Autologous grafting of extraocular muscles: experimental study in rabbits

Detalhes bibliográficos
Autor(a) principal: Meireles-teixeira, Jorge [UNIFESP]
Data de Publicação: 2005
Outros Autores: Bicas, Harley E. A.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.1590/S0004-27492005000300004
http://repositorio.unifesp.br/handle/11600/2560
Resumo: PURPOSE: To evaluate the feasibility of autologous extraocular muscle grafting as a type of muscle expansion surgery. METHODS: The left superior rectus muscle of twenty-nine rabbits was resected and this fragment was attached to the endpoint of the respective right superior rectus (test group). Thereafter, the superior rectus of the left eye was reattached to the sclera (control group). Both groups were examined during different postoperative periods in order to assess their outcomes. RESULTS: The presence of hyperemia was slightly more frequent in the grafted group. Secretion and muscle atrophy were negligible in both groups. Fibrosis was greater in grafted animals. These muscles were weaker than the control muscles, although the force required to split muscular parts was always greater than the physiological one. CONCLUSIONS: This surgical technique was reliable and useful if one intends to achieve muscle expansion without the intrinsic risks of dealing with heterologous/artificial materials.
id UFSP_0a7402f57bd8706691b2668fa97b3ce3
oai_identifier_str oai:repositorio.unifesp.br/:11600/2560
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Autologous grafting of extraocular muscles: experimental study in rabbitsTransplante autólogo de musculatura ocular extrínseca: estudo experimental em coelhosEsotropiaOculomotor musclesTransplantationautologousOphthalmologic surgical proceduresRabbitsEsotropiaMúsculos oculomotoresTransplante autólogoProcedimentos cirúrgicos oftalmológicosCoelhosPURPOSE: To evaluate the feasibility of autologous extraocular muscle grafting as a type of muscle expansion surgery. METHODS: The left superior rectus muscle of twenty-nine rabbits was resected and this fragment was attached to the endpoint of the respective right superior rectus (test group). Thereafter, the superior rectus of the left eye was reattached to the sclera (control group). Both groups were examined during different postoperative periods in order to assess their outcomes. RESULTS: The presence of hyperemia was slightly more frequent in the grafted group. Secretion and muscle atrophy were negligible in both groups. Fibrosis was greater in grafted animals. These muscles were weaker than the control muscles, although the force required to split muscular parts was always greater than the physiological one. CONCLUSIONS: This surgical technique was reliable and useful if one intends to achieve muscle expansion without the intrinsic risks of dealing with heterologous/artificial materials.OBJETIVO: Avaliar a viabilidade do uso de segmentos de músculos oculares extrínsecos como expansores de tendões musculares. MÉTODOS: Vinte e nove coelhos tiveram seu músculo reto superior esquerdo ressecado e o fragmento de cada um foi transplantado para o reto superior contralateral (grupo-teste). Então, o reto superior esquerdo foi reinserido na esclera (grupo-controle). Os animais foram então examinados em diversos períodos pós-operatórios, até os seus sacrifícios, para que se avaliasse o desenrolar dessa técnica cirúrgica. RESULTADOS: A hiperemia foi maior entre os testes. A secreção e a atrofia muscular foram mínimas nos dois grupos. Houve maior presença de fibrose no grupo-teste, mas não tão expressiva a ponto de inviabilizar os efeitos da cirurgia. Esses músculos também se romperam mais facilmente do que os do grupo-controle, porém, a força de rompimento foi sempre bem maior do que aquela presente numa contração muscular normal. CONCLUSÕES: A técnica de transplante autólogo homotópico de músculos oculares extrínsecos provou ser confiável e eficaz, para o alongamento muscular.Universidade Federal de São Paulo (UNIFESP) setor de EstrabismoUniversidade de São Paulo Medicina de Ribeirão Preto Departamento de Oftalmologia, Otorrinolaringologia e Cirurgia da Cabeça e PescoçoUNIFESP, setor de EstrabismoSciELOConselho Brasileiro de OftalmologiaUniversidade Federal de São Paulo (UNIFESP)Universidade de São Paulo (USP)Meireles-teixeira, Jorge [UNIFESP]Bicas, Harley