Uso de espectrometria no infravermelho médio, calibração multivariada e seleção de variáveis por intervalos na quantificação de biodieseis em misturas com diesel

Detalhes bibliográficos
Autor(a) principal: Gontijo, Lucas Caixeta
Data de Publicação: 2016
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFU
Texto Completo: https://repositorio.ufu.br/handle/123456789/17536
https://doi.org/10.14393/ufu.te.2016.47
Resumo: In Brazil, since November 2014, it is required by law an addition of 7% (v/v) of biodiesel to diesel, and this mixture is called B7. According to the report issued by National Brazilian Agency of Petroleum, Natural Gas and Biofuels in 2015, 33.6% of commercial diesel samples examined presented biodiesel content outside quality specifications. Therefore, this work aims to develop and validate methodologies to quantify methyl and ethyl biodiesel from soybeans, used frying oil, cottonseed and jatropha into binary mixtures with diesel, using Mid Infrared Spectroscopy (680 to 3100 cm-1) and multivariate calibration by Partial Least Squares (PLS). Furthermore, we present a study of application of variable selection methods for intervals as Interval Partial Least Squares (iPLS), Backward Interval Partial Least Squares (biPLS) and Synergy Interval Partial Least Squares (siPLS). Thus, the models built from spectral intervals, which provided, statistically, lower Root Mean Square Error of Prediction (RMSEP) and fewer variables compared to the model of full spectrum, were validated to determine the respective type of biodiesel mixed with diesel. The results of the global PLS models, to all kinds of biodiesels, demonstrated excellent correlation between actual and predicted values of the prediction set (R > 0.99), in the range of concentration of 1.00 to 30.00% (v/v), values of RSMEP between 0.0473 and 0.1020% (v/v) and did not show systematic errors according to ASTM E1655 norm. The proposed global PLS models met the requirements of accuracy demanded by ABNT NBR15568 (RMSEP < 0.1%) besides using only one calibration model against two of the respective norm. In relation to Variable Selection methods by intervals, were efficient in the elimination of non-informative variables significantly improving the prediction of validation samples if compared to multivariate calibration by PLS models, with the exception of the models containing biodiesels from used frying oil and jatropha methyl biodiesel. Therefore, the developed methodologies are presented as a viable alternative to the usual analysis for determining the biodiesel content in mixtures as diesel.
id UFU_dde845121975fa154ff910028beda00b
oai_identifier_str oai:repositorio.ufu.br:123456789/17536
network_acronym_str UFU
network_name_str Repositório Institucional da UFU
repository_id_str
spelling 2016-06-22T18:49:03Z2016-05-052016-06-22T18:49:03Z2016-03-18GONTIJO, Lucas Caixeta. Uso de espectrometria no infravermelho médio, calibração multivariada e seleção de variáveis por intervalos na quantificação de biodieseis em misturas com diesel. 2016. 106 f. Tese (Doutorado em Ciências Exatas e da Terra) - Universidade Federal de Uberlândia, Uberlândia, 2016. Disponível em: https://doi.org/10.14393/ufu.te.2016.47https://repositorio.ufu.br/handle/123456789/17536https://doi.org/10.14393/ufu.te.2016.47In Brazil, since November 2014, it is required by law an addition of 7% (v/v) of biodiesel to diesel, and this mixture is called B7. According to the report issued by National Brazilian Agency of Petroleum, Natural Gas and Biofuels in 2015, 33.6% of commercial diesel samples examined presented biodiesel content outside quality specifications. Therefore, this work aims to develop and validate methodologies to quantify methyl and ethyl biodiesel from soybeans, used frying oil, cottonseed and jatropha into binary mixtures with diesel, using Mid Infrared Spectroscopy (680 to 3100 cm-1) and multivariate calibration by Partial Least Squares (PLS). Furthermore, we present a study of application of variable selection methods for intervals as Interval Partial Least Squares (iPLS), Backward Interval Partial Least Squares (biPLS) and Synergy Interval Partial Least Squares (siPLS). Thus, the models built from spectral intervals, which provided, statistically, lower Root Mean Square Error of Prediction (RMSEP) and fewer variables compared to the model of full spectrum, were validated to determine the respective type of biodiesel mixed with diesel. The results of the global PLS models, to all kinds of