Efeito do aditivo cristalizante na rede capilar em concretos usinados
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Tipo de documento: | Trabalho de conclusão de curso |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFSC |
Texto Completo: | https://repositorio.ufsc.br/handle/123456789/197506 |
Resumo: | TCC (graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Civil. |
id |
UFSC_fce13413bfb2de2220092dce5dc752fb |
---|---|
oai_identifier_str |
oai:repositorio.ufsc.br:123456789/197506 |
network_acronym_str |
UFSC |
network_name_str |
Repositório Institucional da UFSC |
repository_id_str |
2373 |
spelling |
Efeito do aditivo cristalizante na rede capilar em concretos usinadosConcretoAditivo cristalizantePermeabilidadeDurabilidadeTCC (graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Civil.A degradação das estruturas de concreto é um dos temas de maior importância no contexto da engenharia civil atual. Prevenir a entrada de substâncias agressivas transportadas pela água para dentro dessas estruturas pode representar um aumento significativo de durabilidade. Nesse contexto, a impermeabilização por cristalização integral busca reduzir a entrada de água dentro do concreto através da adição de um aditivo cristalizante durante a produção do concreto. O objetivo desta pesquisa é analisar o desempenho desse aditivo na rede capilar em dois tipos de concretos usinados. Para isso foram moldadas amostras de diferentes relações água/cimento (0,70 e 0,45), representando tanto um concreto de qualidade inferior e alto índice de vazios quanto de elevada qualidade e baixa permeabilidade. Realizaram-se os ensaios de absorção por capilaridade (NBR 9779) e absorção por imersão total (NBR 9778) para analisar como o aditivo cristalizante age no interior do concreto, e também o ensaio de resistência à compressão (NBR 5739) para verificar se a cristalização gera alterações significativas na parte mecânica do material. Também foram analisadas as velocidades de pulso ultrassônico obtidas através do ensaio de ultrassom (NBR 8802), na tentativa de verificação da cristalização, além de possíveis mudanças no módulo de elasticidade dinâmico causadas por esse fenômeno. Além desses ensaios, realizou-se a medição das deformações lineares, baseada na norma NBR 15261, de ambos os concretos, em ambientes de alta e baixa umidade. Os resultados mostram que o aditivo cristalizante é capaz de reduzir a absorção de água por capilaridade do concreto, mas que é necessário um estudo prévio para otimizar sua utilização na prática. Em relação ao ensaio de absorção total, a cristalização não influenciou na absorção e no índice de vazios das amostras analisadas. Quanto às propriedades mecânicas, verifica-se com os resultados obtidos que o aditivo cristalizante não tem a capacidade de aumentar a resistência à compressão do concreto nem de alterar o módulo de elasticidade dinâmico. Por último, foi apresentada a influência do ambiente nas deformações das estruturas de concreto, na qual as amostras armazenadas em local de alta umidade passaram pelo processo de expansão linear, enquanto os corpos de prova posicionados em ambiente de baixa umidade sofreram com o efeito da retração linear.The degradation of concrete structures is one of the most important themes in the context of current civil engineering. Prevent the entry of aggressive substances transported by water into these structures can represent a significant increase in durability. In this situation, integral crystalline waterproofing is intented to reduce the permeability of the concrete by the addition of a crystalline admixture. The aim of this research is to analyze the performance of this material in the capillary network in two types of concretes. For this purpose, two diferente mixtures were molded, with water / cement ratio equal to 0,70 and 0,45, representing as much a high void index and low quality concrete as high quality and low permeability concrete. The capillary water absorption (NBR 9779) and total immersion Absorption (NBR 9778) tests were performed to analyze how the crystalline admixture acts within the concrete, as well as the compressive strength test (NBR 5739) to verify if the integral crystallization generates significant changes in the mechanical properties of the material. Ultrassonic pulse velocity obtained through the UPV test (NBR 8802) were also analyzed in na attempt to verify the integral crystallization and possible changes in the dynamic modulus of elasticity. In addition to these tests, the linear deformation measurement of both concretes were carried out in high and low humidity environments. As a result, it was observed that the crystalline admixture is effective to reduce the water capillarity absorption of the concrete, but a previous study is necessary to optimize its use in practice. Regarding the total absorption test, the integral crystallization did not influence the absorption by total immersion and the voids index of the samples analyzed. Concerning the mechanical properties, it was found that the crystalline admixture does not have the capacity to increase the compressive strenght of the concrete nor to change the dynamic modulus of elasticity. Finally, the influence of the environment in the deformations of the concrete structures was presented, in which the specimen stored in a high humidity local went through the linear expansion process, while the specimen placed in a low humidity environment suffered with the shrinkage effects.Florianópolis, SCRocha, Janaíde CavalcanteUniversidade Federal de Santa CatarinaSombrio, César Schiefler2019-07-12T01:49:48Z2019-07-12T01:49:48Z2019-07-03info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesis123 p.application/pdfhttps://repositorio.ufsc.br/handle/123456789/197506info:eu-repo/semantics/openAccessporreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSC2019-07-12T01:49:48Zoai:repositorio.ufsc.br:123456789/197506Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732019-07-12T01:49:48Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false |
dc.title.none.fl_str_mv |
Efeito do aditivo cristalizante na rede capilar em concretos usinados |
title |
Efeito do aditivo cristalizante na rede capilar em concretos usinados |
spellingShingle |
Efeito do aditivo cristalizante na rede capilar em concretos usinados Sombrio, César Schiefler Concreto Aditivo cristalizante Permeabilidade Durabilidade |
title_short |
Efeito do aditivo cristalizante na rede capilar em concretos usinados |
title_full |
Efeito do aditivo cristalizante na rede capilar em concretos usinados |
title_fullStr |
Efeito do aditivo cristalizante na rede capilar em concretos usinados |
title_full_unstemmed |
Efeito do aditivo cristalizante na rede capilar em concretos usinados |
title_sort |
Efeito do aditivo cristalizante na rede capilar em concretos usinados |
author |
Sombrio, César Schiefler |
author_facet |
Sombrio, César Schiefler |
author_role |
author |
dc.contributor.none.fl_str_mv |
Rocha, Janaíde Cavalcante Universidade Federal de Santa Catarina |
dc.contributor.author.fl_str_mv |
Sombrio, César Schiefler |
dc.subject.por.fl_str_mv |
Concreto Aditivo cristalizante Permeabilidade Durabilidade |
topic |
Concreto Aditivo cristalizante Permeabilidade Durabilidade |
description |
TCC (graduação) - Universidade Federal de Santa Catarina. Centro Tecnológico. Engenharia Civil. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-07-12T01:49:48Z 2019-07-12T01:49:48Z 2019-07-03 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
format |
bachelorThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://repositorio.ufsc.br/handle/123456789/197506 |
url |
https://repositorio.ufsc.br/handle/123456789/197506 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
123 p. application/pdf |
dc.publisher.none.fl_str_mv |
Florianópolis, SC |
publisher.none.fl_str_mv |
Florianópolis, SC |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFSC instname:Universidade Federal de Santa Catarina (UFSC) instacron:UFSC |
instname_str |
Universidade Federal de Santa Catarina (UFSC) |
instacron_str |
UFSC |
institution |
UFSC |
reponame_str |
Repositório Institucional da UFSC |
collection |
Repositório Institucional da UFSC |
repository.name.fl_str_mv |
Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC) |
repository.mail.fl_str_mv |
|
_version_ |
1808652412110503936 |