Clinical evaluation of reprocessed blades in LASIK
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNIFESP |
dARK ID: | ark:/48912/001300000j2bn |
DOI: | 10.1590/S0004-27492008000200016 |
Texto Completo: | http://dx.doi.org/10.1590/S0004-27492008000200016 http://repositorio.unifesp.br/handle/11600/4342 |
Resumo: | PURPOSE: To evaluate outcome and complications in LASIK with reprocessed blades. METHODS: Retrospective analysis of patients' charts submitted to complete custom LASIK from January 2004 to June 2005. Inclusion criteria comprised surgical description of blade use and minimum follow-up of 1 month. The blade was reprocessed following a clinic protocol, from 1 to 3 times (reprocessed group) and results compared with patients that underwent LASIK with first-use blades (first-use group). RESULTS: Two hundred fifty-one eyes of 135 patients were analyzed (spherical equivalent of -3.69 (D). There was no statistical differences between first-use group and reprocessed blade group regarding intraoperative (5.5% vs 8.8%), early (50.5% vs 49.5%) and late complications (33% vs 27.5%), respectively. Uncorrected visual acuity > 20/20 (68.1% vs 66.9%), aberrometry analysis (total RMS: 0.62 vs 0.64 µm) and safety (85.7% vs 83.1%) were similar between groups (p>0.05). CONCLUSION: Reprocessed blades following rigid sterilization protocol may have similar outcomes and complications rates in LASIK surgery compared to first-use blades. |
id |
UFSP_0a636b80d4763f1d6827859e2062205c |
---|---|
oai_identifier_str |
oai:repositorio.unifesp.br/:11600/4342 |
network_acronym_str |
UFSP |
network_name_str |
Repositório Institucional da UNIFESP |
repository_id_str |
3465 |
spelling |
Clinical evaluation of reprocessed blades in LASIKAvaliação clínica da utilização de lâminas reprocessadas no LASIKKeratomileusis, laser in situPostoperative complicationsRefractive surgical proceduresRefractive errorsEquipment reuseCeratomileuse assistida por excimer laser in situComplicações pós-operatóriasProcedimentos cirúrgicos refrativosErros de refraçãoReutilização de equipamentosPURPOSE: To evaluate outcome and complications in LASIK with reprocessed blades. METHODS: Retrospective analysis of patients' charts submitted to complete custom LASIK from January 2004 to June 2005. Inclusion criteria comprised surgical description of blade use and minimum follow-up of 1 month. The blade was reprocessed following a clinic protocol, from 1 to 3 times (reprocessed group) and results compared with patients that underwent LASIK with first-use blades (first-use group). RESULTS: Two hundred fifty-one eyes of 135 patients were analyzed (spherical equivalent of -3.69 (D). There was no statistical differences between first-use group and reprocessed blade group regarding intraoperative (5.5% vs 8.8%), early (50.5% vs 49.5%) and late complications (33% vs 27.5%), respectively. Uncorrected visual acuity > 20/20 (68.1% vs 66.9%), aberrometry analysis (total RMS: 0.62 vs 0.64 µm) and safety (85.7% vs 83.1%) were similar between groups (p>0.05). CONCLUSION: Reprocessed blades following rigid sterilization protocol may have similar outcomes and complications rates in LASIK surgery compared to first-use blades.OBJETIVO: Analisar os resultados e complicações do uso de lâminas reprocessadas em cirurgias refrativas com a técnica de LASIK. MÉTODOS: Estudo retrospectivo dos prontuários dos pacientes submetidos a LASIK personalizado durante janeiro de 2004 a junho de 2005. Foram incluídos pacientes que apresentavam relatório transoperatório completo (uso da lâmina) e seguimento mínimo de 1 mês após a cirurgia. O grupo controle foi constituído das lâminas com uso único