Reliability of measurements derived from the palpation method of a software for postural evaluation: does clinical experience matter?
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista Brasileira de Cineantropometria & Desempenho Humano (Online) |
Texto Completo: | https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2018v20n6p515 |
Resumo: | The postural evaluation software (SAPO) has been used as a valuable tool for the analysis of postural alterations, however, such a tool depends on palpation performed by the evaluator. The aim of the present study was to evaluate the inter- and intra-examiner reliability of experienced and inexperienced examiners in measurements derived from the palpation method, and its possible influence on measurements obtained by SAPO. Nine evaluators participated in the study, which were divided into three groups according to experience with respect to palpation (GI: inexperienced group, GSE: semi-experienced group and GE: experienced group). Each evaluator performed the postural analysis of 10 volunteers, which were photographed in orthostatic position, following the SAPO recommendations. The intra-examiner reliability analysis indicated that all three groups had higher, good and moderate mean correlation values for each examiner than low correlations. In the inter-examiner reliability assessment, GE and GSE groups exhibited higher correlation values. The intra-class correlation coefficient, in the single-measure analysis, presented correlation coefficients <0.70 in 9 of the variables analyzed, indicating non-significant correlation. It was concluded that the measures analyzed by SAPO have high intra-examiner reliability. However, regarding inter-examiner reliability, the group composed of inexperienced evaluators presented lower values, suggesting that the experience time may have influenced the inter-examiner reliability regarding postural evaluation. |
id |
UFSC-16_f022c78065acf6ad2cfb5e37e6216d0b |
---|---|
oai_identifier_str |
oai:periodicos.ufsc.br:article/55388 |
network_acronym_str |
UFSC-16 |
network_name_str |
Revista Brasileira de Cineantropometria & Desempenho Humano (Online) |
repository_id_str |
|
spelling |
Reliability of measurements derived from the palpation method of a software for postural evaluation: does clinical experience matter?Fidedignidade nas medidas derivadas do método de palpação de um software para avaliação postural: a experiência clínica importa?The postural evaluation software (SAPO) has been used as a valuable tool for the analysis of postural alterations, however, such a tool depends on palpation performed by the evaluator. The aim of the present study was to evaluate the inter- and intra-examiner reliability of experienced and inexperienced examiners in measurements derived from the palpation method, and its possible influence on measurements obtained by SAPO. Nine evaluators participated in the study, which were divided into three groups according to experience with respect to palpation (GI: inexperienced group, GSE: semi-experienced group and GE: experienced group). Each evaluator performed the postural analysis of 10 volunteers, which were photographed in orthostatic position, following the SAPO recommendations. The intra-examiner reliability analysis indicated that all three groups had higher, good and moderate mean correlation values for each examiner than low correlations. In the inter-examiner reliability assessment, GE and GSE groups exhibited higher correlation values. The intra-class correlation coefficient, in the single-measure analysis, presented correlation coefficients <0.70 in 9 of the variables analyzed, indicating non-significant correlation. It was concluded that the measures analyzed by SAPO have high intra-examiner reliability. However, regarding inter-examiner reliability, the group composed of inexperienced evaluators presented lower values, suggesting that the experience time may have influenced the inter-examiner reliability regarding postural evaluation.O Software de avaliação postural (SAPO) vem sendo utilizado como uma ferramenta valiosa para a análise das alterações posturais, porém tal ferramenta depende da palpação realizada pelo examinador. O objetivo do presente estudo foi avaliar a fidedignidade inter e intraexaminadores experientes e inexperientes nas medidas derivadas do método de palpação, e sua possível influência sobre as medidas obtidas pelo SAPO. Participaram do estudo nove avaliadores, divididos em três grupos de acordo com a experiência com relação a palpação (GI: grupo inexperiente, GSE: grupo semi experiente e GE: grupo experiente). Cada avaliador realizou a análise postural de 10 voluntários, os quais foram fotografados em posição ortostática, seguindo as recomendações do SAPO. A análise da fidedignidade intraexaminadores indicou que os três grupos apresentaram valores de correlação em média mais altos, bons e moderados, do que correlações baixas. Na avaliação da fidedignidade interexaminadores os grupos GE e GSE exibiram valores de correlação mais altos. O coeficiente de correlação intraclasse, na análise de medida única, apresentou índices de correlação <0,70 em 9 das variáveis analisadas, indicando correlação não considerável. Concluiu-se que as medidas analisadas pelo SAPO possuem uma alta fidedignidade intraexaminadores. No entanto, em relação a fidedignidade interexaminadores o grupo composto por examinadores inexperientes com relação a palpação apresentou valores mais baixos, sugerindo que o tempo de experiência dos examinadores pode ter influenciado na fidedignidade interexaminadores da avaliação postural. Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil2018-12-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion"Avaliado por Pares",Original articleAvaliado por ParesArtigo originalapplication/pdfhttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2018v20n6p51510.1590/1980-0037.2018v20n6p515Brazilian Journal of Kinanthropometry and Human Performance; Vol. 20 No. 6 (2018); 515-524Revista Brasileira de Cineantropometria e Desempenho Humano; v. 20 n. 6 (2018); 515-5241980-00371415-8426reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)instname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCenghttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2018v20n6p515/38470Copyright (c) 2019 Revista Brasileira de Cineantropometria e Desempenho Humanoinfo:eu-repo/semantics/openAccessAlmeida, Isabella da SilvaBarreto, Larissa PitangaAndrade, Letícia de SouzaSousa, Caio VictorMota, Yomara Lima2019-03-19T18:40:13Zoai:periodicos.ufsc.br:article/55388Revistahttps://periodicos.ufsc.br/index.php/rbcdh/PUBhttps://periodicos.ufsc.br/index.php/rbcdh/oairbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br1980-00371415-8426opendoar:2019-03-19T18:40:13Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)false |
