Noise at the Neonatal Intensive Care Unit and inside the incubator
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNIFESP |
dARK ID: | ark:/48912/001300000zpqn |
Texto Completo: | http://dx.doi.org/10.1590/S0104-11692011000500020 http://repositorio.unifesp.br/handle/11600/6654 |
Resumo: | The goal was to identify sound pressure level (SPL) at the neonatal intensive care unit (NICU) and inside the incubator of a teaching hospital of a public university from São Paulo - SP, Brazil. SPL inside the NICU and the incubator were measured using four dosimeters in January/2010. SPL at the NICU varied from 52.6 dBA to 80.4 dBA and inside the incubator, from 45.4 dBA to 79.1 dBA. SPL both at the NICU and inside the incubator are above the recommended values, but levels were higher at the NICU than inside the incubator. Although there are some specific factors related to SPL inside the incubator, the NICU and incubator acoustic features present a system: an increase/decrease in SPL at the NICU usually tends to increase/decrease SPL inside the incubator. The study points to the need for simultaneous monitoring of SPL at the NICU and inside the incubator. |
id |
UFSP_5561e51b7c377681f07590d5a6648a3d |
---|---|
oai_identifier_str |
oai:repositorio.unifesp.br/:11600/6654 |
network_acronym_str |
UFSP |
network_name_str |
Repositório Institucional da UNIFESP |
repository_id_str |
3465 |
spelling |
Noise at the Neonatal Intensive Care Unit and inside the incubatorRuido en la Unidad de Terapia Intensiva Neonatal y en el interior de la incubadoraRuído na Unidade de Terapia Intensiva Neonatal e no interior da incubadoraNoiseIntensive Care, NeonatalNeonatal NursingHumanization of AssistanceInfant, NewbornRuídoTerapia Intensiva NeonatalEnfermagem NeonatalHumanização da AssistênciaRecém-NascidoThe goal was to identify sound pressure level (SPL) at the neonatal intensive care unit (NICU) and inside the incubator of a teaching hospital of a public university from São Paulo - SP, Brazil. SPL inside the NICU and the incubator were measured using four dosimeters in January/2010. SPL at the NICU varied from 52.6 dBA to 80.4 dBA and inside the incubator, from 45.4 dBA to 79.1 dBA. SPL both at the NICU and inside the incubator are above the recommended values, but levels were higher at the NICU than inside the incubator. Although there are some specific factors related to SPL inside the incubator, the NICU and incubator acoustic features present a system: an increase/decrease in SPL at the NICU usually tends to increase/decrease SPL inside the incubator. The study points to the need for simultaneous monitoring of SPL at the NICU and inside the incubator.Se tuvo por objetivo identificar el nivel de presión sonora (NPS) de la Unidad de Terapia Intensiva Neonatal (UTIN) y del interior de la incubadora de un hospital escuela de una universidad pública de São Paulo-SP, Brasil. El NPS de la UTIN y de la incubadora fueron obtenidos por cuatro dosímetros en enero de 2010. El NPS de la UTIN varió entre 52,6 dBA y 80,4 dBA y el del interior de la incubadora fue de 45,4dBA a 79,1dBA. Tanto el NPS de la UTIN como el del interior de la incubadora son mayores que lo que recomendado, siendo más altos en la UTIN que en la incubadora. A pesar de que existen algunos factores específicos relacionados al NPS en el interior de la incubadora, los perfiles acústicos de la UTIN y de la incubadora son como un sistema, es decir: la elevación/reducción del NPS de la UTIN generalmente tiende a elevar/reducir el NPS en el interior de la incubadora. Se concluye que muy importante la monitorización simultánea del NPS de la UTIN y del interior de la incubadora.Este trabalho teve por objetivo identificar o nível de pressão sonora (NPS) da Unidade de Terapia