Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres mediante radiologia convencional

Detalhes bibliográficos
Autor(a) principal: Cunha, João Paulo Monteiro Carvalho Mori da
Data de Publicação: 2011
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Manancial - Repositório Digital da UFSM
Texto Completo: http://repositorio.ufsm.br/handle/1/10097
Resumo: Acute and Chronic renal diseases have a high morbidity and mortality. There is a good deal of interest in MSC-based approaches for the treatment of Kidney injury, thanks to positive preclinical results and the strong clinical need for novel therapies to treat Acute Kidney Injury. Several routes of administration have been tested and have shown a better response when applied arterially. The main goal of this study was to describe and to compare the use of Fogarty thru-lumen embolectomy catheter with angiographic catheter by using conventional radiology as a guide. We used seven healthy dogs to measure the diameter of the aorta caudal to the renal arteries and right and left femoral and renal arteries. It was assessed the number of attempts for the placement of the introducer, number of radiographic studies to carry out nefrography with both cathethers. In five out of seven animals it was possible to place of the introducer tube 6F. Regarding the number of radiographic films used, the technique with the angiographic catheter needed more than the Fogarty when accessed both arteries, but there is no significant difference when compared to the Fogarty with access to only one renal artery. There was hematoma formation in three animals. The access of the renal artery for drug delivery and cell therapy is possible using both Fogarty thru-lumen embolectomy catheter and angiographic catheter by conventional radiology as a guide, however, we considered the Fogarty catheter easier to be applied, since only one procedure can be performed to access both renal arteries, thus making it less expensive and faster to run. If access to only one renal artery is require, the angiographic catheter would be recommended, since cell therapy would be administered more selectively in the target kidney.
id UFSM_91589b779dbd81fdd52a31a5d9132f93
oai_identifier_str oai:repositorio.ufsm.br:1/10097
network_acronym_str UFSM
network_name_str Manancial - Repositório Digital da UFSM
repository_id_str
spelling Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres mediante radiologia convencionalMinimally invasive approach to renal artery using different types of catheter by conventional radiologyArteriografiaDoença renalTerapia celularIntervencionismoArteriographyRenal diseaseCellular therapyIntervencionismCNPQ::CIENCIAS AGRARIAS::MEDICINA VETERINARIAAcute and Chronic renal diseases have a high morbidity and mortality. There is a good deal of interest in MSC-based approaches for the treatment of Kidney injury, thanks to positive preclinical results and the strong clinical need for novel therapies to treat Acute Kidney Injury. Several routes of administration have been tested and have shown a better response when applied arterially. The main goal of this study was to describe and to compare the use of Fogarty thru-lumen embolectomy catheter with angiographic catheter by using conventional radiology as a guide. We used seven healthy dogs to measure the diameter of the aorta caudal to the renal arteries and right and left femoral and renal arteries. It was assessed the number of attempts for the placement of the introducer, number of radiographic studies to carry out nefrography with both cathethers. In five out of seven animals it was possible to place of the introducer tube 6F. Regarding the number of radiographic films used, the technique with the angiographic catheter needed more than the Fogarty when accessed both arteries, but there is no significant difference when compared to the Fogarty with access to only one renal artery. There was hematoma formation in three animals. The access of the renal artery for drug delivery and cell therapy is possible using both Fogarty thru-lumen embolectomy catheter and angiographic catheter by conventional radiology as a guide, however, we considered the Fogarty catheter easier to be applied, since only one procedure can be performed to access both renal arteries, thus making it less expensive and faster to run. If access to