Repeatability of central corneal thickness measurement with the Pentacam HR system
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNIFESP |
dARK ID: | ark:/48912/001300000wp40 |
Texto Completo: | http://dx.doi.org/10.1590/S0034-72802012000100003 http://repositorio.unifesp.br/handle/11600/45369 |
Resumo: | Purpose: To assess the repeatability of central corneal thickness measurement at the geometrical center (Central Corneal Thickness - CCT) given by the Pentacam High Resolution (HR) Comprehensive Eye Scanner (Oculus, Wetzlar, Germany) over time. Methods: Prospective, single center, observational study. Two separate CCT measurements were taken by the Pentacam corneal tomography exam (CTm) 3 to 12 months apart, and compared. Results: One hundred and sixteen eyes (n=116) of 62 health patients were included in this study. Average CCT in first and last visits was 541.6 +/- 37 mu m and 543.6 +/- 36.9 mu m respectively. Mean difference between both measurements was 9.2 +/- 6.4 mu m, and there was no statistically significant difference in CCT measurement between visits, with good correlation between them (P = 0.057, r(2) = 0,9209). Conclusion: Pentacam (HR) CTm gives repeatable CCT measurements over time. |
id |
UFSP_899fca5ba4b9440e975b9ef54a797848 |
---|---|
oai_identifier_str |
oai:repositorio.unifesp.br/:11600/45369 |
network_acronym_str |
UFSP |
network_name_str |
Repositório Institucional da UNIFESP |
repository_id_str |
3465 |
spelling |
Repeatability of central corneal thickness measurement with the Pentacam HR systemReprodutibilidade da medida da espessura central da córnea com o sistema Pentacam HRCornea/anatomy & histologyCorneal topographyBiometry/methodsReproducibility of resultsDiagnostic techniques, ophthalmological/instrumentationPurpose: To assess the repeatability of central corneal thickness measurement at the geometrical center (Central Corneal Thickness - CCT) given by the Pentacam High Resolution (HR) Comprehensive Eye Scanner (Oculus, Wetzlar, Germany) over time. Methods: Prospective, single center, observational study. Two separate CCT measurements were taken by the Pentacam corneal tomography exam (CTm) 3 to 12 months apart, and compared. Results: One hundred and sixteen eyes (n=116) of 62 health patients were included in this study. Average CCT in first and last visits was 541.6 +/- 37 mu m and 543.6 +/- 36.9 mu m respectively. Mean difference between both measurements was 9.2 +/- 6.4 mu m, and there was no statistically significant difference in CCT measurement between visits, with good correlation between them (P = 0.057, r(2) = 0,9209). Conclusion: Pentacam (HR) CTm gives repeatable CCT measurements over time.Hosp Santa Casa Misericordia Rio de Janeiro RJ, Rio De Janeiro, BrazilUniv Fed Sao Paulo UNIFESP, Dept Oftalmol, Sao Paulo, BrazilHosp Univ Antonio Pedro, Niteroi, RJ, BrazilInst Olhos Renato Ambrosio, Rio De Janeiro, RJ, BrazilUniv Fed Fluminense, Rio De Janeiro, RJ, BrazilUniv Fed Sao Paulo UNIFESP, Dept Oftalmol, Sao Paulo, BrazilWeb of ScienceSoc Brasileira OftalmologiaHosp Santa Casa Misericordia Rio de Janeiro RJUniversidade Federal de São Paulo (UNIFESP)Hosp Univ Antonio PedroInst Olhos Renato AmbrosioUniversidade Federal Fluminense (UFF)Alonso, Ruiz SimonatoFontes, Bruno Machado [UNIFESP]Ventura, Marcelo PalisAmbrósio, Renato [UNIFESP]2018-06-18T11:43:56Z2018-06-18T11:43:56Z2012-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion14-17application/pdfhttp://dx.doi.org/10.1590/S0034-72802012000100003Revista Brasileira De Oftalmologia. Rio De Janeiro: Soc Brasileira Oftalmologia, v. 71, n. 1, p. 14-17, 2012.10.1590/S0034-72802012000100003S0034-72802012000100003.pdf0034-7280S0034-72802012000100003http://repositorio.unifesp.br/handle/11600/45369WOS:000301587800003ark:/48912/001300000wp40engRevista Brasileira De Oftalmologiainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-08-10T01:33:46Zoai:repositorio.unifesp.br/:11600/45369Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-12-11T20:41:50.166867Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false |
dc.title.none.fl_str_mv |
Repeatability of central corneal thickness measurement with the Pentacam HR system Reprodutibilidade da medida da espessura central da córnea com o sistema Pentacam HR |
title |
Repeatability of central corneal thickness measurement with the Pentacam HR system |
