Efeito do preaquecimento de sistemas restauradores no desempenho de restaurações em dentes posteriores

Detalhes bibliográficos
Autor(a) principal: Lima, Luana Machado de
Data de Publicação: 2012
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFSC
Texto Completo: http://repositorio.ufsc.br/xmlui/handle/123456789/100616
Resumo: Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia
id UFSC_7fd2d6c431b699075d013b20dfed8832
oai_identifier_str oai:repositorio.ufsc.br:123456789/100616
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Universidade Federal de Santa CatarinaLima, Luana Machado deLopes, Guilherme CarpenaBaratieri, Luiz Narciso2013-06-25T20:55:23Z2013-06-25T20:55:23Z20122012308829http://repositorio.ufsc.br/xmlui/handle/123456789/100616Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em OdontologiaA presente tese teve como objetivo avaliar se o preaquecimento do sistema adesivo e da resina composta foi capaz de promover melhor performance clínica às restaurações em dentes posteriores. Após aprovação do comitê de ética, participaram desta pesquisa 70 pacientes com necessidades de restaurações: oclusal, ocluso-distal ou mesio-oclusal. Utilizou-se do preaquecimento de dois sistemas adesivos [Single Bond 2 (3M ESPE) e P90 Bond (3M ESPE)] e duas resinas compostas: nanoparticulada matriz orgânica metacrilato Filtek#Z350 (3M ESPE) e micro-híbrida matriz orgânica silorano Filtek#P90 (3M ESPE). Esses materiais foram avaliados por um período de 18 meses. Assim, as cavidades pareadas, no mesmo paciente (n=35), formaram os grupos: 1A-Single Bond 2 (3M ESPE), Filtek# Z350 (3M ESPE), sem preaquecimento, (temperatura ambiente, ±25 °C); 1B- mesmos materiais restauradores com preaquecimento (54 °C); 2A- P90 Primer, P90 Bond com Filtek P90 (3M ESPE) sem preaquecimento, (temperatura ambiente, ±25 °C); 2B - mesmos materiais restauradores com preaquecimento (54 °C). Um aparelho de preaquecimento do adesivo e da resina composta, o (Calset#, AdDent Inc., Danbury, CT, EUA), serviu para o propósito. A sensibilidade pós-operatória foi avaliada pela escala de VAS. Após 24 h, as restaurações foram acabadas e polidas. Dois examinadores independentes as avaliaram, conforme método modificado USPHS em intervalos de: 7 dias após o polimento final, 6 meses, 12 meses e 18 meses. Realizaram-se radiografias periapicais e interproximais durante as reavaliações. Foi utilizado o modelo estatístico de regressão logística simples "Razão de Verossimilhança" com nível de significância de 5 % (p<0,05). Em 7 dias, 6 meses, 12 meses e 18 meses após a confecção inicial das restaurações, todas as 140 restaurações (100%) foram avaliadas. Em nenhuma reavaliação houve diferenças significativas nos critérios examinados. Nem a resina composta nem o preaquecimento influenciaram significativamente o desempenho clínico. Em todos os períodos de avaliação, as restaurações se mostraram aceitáveis em todos os quatro grupos para todos os critérios (entre 91,4% e 100% de escores ALFA). Não houve relato de dor. Não houve recidiva de cárie e nem diferenças na adaptação marginal dos materiais ao exame radiográfico. O preaquecimento dos materiais restauradores (sistema adesivo e resina composta) não influenciou a performance clínica. Ao longo dos 18 meses, os materiais e técnicas empregados apresentaram promissores resultados.This thesis aimed to evaluate whether the preheating of the adhesive systems and composite resin was able to promote best clinical performance of restorations in posterior teeth. After approval by the Ethics Committee, 70 patients who needed restorations in occlusal, occlusal-distal or mesio-occlusal participated in this research. The preheating of two adhesive systems [Single Bond 2 (3M ESPE) and P90 Bond (3M ESPE)] as well as two composite resins: metacrilato organic matrix nanoparticulate Filtek#Z350 (3M ESPE) and the silorano organic matrix microhybrid Filtek#P90 (3M ESPE). These materials were evaluated for a period of 18 months. Hereafter are the groups with paired cavities in the same patient (n=35): 1A- Single Bond 2 (3M ESPE), Filtek# Z350 (3M ESPE) without preheating (room temperature, ±25 °C); 1B- same restorative materials with preheating (54 °C); 2A- P90 Primer, P90 Bond (3M ESPE) with Filtek P90 (3M ESPE) without preheating (room temperature ±25 °C); 2B- the same restorative materials with preheating (54 °C). An apparatus for preheating of the adhesive and the composite resin, (Calset#, AdDent Inc., Danbury, CT, EUA) was used for the purpose of this thesis. The Post-operative sensitivity