_str_mv Brazilian Journal of Kinanthropometry and Human Performance; Vol. 13 No. 5 (2011); 367-372
Revista Brasileira de Cineantropometria e Desempenho Humano; v. 13 n. 5 (2011); 367-372
1980-0037
1415-8426
reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
collection Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
repository.name.fl_str_mv Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv rbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br
_version_ 1789435122327486464