Pavimento permeável com superfície em blocos de concreto de alta porosidade
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFSC |
Texto Completo: | http://repositorio.ufsc.br/xmlui/handle/123456789/92148 |
Resumo: | Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Civil. |
id |
UFSC_3a75a9ea5f4590fbdada3cdb4eee44d4 |
---|---|
oai_identifier_str |
oai:repositorio.ufsc.br:123456789/92148 |
network_acronym_str |
UFSC |
network_name_str |
Repositório Institucional da UFSC |
repository_id_str |
2373 |
spelling |
Pavimento permeável com superfície em blocos de concreto de alta porosidadeEngenharia civilBlocos de concretoPorosidadePavimentosDrenagemDissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Civil.Os revestimentos e as estruturas de pavimentos que possuam a capacidade de drenar a água e encaminhá-la, por infiltração às camadas inferiores, possuem relevância em amenizar as inundações ocasionadas principalmente pelo aumento do número de habitações, a insuficiência da capacidade de recolhimento das águas e o crescimento de revestimentos impermeáveis. Portanto, as águas da chuva devem ser evacuadas cada vez mais rapidamente. O presente estudo analisou, em uma primeira etapa, a permeabilidade, porosidade e a resistência à compressão de corpos de prova moldados com concreto de alta porosidade. Foram estudadas seis diferentes granulometrias com agregados de diâmetro máximo 12,7mm e 9,52mm e descontinuidades na granulometria através da retirada de materiais de 0 a 2mm (0/2mm) e 0 a 4mm (0/4mm). Em função dos resultados obtidos nesta primeira etapa, foi adotada a curva granulométrica com agregados de diâmetro máximo 9,52mm e descontinuidade 0/2mm para realização de estudos em uma segunda etapa que contemplou a moldagem de seis corpos de prova para confirmação dos resultados e vinte e quatro blocos em tamanho real para análise de resistência a compressão e execução de uma estrutura teste em um simulador de chuvas montado em laboratório. Para a camada de base desta estrutura foram estudadas quatro curvas granulométricas com diâmetro máximo dos agregados de 19,10mm e com variações na porcentagem de material passante na peneira de abertura 0.074mm de 5%, 8%, 10% e 12%. O ensaio de permeabilidade saturada indicou o uso da porcentagem de 5% por apresentar resultado de permeabilidade mais adequado para o uso na estrutura teste. Para a camada de instalação foi utilizada uma areia grossa com alteração na granulometria através da retirada dos materiais retidos nas peneiras de abertura 0,074mm e 0,150mm. Após o dimensionamento, foi moldada a estrutura teste no simulador de chuvas e submetida a quatro ensaios. O primeiro ensaio foi feito para uma intensidade de 79,1mm/h e teve uma duração de 60 minutos, o segundo para uma intensidade de 19,0mm/h e teve a duração de 480 minutos. Para o terceiro, foi fixada a intensidade em 150,3mm/h e a duração foi de 10 minutos. O quarto ensaio foi realizado nas mesmas condições do terceiro, porém para um tempo de duração de 20 minutos o qual garantiu a ocorrência do escoamento superficial. Para todos os ensaios foram elaboradas análises relacionadas ao volume precipitado sobre a estrutura, volume escoado superficialmente e a vazão de infiltração na estrutura. Para o primeiro e quarto ensaios foram também elaborados estudos relacionados à suas respectivas capacidades de infiltração. A estrutura alvo da pesquisa apresentou comportamento satisfatório quando da ocorrência de precipitações de elevada intensidade e de curta duração que são as precipitações que mais preocupam em relação à ocorrência de inundações. Pavement coverings and the structures that possess the capability of draining and directing water, by infiltration processes to the inferior layers, are relevant in brightening up floodings caused mainly by the increasing of impermeable covering growth and the insufficience of water collecting systems. Therefore, each time rain waters must more quickly be evacuated. The present study analyzed, in an early stage, the permeability, porosity and the compressive resistance of molded bodies of testing exemplars made of high porosity concrete. Six different size distributions were studied with maximum aggregates diameter of 12,7mm and 9,52mm and breaches of 0/2mm and 0/4mm. Depending on the first stage's result, the grading curve was adopted with maximum aggregate diameter of 9.52 mm and breaches on 0/2mm for second stage studies that included the casting of six molded bodies to