was evaluated using the VAS scale. After 24 h, the restorations were finished and polished. Two independent observers rated the restorations according to the USPHS modified method in intervals of: 7 days, 6 months, 12 months and 18 months after the final polishing. Periapical and bitewing radiographs were used during reassessments. The statistic model of simple logistic regression "Likelihood Ratio" with a significance level of 5 % (p<0,05) has been used in this thesis. All 140 restorations (100%) were evaluated in 7 days, 6 months, 12 months and 18 months after the initial production of the restorations. It has been found no significant difference in the examined criteria during the evaluations. Neither the restorative materials nor the preheating significantly influenced clinical performance. In all evaluation periods, the restorations proved to be acceptable in the four groups for all criteria (between the ALFA 91,4% to 100% of scores ALFA). There were no reports of pain. There was no recurrence of caries and no differences in marginal adaptation of materials to the radiographic examination. The preheating of restorative materials (adhesive system and composite resin) did not influence the clinical performance. Over the 18 months, the materials and techniques employed showed had promising results.151 p.| il., grafs., tabs.porFlorianópolisOdontologiaRestauração (Odontologia)Resinas compostasAdesivos dentariosMateriais dentariosEfeito do preaquecimento de sistemas restauradores no desempenho de restaurações em dentes posterioresinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccessORIGINAL308829.pdfapplication/pdf770581https://repositorio.ufsc.br/bitstream/123456789/100616/1/308829.pdf8278409b6c8fa7aeb27cac498c1d4855MD51123456789/1006162013-06-25 17:55:23.586oai:repositorio.ufsc.br:123456789/100616Repositório de PublicaçõesPUBhttp://150.162.242.35/oai/requestopendoar:23732013-06-25T20:55:23Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.pt_BR.fl_str_mv Efeito do preaquecimento de sistemas restauradores no desempenho de restaurações em dentes posteriores
title Efeito do preaquecimento de sistemas restauradores no desempenho de restaurações em dentes posteriores
spellingShingle Efeito do preaquecimento de sistemas restauradores no desempenho de restaurações em dentes posteriores
Lima, Luana Machado de
Odontologia
Restauração (Odontologia)
Resinas compostas
Adesivos dentarios
Materiais dentarios
title_short Efeito do preaquecimento de sistemas restauradores no desempenho de restaurações em dentes posteriores
title_full Efeito do preaquecimento de sistemas restauradores no desempenho de restaurações em dentes posteriores
title_fullStr Efeito do preaquecimento de sistemas restauradores no desempenho de restaurações em dentes posteriores
title_full_unstemmed Efeito do preaquecimento de sistemas restauradores no desempenho de restaurações em dentes posteriores
title_sort Efeito do preaquecimento de sistemas restauradores no desempenho de restaurações em dentes posteriores
author Lima, Luana Machado de
author_facet Lima, Luana Machado de
author_role author
dc.contributor.pt_BR.fl_str_mv Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Lima, Luana Machado de
dc.contributor.advisor1.fl_str_mv Lopes, Guilherme Carpena
dc.contributor.advisor-co1.fl_str_mv Baratieri, Luiz Narciso
contributor_str_mv Lopes, Guilherme Carpena
Baratieri, Luiz Narciso
dc.subject.classification.pt_BR.fl_str_mv Odontologia
Restauração (Odontologia)
Resinas compostas
Adesivos dentarios
Materiais dentarios
topic Odontologia
Restauração (Odontologia)
Resinas compostas
Adesivos dentarios
Materiais dentarios
description Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia
publishDate 2012
dc.date.submitted.pt_BR.fl_str_mv 2012
dc.date.issued.fl_str_mv 2012
dc.date.accessioned.fl_str_mv 2013-06-25T20:55:23Z
dc.date.available.fl_str_mv 2013-06-25T20:55:23Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.ufsc.br/xmlui/handle/123456789/100616
dc.identifier.other.pt_BR.fl_str_mv 308829
identifier_str_mv 308829
url http://repositorio.ufsc.br/xmlui/handle/123456789/100616
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 151 p.| il., grafs., tabs.
dc.publisher.none.fl_str_mv Florianópolis
publisher.none.fl_str_mv Florianópolis
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
bitstream.url.fl_str_mv https://repositorio.ufsc.br/bitstream/123456789/100616/1/308829.pdf
bitstream.checksum.fl_str_mv 8278409b6c8fa7aeb27cac498c1d4855
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1766805145740378112