Autologous grafting of extraocular muscles: experimental study in rabbits
Autor(a) principal: | |
---|---|
Data de Publicação: | 2005 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNIFESP |
Texto Completo: | http://dx.doi.org/10.1590/S0004-27492005000300004 http://repositorio.unifesp.br/handle/11600/2560 |
Resumo: | PURPOSE: To evaluate the feasibility of autologous extraocular muscle grafting as a type of muscle expansion surgery. METHODS: The left superior rectus muscle of twenty-nine rabbits was resected and this fragment was attached to the endpoint of the respective right superior rectus (test group). Thereafter, the superior rectus of the left eye was reattached to the sclera (control group). Both groups were examined during different postoperative periods in order to assess their outcomes. RESULTS: The presence of hyperemia was slightly more frequent in the grafted group. Secretion and muscle atrophy were negligible in both groups. Fibrosis was greater in grafted animals. These muscles were weaker than the control muscles, although the force required to split muscular parts was always greater than the physiological one. CONCLUSIONS: This surgical technique was reliable and useful if one intends to achieve muscle expansion without the intrinsic risks of dealing with heterologous/artificial materials. |
id |
UFSP_0a7402f57bd8706691b2668fa97b3ce3 |
---|---|
oai_identifier_str |
oai:repositorio.unifesp.br/:11600/2560 |
network_acronym_str |
UFSP |
network_name_str |
Repositório Institucional da UNIFESP |
repository_id_str |
3465 |
spelling |
Autologous grafting of extraocular muscles: experimental study in rabbitsTransplante autólogo de musculatura ocular extrínseca: estudo experimental em coelhosEsotropiaOculomotor musclesTransplantationautologousOphthalmologic surgical proceduresRabbitsEsotropiaMúsculos oculomotoresTransplante autólogoProcedimentos cirúrgicos oftalmológicosCoelhosPURPOSE: To evaluate the feasibility of autologous extraocular muscle grafting as a type of muscle expansion surgery. METHODS: The left superior rectus muscle of twenty-nine rabbits was resected and this fragment was attached to the endpoint of the respective right superior rectus (test group). Thereafter, the superior rectus of the left eye was reattached to the sclera (control group). Both groups were examined during different postoperative periods in order to assess their outcomes. RESULTS: The presence of hyperemia was slightly more frequent in the grafted group. Secretion and muscle atrophy were negligible in both groups. Fibrosis was greater in grafted animals. These muscles were weaker than the control muscles, although the force required to split muscular parts was always greater than the physiological one. CONCLUSIONS: This surgical technique was reliable and useful if one intends to achieve muscle expansion without the intrinsic risks of dealing with heterologous/artificial materials.OBJETIVO: Avaliar a viabilidade do uso de segmentos de músculos oculares extrínsecos como expansores de tendões musculares. MÉTODOS: Vinte e nove coelhos tiveram seu músculo reto superior esquerdo ressecado e o fragmento de cada um foi transplantado para o reto superior contralateral (grupo-teste). Então, o reto superior esquerdo foi reinserido na esclera (grupo-controle). Os animais foram então examinados em diversos períodos pós-operatórios, até os seus sacrifícios, para que se avaliasse o desenrolar dessa técnica cirúrgica. RESULTADOS: A hiperemia foi maior entre os testes. A secreção e a atrofia muscular foram mínimas nos dois grupos. Houve maior presença de fibrose no grupo-teste, mas não tão expressiva a ponto de inviabilizar os efeitos da cirurgia. Esses músculos também se romperam mais facilmente do que os do grupo-controle, porém, a força de rompimento foi sempre bem maior do que aquela presente numa contração muscular normal. CONCLUSÕES: A técnica de transplante autólogo homotópico de músculos oculares extrínsecos provou ser confiável e eficaz, para o alongamento muscular.Universidade Federal de São Paulo (UNIFESP) setor de EstrabismoUniversidade de São Paulo Medicina de Ribeirão Preto Departamento de Oftalmologia, Otorrinolaringologia e Cirurgia da Cabeça e PescoçoUNIFESP, setor de EstrabismoSciELOConselho Brasileiro de OftalmologiaUniversidade Federal de São Paulo (UNIFESP)Universidade de São Paulo (USP)Meireles-teixeira, Jorge [UNIFESP]Bicas, Harley E. A.2015-06-14T13:31:37Z2015-06-14T13:31:37Z2005-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion295-297application/pdfhttp://dx.doi.org/10.1590/S0004-27492005000300004Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 68, n. 3, p. 295-297, 2005.10.1590/S0004-27492005000300004S0004-27492005000300004.pdf0004-2749S0004-27492005000300004http://repositorio.unifesp.br/handle/11600/2560engArquivos Brasileiros de Oftalmologiainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-07-28T08:46:38Zoai:repositorio.unifesp.br/:11600/2560Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-07-28T08:46:38Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false |