dc.title.none.fl_str_mv |
Reliability of measurements derived from the palpation method of a software for postural evaluation: does clinical experience matter? Fidedignidade nas medidas derivadas do método de palpação de um software para avaliação postural: a experiência clínica importa? |
title |
Reliability of measurements derived from the palpation method of a software for postural evaluation: does clinical experience matter? |
spellingShingle |
Reliability of measurements derived from the palpation method of a software for postural evaluation: does clinical experience matter? Almeida, Isabella da Silva |
title_short |
Reliability of measurements derived from the palpation method of a software for postural evaluation: does clinical experience matter? |
title_full |
Reliability of measurements derived from the palpation method of a software for postural evaluation: does clinical experience matter? |
title_fullStr |
Reliability of measurements derived from the palpation method of a software for postural evaluation: does clinical experience matter? |
title_full_unstemmed |
Reliability of measurements derived from the palpation method of a software for postural evaluation: does clinical experience matter? |
title_sort |
Reliability of measurements derived from the palpation method of a software for postural evaluation: does clinical experience matter? |
author |
Almeida, Isabella da Silva |
author_facet |
Almeida, Isabella da Silva Barreto, Larissa Pitanga Andrade, Letícia de Souza Sousa, Caio Victor Mota, Yomara Lima |
author_role |
author |
author2 |
Barreto, Larissa Pitanga Andrade, Letícia de Souza Sousa, Caio Victor Mota, Yomara Lima |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Almeida, Isabella da Silva Barreto, Larissa Pitanga Andrade, Letícia de Souza Sousa, Caio Victor Mota, Yomara Lima |
description |
The postural evaluation software (SAPO) has been used as a valuable tool for the analysis of postural alterations, however, such a tool depends on palpation performed by the evaluator. The aim of the present study was to evaluate the inter- and intra-examiner reliability of experienced and inexperienced examiners in measurements derived from the palpation method, and its possible influence on measurements obtained by SAPO. Nine evaluators participated in the study, which were divided into three groups according to experience with respect to palpation (GI: inexperienced group, GSE: semi-experienced group and GE: experienced group). Each evaluator performed the postural analysis of 10 volunteers, which were photographed in orthostatic position, following the SAPO recommendations. The intra-examiner reliability analysis indicated that all three groups had higher, good and moderate mean correlation values for each examiner than low correlations. In the inter-examiner reliability assessment, GE and GSE groups exhibited higher correlation values. The intra-class correlation coefficient, in the single-measure analysis, presented correlation coefficients <0.70 in 9 of the variables analyzed, indicating non-significant correlation. It was concluded that the measures analyzed by SAPO have high intra-examiner reliability. However, regarding inter-examiner reliability, the group composed of inexperienced evaluators presented lower values, suggesting that the experience time may have influenced the inter-examiner reliability regarding postural evaluation. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-12-31 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion "Avaliado por Pares", Original article Avaliado por Pares Artigo original |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2018v20n6p515 10.1590/1980-0037.2018v20n6p515 |
url |
https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2018v20n6p515 |
identifier_str_mv |
10.1590/1980-0037.2018v20n6p515 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2018v20n6p515/38470 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2019 Revista Brasileira de Cineantropometria e Desempenho Humano info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2019 Revista Brasileira de Cineantropometria e Desempenho Humano |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil |
publisher.none.fl_str_mv |
Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil |
dc.source.none.fl_str_mv |
Brazilian Journal of Kinanthropometry and Human Performance; Vol. 20 No. 6 (2018); 515-524 Revista Brasileira de Cineantropometria e Desempenho Humano; v. 20 n. 6 (2018); 515-524 1980-0037 1415-8426 reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online) instname:Universidade Federal de Santa Catarina (UFSC) instacron:UFSC |
instname_str |
Universidade Federal de Santa Catarina (UFSC) |
instacron_str |
UFSC |
institution |
UFSC |
reponame_str |
Revista Brasileira de Cineantropometria & Desempenho Humano (Online) |
collection |
Revista Brasileira de Cineantropometria & Desempenho Humano (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC) |
repository.mail.fl_str_mv |
rbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br |
_version_ |
1789435125164933120 |