enquanto no grupo das lâminas reprocessadas poderia variar de 2 a 4 vezes de uso. RESULTADOS: Duzentos e cinqüenta e um olhos de 135 pacientes foram analisados e o equivalente esférico pré-operatório médio foi de -3,69 (D). Não houve diferença significativa entre o número de complicações transoperatórias (5,5% vs 8,8%), pós-operatórias imediatas (50,5% vs 49,5%) e tardias (33% vs 27,5%) entre o grupo de lâminas com uso único e reprocessadas, respectivamente. Os resultados de AV sem correção pós-operatória > 20/20 (68,1% vs 66,9%), aberrometria (RMS total: 0,62 vs 0,64 µm) e segurança (85,7% vs 83,1%) foram similares entre os grupos (p>0,05). CONCLUSÃO: O uso de até 4 vezes da lâmina metálica, seguindo reprocessamento adequado pode apresentar resultados e taxa de complicações semelhantes às cirurgias de LASIK realizadas com lâminas de uso único.Universidade Federal de São Paulo (UNIFESP) Setor de Cirurgia RefrativaUNIFESP Setor de Cirurgia RefrativaUNIFESP Departamento de OftalmologiaUNIFESPUNIFESP, Setor de Cirurgia RefrativaUNIFESP, Setor de Cirurgia RefrativaUNIFESP, Depto. de OftalmologiaUNIFESPSciELOConselho Brasileiro de OftalmologiaUniversidade Federal de São Paulo (UNIFESP)Mallmann, Felipe [UNIFESP]Murata, Celina [UNIFESP]Yamazaki, Ester Sakae [UNIFESP]Campos, Mauro Silveira de Queiroz [UNIFESP]2015-06-14T13:38:31Z2015-06-14T13:38:31Z2008-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion221-227application/pdfhttp://dx.doi.org/10.1590/S0004-27492008000200016Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 71, n. 2, p. 221-227, 2008.10.1590/S0004-27492008000200016S0004-27492008000200016.pdf0004-2749S0004-27492008000200016http://repositorio.unifesp.br/handle/11600/4342ark:/48912/001300000j2bnengArquivos Brasileiros de Oftalmologiainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-07-29T11:12:06Zoai:repositorio.unifesp.br/:11600/4342Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-12-11T20:20:16.231703Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false |
dc.title.none.fl_str_mv |
Clinical evaluation of reprocessed blades in LASIK Avaliação clínica da utilização de lâminas reprocessadas no LASIK |
title |
Clinical evaluation of reprocessed blades in LASIK |
spellingShingle |
Clinical evaluation of reprocessed blades in LASIK Clinical evaluation of reprocessed blades in LASIK Mallmann, Felipe [UNIFESP] Keratomileusis, laser in situ Postoperative complications Refractive surgical procedures Refractive errors Equipment reuse Ceratomileuse assistida por excimer laser in situ Complicações pós-operatórias Procedimentos cirúrgicos refrativos Erros de refração Reutilização de equipamentos Mallmann, Felipe [UNIFESP] Keratomileusis, laser in situ Postoperative complications Refractive surgical procedures Refractive errors Equipment reuse Ceratomileuse assistida por excimer laser in situ Complicações pós-operatórias Procedimentos cirúrgicos refrativos Erros de refração Reutilização de equipamentos |
title_short |
Clinical evaluation of reprocessed blades in LASIK |
title_full |
Clinical evaluation of reprocessed blades in LASIK |
title_fullStr |
Clinical evaluation of reprocessed blades in LASIK Clinical evaluation of reprocessed blades in LASIK |
title_full_unstemmed |
Clinical evaluation of reprocessed blades in LASIK Clinical evaluation of reprocessed blades in LASIK |
title_sort |
Clinical evaluation of reprocessed blades in LASIK |
author |
Mallmann, Felipe [UNIFESP] |
author_facet |
Mallmann, Felipe [UNIFESP] Mallmann, Felipe [UNIFESP] Murata, Celina [UNIFESP] Yamazaki, Ester Sakae [UNIFESP] Campos, Mauro Silveira de Queiroz [UNIFESP] Murata, Celina [UNIFESP] Yamazaki, Ester Sakae [UNIFESP] Campos, Mauro Silveira de Queiroz [UNIFESP] |
