Resumo: | ABSTRACT: Constant monitoring of milk quality by the processing industries demands the use of methodologies that add agility and low-cost analysis, such as the use of electronic equipment based on infrared or ultrasonic spectroscopy. In the present study, quality of raw milk received by dairy farms from western region of Santa Catarina state, Brazil, was evaluated throughout two methodologies of analysis of chemical composition and compared, being that both equipment used standard procedures for calibration, considering as reference data from the classic analytical methods recommended in Brazilian legislation. Milk samples from 45 producers were analyzed for SCC, TBC and physicochemical analysis, performed at dairy’s laboratory and at the official laboratory. Infrared and ultrasound methodologies for chemical composition of fat, protein and lactose were compared and correlated. The comparison of the methods showed that there was no significant difference for the mean values of fat (P=0.06); however, they presented significant difference for protein (P=0.001), higher for IR (3.23 vs. 3.33), and lactose (P<0.0001), higher for US (4.47 vs. 4.83). Correlation was positive and significant for fat (r=0.73, P<0.0001), protein (r=0.47, P=0.001) and lactose (r=0.51, P=0.0003). Considering the minimal composition required, TBC and SCC levels, 95.5%, 84.1% and 64.4% of the milk producers met the current Brazilian legislation, respectively. It was concluded that the methodologies have affected results, which may have been influenced by the correction factor used for equipment calibration, specifically for analyzed samples during the study period. |
id |
UFSM-2_1ab237dabc959ae975116e1b0203714a |
---|---|
oai_identifier_str |
oai:scielo:S0103-84782019000700451 |
network_acronym_str |
UFSM-2 |
network_name_str |
Ciência rural (Online) |
repository_id_str |
|
spelling |
Infrared or ultrasonic milk analysis can affect its results?compositionfast methodsfatmilk qualityproteinABSTRACT: Constant monitoring of milk quality by the processing industries demands the use of methodologies that add agility and low-cost analysis, such as the use of electronic equipment based on infrared or ultrasonic spectroscopy. In the present study, quality of raw milk received by dairy farms from western region of Santa Catarina state, Brazil, was evaluated throughout two methodologies of analysis of chemical composition and compared, being that both equipment used standard procedures for calibration, considering as reference data from the classic analytical methods recommended in Brazilian legislation. Milk samples from 45 producers were analyzed for SCC, TBC and physicochemical analysis, performed at dairy’s laboratory and at the official laboratory. Infrared and ultrasound methodologies for chemical composition of fat, protein and lactose were compared and correlated. The comparison of the methods showed that there was no significant difference for the mean values of fat (P=0.06); however, they presented significant difference for protein (P=0.001), higher for IR (3.23 vs. 3.33), and lactose (P<0.0001), higher for US (4.47 vs. 4.83). Correlation was positive and significant for fat (r=0.73, P<0.0001), protein (r=0.47, P=0.001) and lactose (r=0.51, P=0.0003). Considering the minimal composition required, TBC and SCC levels, 95.5%, 84.1% and 64.4% of the milk producers met the current Brazilian legislation, respectively. It was concluded that the methodologies have affected results, which may have been influenced by the correction factor used for equipment calibration, specifically for analyzed samples during the study period.Universidade Federal de Santa Maria2019-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782019000700451Ciência Rural v.49 n.7 2019reponame:Ciência Ruralinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSM10.1590/0103-8478cr20180510info:eu-repo/semantics/openAccessManske,Guilherme AugustoRigo,ElisandraGomes,Fábio JoséSchogor,Ana Luiza Bachmanneng2019-07-02T00:00:00ZRevista |
dc.title.none.fl_str_mv |
Infrared or ultrasonic milk analysis can affect its results? |
title |
Infrared or ultrasonic milk analysis can affect its results? |
spellingShingle |
Infrared or ultrasonic milk analysis can affect its results? Manske,Guilherme Augusto composition fast methods fat milk quality protein |
title_short |
Infrared or ultrasonic milk analysis can affect its results? |
title_full |
Infrared or ultrasonic milk analysis can affect its results? |
title_fullStr |
Infrared or ultrasonic milk analysis can affect its results? |
title_full_unstemmed |
Infrared or ultrasonic milk analysis can affect its results? |
title_sort |
Infrared or ultrasonic milk analysis can affect its results? |
author |
Manske,Guilherme Augusto |
author_facet |
Manske,Guilherme Augusto Rigo,Elisandra Gomes,Fábio José Schogor,Ana Luiza Bachmann |
author_role |
author |
author2 |
Rigo,Elisandra Gomes,Fábio José Schogor,Ana Luiza Bachmann |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Manske,Guilherme Augusto Rigo,Elisandra Gomes,Fábio José Schogor,Ana Luiza Bachmann |
dc.subject.por.fl_str_mv |
composition fast methods fat milk quality protein |
topic |
composition fast methods fat milk quality protein |
description |
ABSTRACT: Constant monitoring of milk quality by the processing industries demands the use of methodologies that add agility and low-cost analysis, such as the use of electronic equipment based on infrared or ultrasonic spectroscopy. In the present study, quality of raw milk received by dairy farms from western region of Santa Catarina state, Brazil, was evaluated throughout two methodologies of analysis of chemical composition and compared, being that both equipment used standard procedures for calibration, considering as reference data from the classic analytical methods recommended in Brazilian legislation. Milk samples from 45 producers were analyzed for SCC, TBC and physicochemical analysis, performed at dairy’s laboratory and at the official laboratory. Infrared and ultrasound methodologies for chemical composition of fat, protein and lactose were compared and correlated. The comparison of the methods showed that there was no significant difference for the mean values of fat (P=0.06); however, they presented significant difference for protein (P=0.001), higher for IR (3.23 vs. 3.33), and lactose (P<0.0001), higher for US (4.47 vs. 4.83). Correlation was positive and significant for fat (r=0.73, P<0.0001), protein (r=0.47, P=0.001) and lactose (r=0.51, P=0.0003). Considering the minimal composition required, TBC and SCC levels, 95.5%, 84.1% and 64.4% of the milk producers met the current Brazilian legislation, respectively. It was concluded that the methodologies have affected results, which may have been influenced by the correction factor used for equipment calibration, specifically for analyzed samples during the study period. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782019000700451 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782019000700451 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0103-8478cr20180510 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Universidade Federal de Santa Maria |
publisher.none.fl_str_mv |
Universidade Federal de Santa Maria |
dc.source.none.fl_str_mv |
Ciência Rural v.49 n.7 2019 reponame:Ciência Rural instname:Universidade Federal de Santa Maria (UFSM) instacron:UFSM |
instname_str |
Universidade Federal de Santa Maria (UFSM) |
instacron_str |
UFSM |
institution |
UFSM |
reponame_str |
Ciência Rural |
collection |
Ciência Rural |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1749140553892626432 |