dc.title.none.fl_str_mv |
Autologous grafting of extraocular muscles: experimental study in rabbits Transplante autólogo de musculatura ocular extrínseca: estudo experimental em coelhos |
title |
Autologous grafting of extraocular muscles: experimental study in rabbits |
spellingShingle |
Autologous grafting of extraocular muscles: experimental study in rabbits Meireles-teixeira, Jorge [UNIFESP] Esotropia Oculomotor muscles Transplantation autologous Ophthalmologic surgical procedures Rabbits Esotropia Músculos oculomotores Transplante autólogo Procedimentos cirúrgicos oftalmológicos Coelhos |
title_short |
Autologous grafting of extraocular muscles: experimental study in rabbits |
title_full |
Autologous grafting of extraocular muscles: experimental study in rabbits |
title_fullStr |
Autologous grafting of extraocular muscles: experimental study in rabbits |
title_full_unstemmed |
Autologous grafting of extraocular muscles: experimental study in rabbits |
title_sort |
Autologous grafting of extraocular muscles: experimental study in rabbits |
author |
Meireles-teixeira, Jorge [UNIFESP] |
author_facet |
Meireles-teixeira, Jorge [UNIFESP] Bicas, Harley E. A. |
author_role |
author |
author2 |
Bicas, Harley E. A. |
author2_role |
author |
dc.contributor.none.fl_str_mv |
Universidade Federal de São Paulo (UNIFESP) Universidade de São Paulo (USP) |
dc.contributor.author.fl_str_mv |
Meireles-teixeira, Jorge [UNIFESP] Bicas, Harley E. A. |
dc.subject.por.fl_str_mv |
Esotropia Oculomotor muscles Transplantation autologous Ophthalmologic surgical procedures Rabbits Esotropia Músculos oculomotores Transplante autólogo Procedimentos cirúrgicos oftalmológicos Coelhos |
topic |
Esotropia Oculomotor muscles Transplantation autologous Ophthalmologic surgical procedures Rabbits Esotropia Músculos oculomotores Transplante autólogo Procedimentos cirúrgicos oftalmológicos Coelhos |
description |
PURPOSE: To evaluate the feasibility of autologous extraocular muscle grafting as a type of muscle expansion surgery. METHODS: The left superior rectus muscle of twenty-nine rabbits was resected and this fragment was attached to the endpoint of the respective right superior rectus (test group). Thereafter, the superior rectus of the left eye was reattached to the sclera (control group). Both groups were examined during different postoperative periods in order to assess their outcomes. RESULTS: The presence of hyperemia was slightly more frequent in the grafted group. Secretion and muscle atrophy were negligible in both groups. Fibrosis was greater in grafted animals. These muscles were weaker than the control muscles, although the force required to split muscular parts was always greater than the physiological one. CONCLUSIONS: This surgical technique was reliable and useful if one intends to achieve muscle expansion without the intrinsic risks of dealing with heterologous/artificial materials. |
publishDate |
2005 |
dc.date.none.fl_str_mv |
2005-06-01 2015-06-14T13:31:37Z 2015-06-14T13:31:37Z |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/S0004-27492005000300004 Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 68, n. 3, p. 295-297, 2005. 10.1590/S0004-27492005000300004 S0004-27492005000300004.pdf 0004-2749 S0004-27492005000300004 http://repositorio.unifesp.br/handle/11600/2560 |
url |
http://dx.doi.org/10.1590/S0004-27492005000300004 http://repositorio.unifesp.br/handle/11600/2560 |
identifier_str_mv |
Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 68, n. 3, p. 295-297, 2005. 10.1590/S0004-27492005000300004 S0004-27492005000300004.pdf 0004-2749 S0004-27492005000300004 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
295-297 application/pdf |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UNIFESP instname:Universidade Federal de São Paulo (UNIFESP) instacron:UNIFESP |
instname_str |
Universidade Federal de São Paulo (UNIFESP) |
instacron_str |
UNIFESP |
institution |
UNIFESP |
reponame_str |
Repositório Institucional da UNIFESP |
collection |
Repositório Institucional da UNIFESP |
repository.name.fl_str_mv |
Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP) |
repository.mail.fl_str_mv |
biblioteca.csp@unifesp.br |
_version_ |
1814268354504949760 |