Intensiva Neonatal (UTIN) e do interior da incubadora de um hospital escola de uma universidade pública de São Paulo, SP, Brasil. Como método para essa identificação, tanto do NPS da UTIN como do NPS da incubadora, foram utilizados quatro dosímetros, em janeiro de 2010. Os resultados obtidos apontam que o NPS da UTIN variou entre 52,6 dBA e 80,4 dBA, e que o NPS do interior da incubadora foi de 45,4dBA a 79,1dBA. Evidenciou-se que tanto o NPS da UTIN como o do interior da incubadora estão acima dos recomendados, sendo mais altos na UTIN do que na incubadora. Embora haja alguns fatores específicos relacionados ao NPS no interior da incubadora, perfis acústicos da UTIN e da incubadora são como sistema: elevação/redução do NPS da UTIN, geralmente, tende a elevar/reduzir o NPS no interior da incubadora. Portanto, pode-se concluir que o presente estudo aponta para a importância do monitoramento simultâneo dos NPS da UTIN e do interior da incubadora.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de EnfermagemUniversidade Federal de São Paulo (UNIFESP) Departamento de PediatriaInstituto Nacional de Metrologia, Normalização e Qualidade IndustrialUNIFESP, Escola Paulista de Enfermagem (EPE)UNIFESP, Depto. de PediatriaSciELOEscola de Enfermagem de Ribeirão Preto / Universidade de São PauloUniversidade Federal de São Paulo (UNIFESP)Instituto Nacional de Metrologia, Normalização e Qualidade IndustrialPinheiro, Eliana Moreira [UNIFESP]Guinsburg, Ruth [UNIFESP]Nabuco, Marco Antonio de AraujoKakehashi, Tereza Yoshiko [UNIFESP]2015-06-14T13:43:18Z2015-06-14T13:43:18Z2011-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion1214-1221application/pdfapplication/pdfapplication/pdfhttp://dx.doi.org/10.1590/S0104-11692011000500020PINHEIRO, Eliana Moreira et al . Noise at the Neonatal Intensive Care Unit and inside the incubator. Rev. Latino-Am. Enfermagem, Ribeirão Preto , v. 19, n. 5, p. 1214-1221, out. 201110.1590/S0104-11692011000500020S0104-11692011000500020.pdfS0104-11692011000500020-pt.pdfS0104-11692011000500020-es.pdf0104-1169S0104-11692011000500020http://repositorio.unifesp.br/handle/11600/6654WOS:000296374500020ark:/48912/001300000zpqnengRevista Latino-Americana de Enfermageminfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-07-28T23:28:44Zoai:repositorio.unifesp.br/:11600/6654Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-12-11T20:45:48.099369Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false |
dc.title.none.fl_str_mv |
Noise at the Neonatal Intensive Care Unit and inside the incubator Ruido en la Unidad de Terapia Intensiva Neonatal y en el interior de la incubadora Ruído na Unidade de Terapia Intensiva Neonatal e no interior da incubadora |
title |
Noise at the Neonatal Intensive Care Unit and inside the incubator |
spellingShingle |
Noise at the Neonatal Intensive Care Unit and inside the incubator Pinheiro, Eliana Moreira [UNIFESP] Noise Intensive Care, Neonatal Neonatal Nursing Humanization of Assistance Infant, Newborn Ruído Terapia Intensiva Neonatal Enfermagem Neonatal Humanização da Assistência Recém-Nascido |
title_short |
Noise at the Neonatal Intensive Care Unit and inside the incubator |
title_full |
Noise at the Neonatal Intensive Care Unit and inside the incubator |
title_fullStr |
Noise at the Neonatal Intensive Care Unit and inside the incubator |
title_full_unstemmed |
Noise at the Neonatal Intensive Care Unit and inside the incubator |
title_sort |
Noise at the Neonatal Intensive Care Unit and inside the incubator |
author |
Pinheiro, Eliana Moreira [UNIFESP] |
author_facet |
Pinheiro, Eliana Moreira [UNIFESP] Guinsburg, Ruth [UNIFESP] Nabuco, Marco Antonio de Araujo Kakehashi, Tereza Yoshiko [UNIFESP] |
author_role |
author |
author2 |
