Avaliação da atividade e estabilidade da lisozima da clara de ovo submetida ao tratamento com campo magnético

Detalhes bibliográficos
Autor(a) principal: Lima, Palloma Rodrigues de
Data de Publicação: 2017
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFSC
Texto Completo: https://repositorio.ufsc.br/xmlui/handle/123456789/178305
Resumo: Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia de Alimentos, Florianópolis, 2017.
id UFSC_84600b5adc488f78e77ac58ab28d4eac
oai_identifier_str oai:repositorio.ufsc.br:123456789/178305
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Avaliação da atividade e estabilidade da lisozima da clara de ovo submetida ao tratamento com campo magnéticoTecnologia de alimentosEngenharia de alimentosLisozimaCampos magnéticosDissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia de Alimentos, Florianópolis, 2017.As enzimas, são catalisadores biológicos de várias reações bioquímicas por possuírem natureza principalmente proteica e apresentam uma grande especificidade pelo substrato. A lisozima é de particular interesse para o uso em sistemas alimentares, uma vez que é uma enzima que ocorre naturalmente com atividade antimicrobiana, possui ampla disponibilidade e um conhecimento detalhado de suas propriedades, moleculares, incluindo sequência e estrutura. Tratamento de enzimas com base em mudanças de temperatura e pressão, aplicação de ultrassom e de pulsos elétricos podem ser responsáveis por modificações nas suas propriedades e o resultado dessa mudança geralmente é um impedimento ou dificuldade de fixação do substrato na enzima. A aplicação de campos magnéticos, uma tecnologia de simples operação, baixo custo e mínimo impacto ambiental, vem sendo testado como meio de intensificar processos enzimáticos, uma vez que trabalhos na literatura relatam um aumento da atividade e estabilidade de certas enzimas tratadas por campos magnéticos. No entanto, estes trabalhos ainda são escassos e limitados, contemplando poucas enzimas, sendo que a maioria avalia apenas a atividade catalítica da enzima alvo sem estudar os mecanismos de ação do campo magnético e as possíveis alterações estruturais após o tratamento. Neste contexto, nesse trabalho teve-se por objetivo avaliar o efeito do campo magnético e das condições operacionais na atividade catalítica da lisozima da clara de ovo, uma proteína bastante utilizada como modelo pela ampla disponibilidade e conhecimento detalhado sobre sua estrutura nativa. Foram avaliados os efeitos do pH, forca iônica e densidade de fluxo magnético sobre a atividade catalítica desta enzima. O pH e o campo magnético apresentaram efeito significativo sobre a atividade da lisozima, sendo que, o uso do pH na faixa alcalina mais extrema (13,7) e de campo magnético de maior densidade de fluxo magnético (1,34 T) permitiram uma atividade específica residual de 212%, ou seja, um incremento de três vezes a atividade específica da enzima. Os resultados sugerem que a ativação de lisozima causada pelo tratamento magnético pode estar relacionada com as alterações no teor de a-hélice na estrutura secundária, e com o incremento do tamanho de partícula médio, facilitando o acesso do substrato ao sítio ativo da enzima. As modificações do estado natural da lisozima, função do pH e força iônica nas soluções, resultaram num aumento do tamanho de partícula médio e pequenas alterações do potencial zeta.<br>Abstract : Enzymes are biological catalysts involved in many biochemical reactions due mainly to their protein nature and because they present a great specificity for the substrate. The lysozyme is of particular interest for the use in food systems, once it is an enzyme with antimicrobial activity, it possesses a wide availability and detailed knowledge of its molecular properties, including sequence and structure. Enzymes treatment involving temperature and pressure changes, applications of ultrasound and electrical pulses can be responsible for modifications in its properties and the result of such changes are usually associated with stereo impediment or difficulty in substrate - enzyme interaction. The application of magnetic fields, a technology of simple operation, low cost and minimal environmental impact, is being tested as a way to intensify enzymatic processes, since literature reports an increase in activity and stability of certain enzymes treated by magnetic fields. However, these papers are still scarce and limited, contemplating few enzymes, and the majority evaluates only the catalytic activity of the target enzyme without studying the mechanisms of action and the possible structural changes after the treatment. In this context, this work aims to evaluate the effects of the magnetic field and the operational conditions on the catalytic activity of the egg white lysozyme, a protein very used as a model for its wide availability and detailed knowledge about its native structure. The pH and the magnetic field showed a significant effect on lysozyme activity at the highest pH value for the most strongly alkaline range (13.7) and a magnetic field with the highest magnetic flux density (1.34 T) allowed to achieve a residual specific activity of 212%, i.e. an increase of three times the original specific activity of the enzyme. The results suggest that the activation of lysozyme caused by the magnetic treatment may be related to the changes of the a-helix content in the secondary structure, and with the average particle size increase, facilitating the substrate access to the enzyme active site. As changes in the natural state of lysozyme pH function and the ionic strength in the solutions resulted in an increase of the average particle size and small changes on the zeta potential.Di Luccio, MarcoOliveira, José Vladimir deUniversidade Federal de Santa CatarinaLima, Palloma Rodrigues de2017-08-15T04:09:48Z2017-08-15T04:09:48Z2017info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis74 p.| il., gráfs., tabs.application/pdf347193https://repositorio.ufsc.br/xmlui/handle/123456789/178305porreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccess2017-08-15T04:09:48Zoai:repositorio.ufsc.br:123456789/178305Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732017-08-15T04:09:48Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Avaliação da atividade e estabilidade da lisozima da clara de ovo submetida ao tratamento com campo magnético
title Avaliação da atividade e estabilidade da lisozima da clara de ovo submetida ao tratamento com campo magnético
spellingShingle Avaliação da atividade e estabilidade da lisozima da clara de ovo submetida ao tratamento com campo magnético
Lima, Palloma Rodrigues de
Tecnologia de alimentos
Engenharia de alimentos
Lisozima
Campos magnéticos
title_short Avaliação da atividade e estabilidade da lisozima da clara de ovo submetida ao tratamento com campo magnético
title_full Avaliação da atividade e estabilidade da lisozima da clara de ovo submetida ao tratamento com campo magnético
title_fullStr Avaliação da atividade e estabilidade da lisozima da clara de ovo submetida ao tratamento com campo magnético
title_full_unstemmed Avaliação da atividade e estabilidade da lisozima da clara de ovo submetida ao tratamento com campo magnético
title_sort Avaliação da atividade e estabilidade da lisozima da clara de ovo submetida ao tratamento com campo magnético
author Lima, Palloma Rodrigues de
author_facet Lima, Palloma Rodrigues de
author_role author
dc.contributor.none.fl_str_mv Di Luccio, Marco
Oliveira, José Vladimir de
Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Lima, Palloma Rodrigues de
dc.subject.por.fl_str_mv Tecnologia de alimentos
Engenharia de alimentos
Lisozima
Campos magnéticos
topic Tecnologia de alimentos
Engenharia de alimentos
Lisozima
Campos magnéticos
description Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia de Alimentos, Florianópolis, 2017.
publishDate 2017
dc.date.none.fl_str_mv 2017-08-15T04:09:48Z
2017-08-15T04:09:48Z
2017
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv 347193
https://repositorio.ufsc.br/xmlui/handle/123456789/178305
identifier_str_mv 347193
url https://repositorio.ufsc.br/xmlui/handle/123456789/178305
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 74 p.| il., gráfs., tabs.
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1828760385498382336