confirm the results and twenty and four blocks, in actual size, to analyze the resistance to compression and execution of a test structure in a laboratory rain simulator. Four size distributions curves, with maximum diameter of aggregate of 19.10 mm and with variations in the percentage of material passing the 0.074mm sieve-opening of 5%, 8%, 10% and 12%, were examined for the base layer of the structure. The saturated permeability test indicated the use of 5/100 percentage because it's permeability was the most suitable for the use in the test structure. Thick sand was used in the installation layer with a change in size distribution caused by the removal of retained material in sieves of openings 0,074mm and 0,150mm. After the dimensioning, the test structure was shaped and subjected to four raining tests. The first test was done simulating an intensity of 79.1 mm / h over the course of 60 minutes; the second one simulated an intensity of 19.0 mm / h during 480 minutes. For the third test, the intensity was set at 150.3 mm / h with 10 minute duration. The fourth test was conducted under the same conditions of the third, but over 20 minutes which ensured the occurrence of the runoff. Analyses were prepared for all the tests relating the volume precipitated on the structure, surface flow volume and infiltration volume into the structure. For the first and fourth tests, infiltration capacity studies were prepared. The structure under study showed satisfactory behavior when exposed to high intensity, and short duration, precipitation, the most troublesome when concerning to the occurrence of floods.Florianópolis, SCMomm, LetoUniversidade Federal de Santa CatarinaSales, Tarso Luís de2012-10-24T06:12:32Z2012-10-24T06:12:32Z20082008info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis1 v.| il., tabs., grafs.application/pdf262396http://repositorio.ufsc.br/xmlui/handle/123456789/92148porreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccess2013-05-04T07:53:29Zoai:repositorio.ufsc.br:123456789/92148Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732013-05-04T07:53:29Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false |
dc.title.none.fl_str_mv |
Pavimento permeável com superfície em blocos de concreto de alta porosidade |
title |
Pavimento permeável com superfície em blocos de concreto de alta porosidade |
spellingShingle |
Pavimento permeável com superfície em blocos de concreto de alta porosidade Sales, Tarso Luís de Engenharia civil Blocos de concreto Porosidade Pavimentos Drenagem |
title_short |
Pavimento permeável com superfície em blocos de concreto de alta porosidade |
title_full |
Pavimento permeável com superfície em blocos de concreto de alta porosidade |
title_fullStr |
Pavimento permeável com superfície em blocos de concreto de alta porosidade |
title_full_unstemmed |
Pavimento permeável com superfície em blocos de concreto de alta porosidade |
title_sort |
Pavimento permeável com superfície em blocos de concreto de alta porosidade |
author |
Sales, Tarso Luís de |
author_facet |
Sales, Tarso Luís de |
author_role |
author |
dc.contributor.none.fl_str_mv |
Momm, Leto Universidade Federal de Santa Catarina |
dc.contributor.author.fl_str_mv |
Sales, Tarso Luís de |
dc.subject.por.fl_str_mv |
Engenharia civil Blocos de concreto Porosidade Pavimentos Drenagem |
topic |
Engenharia civil Blocos de concreto Porosidade Pavimentos Drenagem |
description |
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Civil. |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008 2008 2012-10-24T06:12:32Z 2012-10-24T06:12:32Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
262396 http://repositorio.ufsc.br/xmlui/handle/123456789/92148 |
identifier_str_mv |
262396 |
url |
http://repositorio.ufsc.br/xmlui/handle/123456789/92148 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
1 v.| il., tabs., grafs. application/pdf |
dc.publisher.none.fl_str_mv |
Florianópolis, SC |
publisher.none.fl_str_mv |
Florianópolis, SC |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFSC instname:Universidade Federal de Santa Catarina (UFSC) instacron:UFSC |
instname_str |
Universidade Federal de Santa Catarina (UFSC) |
instacron_str |
UFSC |
institution |
UFSC |
reponame_str |
Repositório Institucional da UFSC |
collection |
Repositório Institucional da UFSC |
repository.name.fl_str_mv |
Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC) |
repository.mail.fl_str_mv |
|
_version_ |
1808652408941707264 |