Guinsburg, Ruth [UNIFESP] Nabuco, Marco Antonio de Araujo Kakehashi, Tereza Yoshiko [UNIFESP] |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade Federal de São Paulo (UNIFESP) Instituto Nacional de Metrologia, Normalização e Qualidade Industrial |
dc.contributor.author.fl_str_mv |
Pinheiro, Eliana Moreira [UNIFESP] Guinsburg, Ruth [UNIFESP] Nabuco, Marco Antonio de Araujo Kakehashi, Tereza Yoshiko [UNIFESP] |
dc.subject.por.fl_str_mv |
Noise Intensive Care, Neonatal Neonatal Nursing Humanization of Assistance Infant, Newborn Ruído Terapia Intensiva Neonatal Enfermagem Neonatal Humanização da Assistência Recém-Nascido |
topic |
Noise Intensive Care, Neonatal Neonatal Nursing Humanization of Assistance Infant, Newborn Ruído Terapia Intensiva Neonatal Enfermagem Neonatal Humanização da Assistência Recém-Nascido |
description |
The goal was to identify sound pressure level (SPL) at the neonatal intensive care unit (NICU) and inside the incubator of a teaching hospital of a public university from São Paulo - SP, Brazil. SPL inside the NICU and the incubator were measured using four dosimeters in January/2010. SPL at the NICU varied from 52.6 dBA to 80.4 dBA and inside the incubator, from 45.4 dBA to 79.1 dBA. SPL both at the NICU and inside the incubator are above the recommended values, but levels were higher at the NICU than inside the incubator. Although there are some specific factors related to SPL inside the incubator, the NICU and incubator acoustic features present a system: an increase/decrease in SPL at the NICU usually tends to increase/decrease SPL inside the incubator. The study points to the need for simultaneous monitoring of SPL at the NICU and inside the incubator. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-10-01 2015-06-14T13:43:18Z 2015-06-14T13:43:18Z |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/S0104-11692011000500020 PINHEIRO, Eliana Moreira et al . Noise at the Neonatal Intensive Care Unit and inside the incubator. Rev. Latino-Am. Enfermagem, Ribeirão Preto , v. 19, n. 5, p. 1214-1221, out. 2011 10.1590/S0104-11692011000500020 S0104-11692011000500020.pdf S0104-11692011000500020-pt.pdf S0104-11692011000500020-es.pdf 0104-1169 S0104-11692011000500020 http://repositorio.unifesp.br/handle/11600/6654 WOS:000296374500020 |
dc.identifier.dark.fl_str_mv |
ark:/48912/001300000zpqn |
url |
http://dx.doi.org/10.1590/S0104-11692011000500020 http://repositorio.unifesp.br/handle/11600/6654 |
identifier_str_mv |
PINHEIRO, Eliana Moreira et al . Noise at the Neonatal Intensive Care Unit and inside the incubator. Rev. Latino-Am. Enfermagem, Ribeirão Preto , v. 19, n. 5, p. 1214-1221, out. 2011 10.1590/S0104-11692011000500020 S0104-11692011000500020.pdf S0104-11692011000500020-pt.pdf S0104-11692011000500020-es.pdf 0104-1169 S0104-11692011000500020 WOS:000296374500020 ark:/48912/001300000zpqn |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Revista Latino-Americana de Enfermagem |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
1214-1221 application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Escola de Enfermagem de Ribeirão Preto / Universidade de São Paulo |
publisher.none.fl_str_mv |
Escola de Enfermagem de Ribeirão Preto / Universidade de São Paulo |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UNIFESP instname:Universidade Federal de São Paulo (UNIFESP) instacron:UNIFESP |
instname_str |
Universidade Federal de São Paulo (UNIFESP) |
instacron_str |
UNIFESP |
institution |
UNIFESP |
reponame_str |
Repositório Institucional da UNIFESP |
collection |
Repositório Institucional da UNIFESP |
repository.name.fl_str_mv |
Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP) |
repository.mail.fl_str_mv |
biblioteca.csp@unifesp.br |
_version_ |
1818602540793593856 |