author_role |
author |
author2 |
Murata, Celina [UNIFESP] Yamazaki, Ester Sakae [UNIFESP] Campos, Mauro Silveira de Queiroz [UNIFESP] |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade Federal de São Paulo (UNIFESP) |
dc.contributor.author.fl_str_mv |
Mallmann, Felipe [UNIFESP] Murata, Celina [UNIFESP] Yamazaki, Ester Sakae [UNIFESP] Campos, Mauro Silveira de Queiroz [UNIFESP] |
dc.subject.por.fl_str_mv |
Keratomileusis, laser in situ Postoperative complications Refractive surgical procedures Refractive errors Equipment reuse Ceratomileuse assistida por excimer laser in situ Complicações pós-operatórias Procedimentos cirúrgicos refrativos Erros de refração Reutilização de equipamentos |
topic |
Keratomileusis, laser in situ Postoperative complications Refractive surgical procedures Refractive errors Equipment reuse Ceratomileuse assistida por excimer laser in situ Complicações pós-operatórias Procedimentos cirúrgicos refrativos Erros de refração Reutilização de equipamentos |
description |
PURPOSE: To evaluate outcome and complications in LASIK with reprocessed blades. METHODS: Retrospective analysis of patients' charts submitted to complete custom LASIK from January 2004 to June 2005. Inclusion criteria comprised surgical description of blade use and minimum follow-up of 1 month. The blade was reprocessed following a clinic protocol, from 1 to 3 times (reprocessed group) and results compared with patients that underwent LASIK with first-use blades (first-use group). RESULTS: Two hundred fifty-one eyes of 135 patients were analyzed (spherical equivalent of -3.69 (D). There was no statistical differences between first-use group and reprocessed blade group regarding intraoperative (5.5% vs 8.8%), early (50.5% vs 49.5%) and late complications (33% vs 27.5%), respectively. Uncorrected visual acuity > 20/20 (68.1% vs 66.9%), aberrometry analysis (total RMS: 0.62 vs 0.64 µm) and safety (85.7% vs 83.1%) were similar between groups (p>0.05). CONCLUSION: Reprocessed blades following rigid sterilization protocol may have similar outcomes and complications rates in LASIK surgery compared to first-use blades. |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-04-01 2015-06-14T13:38:31Z 2015-06-14T13:38:31Z |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/S0004-27492008000200016 Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 71, n. 2, p. 221-227, 2008. 10.1590/S0004-27492008000200016 S0004-27492008000200016.pdf 0004-2749 S0004-27492008000200016 http://repositorio.unifesp.br/handle/11600/4342 |
dc.identifier.dark.fl_str_mv |
ark:/48912/001300000j2bn |
url |
http://dx.doi.org/10.1590/S0004-27492008000200016 http://repositorio.unifesp.br/handle/11600/4342 |
identifier_str_mv |
Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 71, n. 2, p. 221-227, 2008. 10.1590/S0004-27492008000200016 S0004-27492008000200016.pdf 0004-2749 S0004-27492008000200016 ark:/48912/001300000j2bn |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
221-227 application/pdf |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UNIFESP instname:Universidade Federal de São Paulo (UNIFESP) instacron:UNIFESP |
instname_str |
Universidade Federal de São Paulo (UNIFESP) |
instacron_str |
UNIFESP |
institution |
UNIFESP |
reponame_str |
Repositório Institucional da UNIFESP |
collection |
Repositório Institucional da UNIFESP |
repository.name.fl_str_mv |
Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP) |
repository.mail.fl_str_mv |
biblioteca.csp@unifesp.br |
_version_ |
1822219212616105984 |
dc.identifier.doi.none.fl_str_mv |
10.1590/S0004-27492008000200016 |