Evaluation of internal surface alterations in morse taper frictional implant (FGM) and the removal torque of the prosthetic component after mechanical loading associated or not to bacterial biofilm (in vitro)
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Tipo de documento: | Dissertação |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UFSC |
Texto Completo: | https://repositorio.ufsc.br/handle/123456789/215163 |
Resumo: | Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2019. |
id |
UFSC_ff2bd3b9a30b4fd7f0354f0875c6cf8f |
---|---|
oai_identifier_str |
oai:repositorio.ufsc.br:123456789/215163 |
network_acronym_str |
UFSC |
network_name_str |
Repositório Institucional da UFSC |
repository_id_str |
2373 |
spelling |
Evaluation of internal surface alterations in morse taper frictional implant (FGM) and the removal torque of the prosthetic component after mechanical loading associated or not to bacterial biofilm (in vitro)OdontologiaImplantes dentáriosBiofilmesDissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2019.Desgaste no nível da interface implante-pilar devido à instalação do pilar e carga mecânica é inevitável. O objetivo deste estudo in vitro foi avaliar o torque de remoção e os aspectos morfológicos de desgate das superfícies interna de implante cone morse friccional após caregamento mecânico com/sem contato com biofilme. Métodos de estudo: Foram utilizados trinta conjuntos de implantes cone morse e pilares protéticos (FGM), divididos em seis grupos(n=5): Grupo A, sem contato com biofilme, G B, contato com biofilme, G C, 100,000 ciclos de carga mecânica sem contato com biofilme, G D, 100,000 ciclos de carga mecânica e contato com biofilme, G E, 500,000 ciclos de carga mecânica sem contato com biofilme, G F, 500,000 ciclos de carga mecânica e contato com biofilme. Os implantes foram embutidos em resina acrylica transparente através de um padrão para instalar todas as amostras iguais. Os pilares foram ativados através de 3 batidas com o martelete preconizado pela própria FGM. As amostras dos grupos B, D e F ficaram imersos na cultura bacteriana em TSB. Para evitar cargas oblíquas durante a instalação e medição do contra-torque cada bloco das amostras de resina acrílica for colocado em um dispositivo de suporte. Carga mecânica foi realizado a uma força de 80±15 N a 2 Hz à temperatura ambiente. Após a avaliação do torque de remoção do pilar (contra-torque), as superfícies dos implantes foram avaliadas por microscopia eletrônica de varredura (MEV) e por perfilometria óptica. Os resultados foram analisados estatisticamente a um nível de significância de p <0,05, utilizando o software SPSS 17.0 for Windows (Chicago, IL, EUA). Resultados: A avaliação do contra-torque, os valores médios de torque de remoção aumentaram para as amostras com carga mecânica em comparação das amostras sem carga mecânica. O torque de remoção foi maior nas amostras que estavam sob carga mecânica e simultaneamente em contato com biofilme. Áreas de desgaste nas superfícies de conexão com e sem biofilme foram identificadas por MEV. A análise de desgaste revelou que a diferença entre as amostras dos grupos A e B, sem carga mecânica, não foi estatisticamente significativa. O dano da região da borda da superfície interna dos implantes reduziu em amostras imersas no meio de biofilme durante o carregamento mecânico cíclico. Além disso, aumentar o número de ciclos de carga em amostras com contaminação por biofilme, tanto o terço inferior como o terço médio da superfície interna apresentaram menor taxa de desgaste. Conclusões: Em base nos resultados do presente estudo, a presença de biofilme não diminui o torque de remoção no sistema cone morse friccional. A análise de desgaste revelou que o biofilme oral não diminui os valores de taxa de desgaste e rugosidade ao longo de toda a superfície interna dos implantes cone morse friccional.<br>Abstract : Wear at the level of the implant-abutment interface due to the installation of the abutment and mechanical loading is unavoidable. The objective of this in vitro study was to evaluate the removal torque and the morphological aspects of wear of the internal surface in morse taper frictional implant after mechanical loading with or without biofilm contamination. MATERIALS AND METHODS: Thirty sets of morse taper implants and prosthetic abutments (FGM) were divided into six groups (n=5): Group A, without biofilm immersion, G B, with biofilm immersion, G C, 100,000 cycles of mechanical loading without biofilm immersion, G D, 100,000 cycles of mechanical loading with biofilm immersion, G E, 500,000 cycles of mechanical loading without biofilm immersion, G F, 500,000 cycles of mechanical loading with biofilm immersion. The implants were embedded in transparent acrylic resin through a pattern to install all samples equally. The abutments were activated through 3 taps with the special mallet recommended by the FGM. The samples in groups B, D and F were immersed in the medium culture of TSB. To avoid oblique loads during the installation and counter-torque measurement, each block of the acrylic resin samples were placed in a metallic supportive device. Mechanical loading was performed at a force of 80±15 N with a frequency of 2 