only one renal artery is require, the angiographic catheter would be recommended, since cell therapy would be administered more selectively in the target kidney.Conselho Nacional de Desenvolvimento Científico e TecnológicoA insuficiência renal aguda e crônica são doenças com altos índices de morbidade e mortalidade. O interesse na utilização de células tronco mesenquimais após um insulto renal tem sido crescente, devido ao indício de efeitos positivos em estudos pré-clínicos e a necessidade de novas terapias para tratar lesão renal aguda. Diversas vias de administração já foram testadas, sendo observado que a aplicação na artéria renal é a via de escolha pela sua melhora mais significativa na função renal. Diante disso o objetivo desse estudo foi descrever e comparar a utilização do cateter Fogarty de embolectomia duplo lúmen com o cateter angiográfico utilizando radiologia convencional. Utilizaram-se sete cães hígidos nos quais foram avaliados os diâmetros da aorta caudal às artérias renais e das artérias femorais e renais direita e esquerda. Quantificou-se o número de tentativas para colocação do introdutor e de estudos radiográficos para a realização de nefrografia com ambos cateteres. Em cinco dos sete animais foi possível a realização do acesso vascular pela artéria renal. Quanto ao número de estudos radiográficos, a técnica com o cateter angiográfico precisou de maior número do que o Fogarty quando se acessou ambas artérias, no entanto não houve diferença significativa quando comparou-se o Fogarty com o acesso de apenas uma artéria renal. Houve a formação de hematoma em três animais. O acesso da artéria renal para administração de fármacos e terapia celular é possível utilizando-se tanto o cateter Fogarty duplo lúmen quanto o Angiográfico por meio de radiologia convencional como guia, no entanto, considerou-se o cateter Fogarty o cateter de escolha, visto que em apenas um procedimento consegue-se realizar o acesso de ambas artérias renais, tornando-se dessa forma menos dispendioso e mais rápido de ser executado. Caso seja necessário o acesso de apenas uma artéria renal, sugere-se a utilização do cateter angiográfico, uma vez que a terapia celular seria administrada mais seletivamente no rim alvo.Universidade Federal de Santa MariaBRMedicina VeterináriaUFSMPrograma de Pós-Graduação em Medicina VeterináriaPippi, Ney Luishttp://lattes.cnpq.br/7254479300721225Mazzanti, Alexandrehttp://lattes.cnpq.br/3504517995843014Braga, Fabrício de Vargas Arigonyhttp://lattes.cnpq.br/3493249676781098Cunha, João Paulo Monteiro Carvalho Mori da2017-06-072017-06-072011-04-26info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfapplication/pdfCUNHA, João Paulo Monteiro Carvalho Mori da. Minimally invasive approach to renal artery using different types of catheter by conventional radiology. 2011. 51 f. Dissertação (Mestrado em Medicina Veterinária) - Universidade Federal de Santa Maria, Santa Maria, 2011.http://repositorio.ufsm.br/handle/1/10097porinfo:eu-repo/semantics/openAccessreponame:Manancial - Repositório Digital da UFSMinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSM2022-07-22T12:24:34Zoai:repositorio.ufsm.br:1/10097Biblioteca Digital de Teses e Dissertaçõeshttps://repositorio.ufsm.br/ONGhttps://repositorio.ufsm.br/oai/requestatendimento.sib@ufsm.br||tedebc@gmail.comopendoar:2022-07-22T12:24:34Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)false
dc.title.none.fl_str_mv Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres mediante radiologia convencional
Minimally invasive approach to renal artery using different types of catheter by conventional radiology
title Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres mediante radiologia convencional
spellingShingle Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres mediante radiologia convencional
Cunha, João Paulo Monteiro Carvalho Mori da
Arteriografia
Doença renal
Terapia celular
Intervencionismo
Arteriography
Renal disease
Cellular therapy
Intervencionism
CNPQ::CIENCIAS AGRARIAS::MEDICINA VETERINARIA
title_short Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres mediante radiologia convencional
title_full Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres mediante radiologia convencional
title_fullStr Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres mediante radiologia convencional