biodiesels, demonstrated excellent correlation between actual and predicted values of the prediction set (R > 0.99), in the range of concentration of 1.00 to 30.00% (v/v), values of RSMEP between 0.0473 and 0.1020% (v/v) and did not show systematic errors according to ASTM E1655 norm. The proposed global PLS models met the requirements of accuracy demanded by ABNT NBR15568 (RMSEP < 0.1%) besides using only one calibration model against two of the respective norm. In relation to Variable Selection methods by intervals, were efficient in the elimination of non-informative variables significantly improving the prediction of validation samples if compared to multivariate calibration by PLS models, with the exception of the models containing biodiesels from used frying oil and jatropha methyl biodiesel. Therefore, the developed methodologies are presented as a viable alternative to the usual analysis for determining the biodiesel content in mixtures as diesel.No Brasil, a partir de novembro de 2014, é exigido por lei a adição de 7% (v/v) de biodiesel ao diesel sendo esta mistura denominada de B7. De acordo com o boletim emitido pela Agência Nacional de Petróleo, Gás Natural e Biocombustíveis, em 2015, 33,6% do total das amostras de diesel comercial analisadas apresentaram teor de biodiesel fora das especificações de qualidade. Assim, o presente estudo teve por objetivo desenvolver e validar metodologias para quantificar biodieseis metílicos e etílicos, provenientes de óleos de soja, fritura usado, algodão e pinhão manso, em misturas binárias com diesel, empregando a técnica de Espectrometria no Infravermelho Médio (680 a 3100 cm-1) e calibração multivariada por Quadrados Mínimos Parciais (PLS). Além disso, apresenta um estudo da aplicação de métodos de seleção de variáveis por intervalos como os Quadrados Mínimos Parciais por Intervalos (iPLS), Quadrados Mínimos Parciais por Exclusão de Intervalos (biPLS) e Quadrados Mínimos Parciais por Intervalos Sinérgicos (siPLS). Desta maneira, os modelos construídos a partir dos intervalos espectrais que proporcionaram, estatisticamente, menor valor de Erro Quadrático Médio de Previsão (RMSEP) e menor número de variáveis, em comparação ao modelo de espectro total, foram validados para determinação do respectivo tipo de biodiesel em mistura com diesel. Os resultados dos modelos PLS global, para todos os tipos de biodieseis, demonstram excelente correlação entre os valores reais e previstos do conjunto de previsão (R > 0,99), na faixa de concentração de 1,00 a 30,00% (v/v), valores de RMSEP entre 0,0473 e 0,1020% (v/v) e não apresentaram erros sistemáticos conforme a norma ASTM E1655. Os modelos PLS global propostos atenderam as exigências de exatidão requerida pela ABNT NBR15568 (RMSEP < 0,1%) além de utilizar apenas um modelo de calibração contra dois da respectiva norma. Em relação aos métodos de seleção de variáveis por intervalos estes foram eficientes na eliminação de variáveis não informativas melhorando significativamente a previsão de amostras de validação, se comparado ao desempenho do modelo de calibração multivariada por PLS, com exceção aos modelos contendo biodieseis provenientes de óleo de fritura usado e biodiesel metílico de pinhão manso. Portanto, as metodologias desenvolvidas apresentam como uma alternativa viável às análises usuais para a determinação do teor de biodiesel em misturas com diesel.Coordenação de Aperfeiçoamento de Pessoal de Nível SuperiorDoutor em Químicaapplication/pdfporUniversidade Federal de UberlândiaPrograma de Pós-graduação Multi-Institucional em Quimica (UFG - UFMS - UFU)UFUBRCiências Exatas e da TerraBiodieselInfravermelhoCalibração multivariadaPLSiPLSSeleção de variáveisEspectroscopia de infravermelhoCalibraçãoInfraredMultivariate calibrationVariable selectionCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICAUso de espectrometria no infravermelho médio, calibração multivariada e seleção de variáveis por intervalos na quantificação de biodieseis em misturas com dieselinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisBorges Neto, Waldomirohttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4701146T6Souza, Paulo Sérgio dehttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4789440T0Bruns, Roy Edwardhttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4788955J7Trovó, Alam Gustavohttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4770357Z6Batista, Alex Domingueshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4256613E7http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4774720P5Gontijo, Lucas Caixetainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFUinstname:Universidade Federal de Uberlândia (UFU)instacron:UFUTHUMBNAILUsoEspectrometriaInfravermelhoMedio.pdf.jpgUsoEspectrometriaInfravermelhoMedio.pdf.jpgGenerated Thumbnailimage/jpeg1415https://repositorio.ufu.br/bitstream/123456789/17536/3/UsoEspectrometriaInfravermelhoMedio.pdf.jpg90830fbb647c5d5308bc56dcd33d2310MD53ORIGINALUsoEspectrometriaInfravermelhoMedio.pdfapplication/pdf4835875https://repositorio.ufu.br/bitstream/123456789/17536/1/UsoEspectrometriaInfravermelhoMedio.pdfcbeaf54485dc3c06b0a029395adae442MD51TEXTUsoEspectrometriaInfravermelhoMedio.pdf.txtUsoEspectrometriaInfravermelhoMedio.pdf.txtExtracted texttext/plain162501https://repositorio.ufu.br/bitstream/123456789/17536/2/UsoEspectrometriaInfravermelhoMedio.pdf.txt98069aa09f45ee23e332230610e55beeMD52123456789/175362020-09-16 19:38:37.137oai:repositorio.ufu.br:123456789/17536Repositório InstitucionalONGhttp://repositorio.ufu.br/oai/requestdiinf@dirbi.ufu.bropendoar:2020-09-16T22:38:37Repositório Institucional da UFU - Universidade Federal de Uberlândia (UFU)false
dc.title.por.fl_str_mv Uso de espectrometria no infravermelho médio, calibração multivariada e seleção de variáveis por intervalos na quantificação de biodieseis em misturas com diesel
title Uso de espectrometria no infravermelho médio, calibração multivariada e seleção de variáveis por intervalos na quantificação de biodieseis em misturas com diesel
spellingShingle Uso de espectrometria no infravermelho médio, calibração multivariada e seleção de variáveis por intervalos na quantificação de biodieseis em misturas com diesel
Gontijo, Lucas Caixeta
Biodiesel
Infravermelho
Calibração multivariada
PLS
iPLS
Seleção de variáveis
Espectroscopia de infravermelho
Calibração
Infrared
Multivariate calibration
Variable selection
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
title_short Uso de espectrometria no infravermelho médio, calibração multivariada e seleção de variáveis por intervalos na quantificação de biodieseis em misturas com diesel
title_full Uso de espectrometria no infravermelho médio, calibração multivariada e seleção de variáveis por intervalos na quantificação de biodieseis em misturas com diesel
title_fullStr Uso de espectrometria no infravermelho médio, calibração multivariada e seleção de variáveis por intervalos na quantificação de biodieseis em misturas com diesel
title_full_unstemmed Uso de espectrometria no infravermelho médio, calibração multivariada e seleção de variáveis por intervalos na quantificação de biodieseis em misturas com diesel
title_sort Uso de espectrometria no infravermelho médio, calibração multivariada e seleção de variáveis por intervalos na quantificação de biodieseis em misturas com diesel
author Gontijo, Lucas Caixeta
author_facet Gontijo, Lucas Caixeta
author_role author
dc.contributor.advisor1.fl_str_mv Borges Neto, Waldomiro
dc.contributor.advisor1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4701146T6
dc.contributor.referee1.fl_str_mv Souza, Paulo Sérgio de
dc.contributor.referee1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4789440T0
dc.contributor.referee2.fl_str_mv Bruns, Roy Edward
dc.contributor.referee2Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4788955J7
dc.contributor.referee3.fl_str_mv Trovó, Alam Gustavo
dc.contributor.referee3Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4770357Z6
dc.contributor.referee4.fl_str_mv Batista, Alex Domingues
dc.contributor.referee4Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4256613E7
dc.contributor.authorLattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4774720P5
dc.contributor.author.fl_str_mv Gontijo, Lucas Caixeta
contributor_str_mv Borges Neto, Waldomiro
Souza, Paulo Sérgio de
Bruns, Roy Edward
Trovó, Alam Gustavo
Batista, Alex Domingues
dc.subject.por.fl_str_mv Biodiesel
Infravermelho
Calibração multivariada
PLS
iPLS
Seleção de variáveis
Espectroscopia de infravermelho
Calibração
topic Biodiesel
Infravermelho
Calibração multivariada
PLS
iPLS
Seleção de variáveis
Espectroscopia de infravermelho
Calibração
Infrared
Multivariate calibration
Variable selection
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
dc.subject.eng.fl_str_mv Infrared
Multivariate calibration
Variable selection
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