Hz at room temperature. After removal torque evaluation, internal surface of the implants were evaluated by scanning electron microscopy (SEM) and optical profilometer. The results were statistically analyzed at a significance level of p <0.05, using the software SPSS 17.0 for Windows (Chicago, IL, USA). Results: Evaluation of counter-torque revealed that the mean values of removal torque increased for the samples with mechanical loading compared to the samples with no mechanical loading. The removal torque was higher in samples that were under mechanical load and simultaneously in contact with biofilm. Wear areas on the connection surfaces with and without biofilm were identified by SEM. Wear analysis revealed that the difference between groups A and B samples, without mechanical load, was not statistically significant. The damage of the border region on the internal surface of the implants reduced in samples immersed in the biofilm medium during cyclic mechanical loading. Moreover, by increasing the number of load cycles in samples with biofilm immersion, both the border and middle third parts of internal surfac showed lower wear rate. Conclusions: Base on the present study results, presence of biofilm does not decrease the removal torque in morse taper frictional system. Wear analysis revealed that oral biofilm does not decrease the wear rate and roughness values along the whole internal surface of morse taper frictional implants.Benfatti, Cesar Augusto MagalhãesUniversidade Federal de Santa CatarinaAsmarz, Hamid Yazdanpanah2020-10-21T21:13:42Z2020-10-21T21:13:42Z2019info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis65 p.| il., tabs.application/pdf364079https://repositorio.ufsc.br/handle/123456789/215163engreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccess2020-10-21T21:13:43Zoai:repositorio.ufsc.br:123456789/215163Repositório InstitucionalPUBhttp://150.162.242.35/oai/requestopendoar:23732020-10-21T21:13:43Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false |
dc.title.none.fl_str_mv |
Evaluation of internal surface alterations in morse taper frictional implant (FGM) and the removal torque of the prosthetic component after mechanical loading associated or not to bacterial biofilm (in vitro) |
title |
Evaluation of internal surface alterations in morse taper frictional implant (FGM) and the removal torque of the prosthetic component after mechanical loading associated or not to bacterial biofilm (in vitro) |
spellingShingle |
Evaluation of internal surface alterations in morse taper frictional implant (FGM) and the removal torque of the prosthetic component after mechanical loading associated or not to bacterial biofilm (in vitro) Asmarz, Hamid Yazdanpanah Odontologia Implantes dentários Biofilmes |
title_short |
Evaluation of internal surface alterations in morse taper frictional implant (FGM) and the removal torque of the prosthetic component after mechanical loading associated or not to bacterial biofilm (in vitro) |
title_full |
Evaluation of internal surface alterations in morse taper frictional implant (FGM) and the removal torque of the prosthetic component after mechanical loading associated or not to bacterial biofilm (in vitro) |
title_fullStr |
Evaluation of internal surface alterations in morse taper frictional implant (FGM) and the removal torque of the prosthetic component after mechanical loading associated or not to bacterial biofilm (in vitro) |
title_full_unstemmed |
Evaluation of internal surface alterations in morse taper frictional implant (FGM) and the removal torque of the prosthetic component after mechanical loading associated or not to bacterial biofilm (in vitro) |
title_sort |
Evaluation of internal surface alterations in morse taper frictional implant (FGM) and the removal torque of the prosthetic component after mechanical loading associated or not to bacterial biofilm (in vitro) |
author |
Asmarz, Hamid Yazdanpanah |
author_facet |
Asmarz, Hamid Yazdanpanah |
author_role |
author |
dc.contributor.none.fl_str_mv |
Benfatti, Cesar Augusto Magalhães Universidade Federal de Santa Catarina |
dc.contributor.author.fl_str_mv |
Asmarz, Hamid Yazdanpanah |
dc.subject.por.fl_str_mv |
Odontologia Implantes dentários Biofilmes |
topic |
Odontologia Implantes dentários Biofilmes |
description |
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2019. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019 2020-10-21T21:13:42Z 2020-10-21T21:13:42Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
364079 https://repositorio.ufsc.br/handle/123456789/215163 |
identifier_str_mv |
364079 |
url |
https://repositorio.ufsc.br/handle/123456789/215163 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
65 p.| il., tabs. application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFSC instname:Universidade Federal de Santa Catarina (UFSC) instacron:UFSC |
instname_str |
Universidade Federal de Santa Catarina (UFSC) |
instacron_str |
UFSC |
institution |
UFSC |
reponame_str |
Repositório Institucional da UFSC |
collection |
Repositório Institucional da UFSC |
repository.name.fl_str_mv |
Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC) |
repository.mail.fl_str_mv |
|
_version_ |
1808652199812661248 |