title_full_unstemmed Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres mediante radiologia convencional
title_sort Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres mediante radiologia convencional
author Cunha, João Paulo Monteiro Carvalho Mori da
author_facet Cunha, João Paulo Monteiro Carvalho Mori da
author_role author
dc.contributor.none.fl_str_mv Pippi, Ney Luis
http://lattes.cnpq.br/7254479300721225
Mazzanti, Alexandre
http://lattes.cnpq.br/3504517995843014
Braga, Fabrício de Vargas Arigony
http://lattes.cnpq.br/3493249676781098
dc.contributor.author.fl_str_mv Cunha, João Paulo Monteiro Carvalho Mori da
dc.subject.por.fl_str_mv Arteriografia
Doença renal
Terapia celular
Intervencionismo
Arteriography
Renal disease
Cellular therapy
Intervencionism
CNPQ::CIENCIAS AGRARIAS::MEDICINA VETERINARIA
topic Arteriografia
Doença renal
Terapia celular
Intervencionismo
Arteriography
Renal disease
Cellular therapy
Intervencionism
CNPQ::CIENCIAS AGRARIAS::MEDICINA VETERINARIA
description Acute and Chronic renal diseases have a high morbidity and mortality. There is a good deal of interest in MSC-based approaches for the treatment of Kidney injury, thanks to positive preclinical results and the strong clinical need for novel therapies to treat Acute Kidney Injury. Several routes of administration have been tested and have shown a better response when applied arterially. The main goal of this study was to describe and to compare the use of Fogarty thru-lumen embolectomy catheter with angiographic catheter by using conventional radiology as a guide. We used seven healthy dogs to measure the diameter of the aorta caudal to the renal arteries and right and left femoral and renal arteries. It was assessed the number of attempts for the placement of the introducer, number of radiographic studies to carry out nefrography with both cathethers. In five out of seven animals it was possible to place of the introducer tube 6F. Regarding the number of radiographic films used, the technique with the angiographic catheter needed more than the Fogarty when accessed both arteries, but there is no significant difference when compared to the Fogarty with access to only one renal artery. There was hematoma formation in three animals. The access of the renal artery for drug delivery and cell therapy is possible using both Fogarty thru-lumen embolectomy catheter and angiographic catheter by conventional radiology as a guide, however, we considered the Fogarty catheter easier to be applied, since only one procedure can be performed to access both renal arteries, thus making it less expensive and faster to run. If access to only one renal artery is require, the angiographic catheter would be recommended, since cell therapy would be administered more selectively in the target kidney.
publishDate 2011
dc.date.none.fl_str_mv 2011-04-26
2017-06-07
2017-06-07
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv CUNHA, João Paulo Monteiro Carvalho Mori da. Minimally invasive approach to renal artery using different types of catheter by conventional radiology. 2011. 51 f. Dissertação (Mestrado em Medicina Veterinária) - Universidade Federal de Santa Maria, Santa Maria, 2011.
http://repositorio.ufsm.br/handle/1/10097
identifier_str_mv CUNHA, João Paulo Monteiro Carvalho Mori da. Minimally invasive approach to renal artery using different types of catheter by conventional radiology. 2011. 51 f. Dissertação (Mestrado em Medicina Veterinária) - Universidade Federal de Santa Maria, Santa Maria, 2011.
url http://repositorio.ufsm.br/handle/1/10097
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Maria
BR
Medicina Veterinária
UFSM
Programa de Pós-Graduação em Medicina Veterinária
publisher.none.fl_str_mv Universidade Federal de Santa Maria
BR
Medicina Veterinária
UFSM
Programa de Pós-Graduação em Medicina Veterinária
dc.source.none.fl_str_mv reponame:Manancial - Repositório Digital da UFSM
instname:Universidade Federal de Santa Maria (UFSM)
instacron:UFSM
instname_str Universidade Federal de Santa Maria (UFSM)
instacron_str UFSM
institution UFSM
reponame_str Manancial - Repositório Digital da UFSM
collection Manancial - Repositório Digital da UFSM
repository.name.fl_str_mv Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)
repository.mail.fl_str_mv atendimento.sib@ufsm.br||tedebc@gmail.com
_version_ 1805922057749266432