E. A.2015-06-14T13:31:37Z2015-06-14T13:31:37Z2005-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion295-297application/pdfhttp://dx.doi.org/10.1590/S0004-27492005000300004Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 68, n. 3, p. 295-297, 2005.10.1590/S0004-27492005000300004S0004-27492005000300004.pdf0004-2749S0004-27492005000300004http://repositorio.unifesp.br/handle/11600/2560engArquivos Brasileiros de Oftalmologiainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-07-28T08:46:38Zoai:repositorio.unifesp.br/:11600/2560Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-07-28T08:46:38Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Autologous grafting of extraocular muscles: experimental study in rabbits
Transplante autólogo de musculatura ocular extrínseca: estudo experimental em coelhos
title Autologous grafting of extraocular muscles: experimental study in rabbits
spellingShingle Autologous grafting of extraocular muscles: experimental study in rabbits
Meireles-teixeira, Jorge [UNIFESP]
Esotropia
Oculomotor muscles
Transplantation
autologous
Ophthalmologic surgical procedures
Rabbits
Esotropia
Músculos oculomotores
Transplante autólogo
Procedimentos cirúrgicos oftalmológicos
Coelhos
title_short Autologous grafting of extraocular muscles: experimental study in rabbits
title_full Autologous grafting of extraocular muscles: experimental study in rabbits
title_fullStr Autologous grafting of extraocular muscles: experimental study in rabbits
title_full_unstemmed Autologous grafting of extraocular muscles: experimental study in rabbits
title_sort Autologous grafting of extraocular muscles: experimental study in rabbits
author Meireles-teixeira, Jorge [UNIFESP]
author_facet Meireles-teixeira, Jorge [UNIFESP]
Bicas, Harley E. A.
author_role author
author2 Bicas, Harley E. A.
author2_role author
dc.contributor.none.fl_str_mv Universidade Federal de São Paulo (UNIFESP)
Universidade de São Paulo (USP)
dc.contributor.author.fl_str_mv Meireles-teixeira, Jorge [UNIFESP]
Bicas, Harley E. A.
dc.subject.por.fl_str_mv Esotropia
Oculomotor muscles
Transplantation
autologous
Ophthalmologic surgical procedures
Rabbits
Esotropia
Músculos oculomotores
Transplante autólogo
Procedimentos cirúrgicos oftalmológicos
Coelhos
topic Esotropia
Oculomotor muscles
Transplantation
autologous
Ophthalmologic surgical procedures
Rabbits
Esotropia
Músculos oculomotores
Transplante autólogo
Procedimentos cirúrgicos oftalmológicos
Coelhos
description PURPOSE: To evaluate the feasibility of autologous extraocular muscle grafting as a type of muscle expansion surgery. METHODS: The left superior rectus muscle of twenty-nine rabbits was resected and this fragment was attached to the endpoint of the respective right superior rectus (test group). Thereafter, the superior rectus of the left eye was reattached to the sclera (control group). Both groups were examined during different postoperative periods in order to assess their outcomes. RESULTS: The presence of hyperemia was slightly more frequent in the grafted group. Secretion and muscle atrophy were negligible in both groups. Fibrosis was greater in grafted animals. These muscles were weaker than the control muscles, although the force required to split muscular parts was always greater than the physiological one. CONCLUSIONS: This surgical technique was reliable and useful if one intends to achieve muscle expansion without the intrinsic risks of dealing with heterologous/artificial materials.
publishDate 2005
dc.date.none.fl_str_mv 2005-06-01
2015-06-14T13:31:37Z
2015-06-14T13:31:37Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S0004-27492005000300004
Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 68, n. 3, p. 295-297, 2005.
10.1590/S0004-27492005000300004
S0004-27492005000300004.pdf
0004-2749
S0004-27492005000300004
http://repositorio.unifesp.br/handle/11600/2560
url http://dx.doi.org/10.1590/S0004-27492005000300004
http://repositorio.unifesp.br/handle/11600/2560
identifier_str_mv Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 68, n. 3, p. 295-297, 2005.
10.1590/S0004-27492005000300004
S0004-27492005000300004.pdf
0004-2749
S0004-27492005000300004
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Arquivos Brasileiros de Oftalmologia
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 295-297
application/pdf
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268354504949760