spellingShingle |
Repeatability of central corneal thickness measurement with the Pentacam HR system Alonso, Ruiz Simonato Cornea/anatomy & histology Corneal topography Biometry/methods Reproducibility of results Diagnostic techniques, ophthalmological/instrumentation |
title_short |
Repeatability of central corneal thickness measurement with the Pentacam HR system |
title_full |
Repeatability of central corneal thickness measurement with the Pentacam HR system |
title_fullStr |
Repeatability of central corneal thickness measurement with the Pentacam HR system |
title_full_unstemmed |
Repeatability of central corneal thickness measurement with the Pentacam HR system |
title_sort |
Repeatability of central corneal thickness measurement with the Pentacam HR system |
author |
Alonso, Ruiz Simonato |
author_facet |
Alonso, Ruiz Simonato Fontes, Bruno Machado [UNIFESP] Ventura, Marcelo Palis Ambrósio, Renato [UNIFESP] |
author_role |
author |
author2 |
Fontes, Bruno Machado [UNIFESP] Ventura, Marcelo Palis Ambrósio, Renato [UNIFESP] |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Hosp Santa Casa Misericordia Rio de Janeiro RJ Universidade Federal de São Paulo (UNIFESP) Hosp Univ Antonio Pedro Inst Olhos Renato Ambrosio Universidade Federal Fluminense (UFF) |
dc.contributor.author.fl_str_mv |
Alonso, Ruiz Simonato Fontes, Bruno Machado [UNIFESP] Ventura, Marcelo Palis Ambrósio, Renato [UNIFESP] |
dc.subject.por.fl_str_mv |
Cornea/anatomy & histology Corneal topography Biometry/methods Reproducibility of results Diagnostic techniques, ophthalmological/instrumentation |
topic |
Cornea/anatomy & histology Corneal topography Biometry/methods Reproducibility of results Diagnostic techniques, ophthalmological/instrumentation |
description |
Purpose: To assess the repeatability of central corneal thickness measurement at the geometrical center (Central Corneal Thickness - CCT) given by the Pentacam High Resolution (HR) Comprehensive Eye Scanner (Oculus, Wetzlar, Germany) over time. Methods: Prospective, single center, observational study. Two separate CCT measurements were taken by the Pentacam corneal tomography exam (CTm) 3 to 12 months apart, and compared. Results: One hundred and sixteen eyes (n=116) of 62 health patients were included in this study. Average CCT in first and last visits was 541.6 +/- 37 mu m and 543.6 +/- 36.9 mu m respectively. Mean difference between both measurements was 9.2 +/- 6.4 mu m, and there was no statistically significant difference in CCT measurement between visits, with good correlation between them (P = 0.057, r(2) = 0,9209). Conclusion: Pentacam (HR) CTm gives repeatable CCT measurements over time. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-01-01 2018-06-18T11:43:56Z 2018-06-18T11:43:56Z |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/S0034-72802012000100003 Revista Brasileira De Oftalmologia. Rio De Janeiro: Soc Brasileira Oftalmologia, v. 71, n. 1, p. 14-17, 2012. 10.1590/S0034-72802012000100003 S0034-72802012000100003.pdf 0034-7280 S0034-72802012000100003 http://repositorio.unifesp.br/handle/11600/45369 WOS:000301587800003 |
dc.identifier.dark.fl_str_mv |
ark:/48912/001300000wp40 |
url |
http://dx.doi.org/10.1590/S0034-72802012000100003 http://repositorio.unifesp.br/handle/11600/45369 |
identifier_str_mv |
Revista Brasileira De Oftalmologia. Rio De Janeiro: Soc Brasileira Oftalmologia, v. 71, n. 1, p. 14-17, 2012. 10.1590/S0034-72802012000100003 S0034-72802012000100003.pdf 0034-7280 S0034-72802012000100003 WOS:000301587800003 ark:/48912/001300000wp40 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Revista Brasileira De Oftalmologia |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
14-17 application/pdf |
dc.publisher.none.fl_str_mv |
Soc Brasileira Oftalmologia |
publisher.none.fl_str_mv |
Soc Brasileira Oftalmologia |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UNIFESP instname:Universidade Federal de São Paulo (UNIFESP) instacron:UNIFESP |
instname_str |
Universidade Federal de São Paulo (UNIFESP) |
instacron_str |
UNIFESP |
institution |
UNIFESP |
reponame_str |
Repositório Institucional da UNIFESP |
collection |
Repositório Institucional da UNIFESP |
repository.name.fl_str_mv |
Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP) |
repository.mail.fl_str_mv |
biblioteca.csp@unifesp.br |
_version_ |
1818602529813954560 |