description In Brazil, since November 2014, it is required by law an addition of 7% (v/v) of biodiesel to diesel, and this mixture is called B7. According to the report issued by National Brazilian Agency of Petroleum, Natural Gas and Biofuels in 2015, 33.6% of commercial diesel samples examined presented biodiesel content outside quality specifications. Therefore, this work aims to develop and validate methodologies to quantify methyl and ethyl biodiesel from soybeans, used frying oil, cottonseed and jatropha into binary mixtures with diesel, using Mid Infrared Spectroscopy (680 to 3100 cm-1) and multivariate calibration by Partial Least Squares (PLS). Furthermore, we present a study of application of variable selection methods for intervals as Interval Partial Least Squares (iPLS), Backward Interval Partial Least Squares (biPLS) and Synergy Interval Partial Least Squares (siPLS). Thus, the models built from spectral intervals, which provided, statistically, lower Root Mean Square Error of Prediction (RMSEP) and fewer variables compared to the model of full spectrum, were validated to determine the respective type of biodiesel mixed with diesel. The results of the global PLS models, to all kinds of biodiesels, demonstrated excellent correlation between actual and predicted values of the prediction set (R > 0.99), in the range of concentration of 1.00 to 30.00% (v/v), values of RSMEP between 0.0473 and 0.1020% (v/v) and did not show systematic errors according to ASTM E1655 norm. The proposed global PLS models met the requirements of accuracy demanded by ABNT NBR15568 (RMSEP < 0.1%) besides using only one calibration model against two of the respective norm. In relation to Variable Selection methods by intervals, were efficient in the elimination of non-informative variables significantly improving the prediction of validation samples if compared to multivariate calibration by PLS models, with the exception of the models containing biodiesels from used frying oil and jatropha methyl biodiesel. Therefore, the developed methodologies are presented as a viable alternative to the usual analysis for determining the biodiesel content in mixtures as diesel.
publishDate 2016
dc.date.accessioned.fl_str_mv 2016-06-22T18:49:03Z
dc.date.available.fl_str_mv 2016-05-05
2016-06-22T18:49:03Z
dc.date.issued.fl_str_mv 2016-03-18
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv GONTIJO, Lucas Caixeta. Uso de espectrometria no infravermelho médio, calibração multivariada e seleção de variáveis por intervalos na quantificação de biodieseis em misturas com diesel. 2016. 106 f. Tese (Doutorado em Ciências Exatas e da Terra) - Universidade Federal de Uberlândia, Uberlândia, 2016. Disponível em: https://doi.org/10.14393/ufu.te.2016.47
dc.identifier.uri.fl_str_mv https://repositorio.ufu.br/handle/123456789/17536
dc.identifier.doi.pt_BR.fl_str_mv https://doi.org/10.14393/ufu.te.2016.47
identifier_str_mv GONTIJO, Lucas Caixeta. Uso de espectrometria no infravermelho médio, calibração multivariada e seleção de variáveis por intervalos na quantificação de biodieseis em misturas com diesel. 2016. 106 f. Tese (Doutorado em Ciências Exatas e da Terra) - Universidade Federal de Uberlândia, Uberlândia, 2016. Disponível em: https://doi.org/10.14393/ufu.te.2016.47
url https://repositorio.ufu.br/handle/123456789/17536
https://doi.org/10.14393/ufu.te.2016.47
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Uberlândia
dc.publisher.program.fl_str_mv Programa de Pós-graduação Multi-Institucional em Quimica (UFG - UFMS - UFU)
dc.publisher.initials.fl_str_mv UFU
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Ciências Exatas e da Terra
publisher.none.fl_str_mv Universidade Federal de Uberlândia
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFU
instname:Universidade Federal de Uberlândia (UFU)
instacron:UFU
instname_str Universidade Federal de Uberlândia (UFU)
instacron_str UFU
institution UFU
reponame_str Repositório Institucional da UFU
collection Repositório Institucional da UFU
bitstream.url.fl_str_mv https://repositorio.ufu.br/bitstream/123456789/17536/3/UsoEspectrometriaInfravermelhoMedio.pdf.jpg
https://repositorio.ufu.br/bitstream/123456789/17536/1/UsoEspectrometriaInfravermelhoMedio.pdf
https://repositorio.ufu.br/bitstream/123456789/17536/2/UsoEspectrometriaInfravermelhoMedio.pdf.txt
bitstream.checksum.fl_str_mv 90830fbb647c5d5308bc56dcd33d2310
cbeaf54485dc3c06b0a029395adae442
98069aa09f45ee23e332230610e55bee
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFU - Universidade Federal de Uberlândia (UFU)
repository.mail.fl_str_mv diinf@dirbi.ufu.br
_version_ 1802110521173868544