Thermal load calculation of an industrialized açaí freezing tunnel with a capacity of 20 tons

Detalhes bibliográficos
Autor(a) principal: Pereira, Marcos Duran
Data de Publicação: 2022
Outros Autores: Siqueira, Antonio Marcos de Oliveira
Tipo de documento: Artigo
Idioma: por
Título da fonte: Revista de Engenharia Química e Química
Texto Completo: https://periodicos.ufv.br/jcec/article/view/14190
Resumo: Açaí is a fruit native to the Amazon region that is important as a source of food and for a local culture and that has become popular nationally in the most recent decades, already reaching international markets. The freezing process is used to delay the deterioration of food, preserving its nutritional properties. This is relevant to understand the thermal load calculation in order to be able to dimension the refrigeration equipment used for the industrial refrigeration cycle. The objectives of the article were to calculate the thermal load of an industrialized açaí freezing tunnel with a capacity of 20 tons in 18 hours of process and to verify the factor of greatest influence in this calculation. This is field research carried out in an açaí freezing industry in the city of Castanhal / PA and also refers to an exploratory bibliographic research based on books and scientific articles in the industrial refrigeration category. The total thermal load of the açaí freezing tunnel was calculated and reached the value of 168,347.0226 kcal/h and it was found that the factor of greatest influence in the calculation of thermal load is the factor for the product with about 81% of the total thermal load.
id UFV-4_09aaf5102986c78e9ac5fb33d9f6c15f
oai_identifier_str oai:ojs.periodicos.ufv.br:article/14190
network_acronym_str UFV-4
network_name_str Revista de Engenharia Química e Química
repository_id_str
spelling Thermal load calculation of an industrialized açaí freezing tunnel with a capacity of 20 tonsCálculo de carga térmica de um túnel de congelamento de açaí industrializado com capacidade de 20 toneladasAçaíThermal LoadIndustrial RefrigerationFreezing TunnelAçaíCarga TérmicaRefrigeração IndustrialTúnel de CongelamentoAçaí is a fruit native to the Amazon region that is important as a source of food and for a local culture and that has become popular nationally in the most recent decades, already reaching international markets. The freezing process is used to delay the deterioration of food, preserving its nutritional properties. This is relevant to understand the thermal load calculation in order to be able to dimension the refrigeration equipment used for the industrial refrigeration cycle. The objectives of the article were to calculate the thermal load of an industrialized açaí freezing tunnel with a capacity of 20 tons in 18 hours of process and to verify the factor of greatest influence in this calculation. This is field research carried out in an açaí freezing industry in the city of Castanhal / PA and also refers to an exploratory bibliographic research based on books and scientific articles in the industrial refrigeration category. The total thermal load of the açaí freezing tunnel was calculated and reached the value of 168,347.0226 kcal/h and it was found that the factor of greatest influence in the calculation of thermal load is the factor for the product with about 81% of the total thermal load.O açaí é um fruto nativo da região amazônica que é importante como fonte de alimento e para a cultura local e que se popularizou nacionalmente nas mais recentes décadas, já atingindo mercados internacionais. É utilizado o processo de congelamento para postergar a deterioração dos alimentos em geral, conservando às suas propriedades nutritivas. É relevante se compreender o cálculo de carga térmica para ser possível dimensionar adequadamente os equipamentos frigoríficos necessários para o ciclo de refrigeração industrial. Os objetivos do trabalho foram os de calcular a carga térmica de um túnel de congelamento de açaí industrializado com capacidade de 20 toneladas em 18 h de processo e verificar o fator de maior influência neste respectivo cálculo. Trata-se de uma pesquisa de campo realizada em uma indústria de congelamento de açaí na cidade de Castanhal/PA e se refere à uma pesquisa bibliográfica exploratória baseada em livros e trabalhos científicos da categoria de refrigeração industrial. Calculou-se a carga térmica total do túnel de congelamento de açaí e se chegou no valor de 168.347,0226 kcal/h e verificou-se que o fator de maior influência no cálculo de carga térmica é o fator pelo produto com cerca de 81% da carga térmica total.Universidade Federal de Viçosa - UFV2022-04-27info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtigo, Manuscrito, Eventosapplication/pdfhttps://periodicos.ufv.br/jcec/article/view/1419010.18540/jcecvl8iss4pp14190-01eThe Journal of Engineering and Exact Sciences; Vol. 8 No. 4 (2022); 14190-01eThe Journal of Engineering and Exact Sciences; Vol. 8 Núm. 4 (2022); 14190-01eThe Journal of Engineering and Exact Sciences; v. 8 n. 4 (2022); 14190-01e2527-1075reponame:Revista de Engenharia Química e Químicainstname:Universidade Federal de Viçosa (UFV)instacron:UFVporhttps://periodicos.ufv.br/jcec/article/view/14190/7298Copyright (c) 2022 The Journal of Engineering and Exact Scienceshttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessPereira, Marcos DuranSiqueira, Antonio Marcos de Oliveira2022-07-28T18:11:17Zoai:ojs.periodicos.ufv.br:article/14190Revistahttp://www.seer.ufv.br/seer/rbeq2/index.php/req2/indexONGhttps://periodicos.ufv.br/jcec/oaijcec.journal@ufv.br||req2@ufv.br2446-94162446-9416opendoar:2022-07-28T18:11:17Revista de Engenharia Química e Química - Universidade Federal de Viçosa (UFV)false
dc.title.none.fl_str_mv Thermal load calculation of an industrialized açaí freezing tunnel with a capacity of 20 tons
Cálculo de carga térmica de um túnel de congelamento de açaí industrializado com capacidade de 20 toneladas
title Thermal load calculation of an industrialized açaí freezing tunnel with a capacity of 20 tons
spellingShingle Thermal load calculation of an industrialized açaí freezing tunnel with a capacity of 20 tons
Pereira, Marcos Duran
Açaí
Thermal Load
Industrial Refrigeration
Freezing Tunnel
Açaí
Carga Térmica
Refrigeração Industrial
Túnel de Congelamento
title_short Thermal load calculation of an industrialized açaí freezing tunnel with a capacity of 20 tons
title_full Thermal load calculation of an industrialized açaí freezing tunnel with a capacity of 20 tons
title_fullStr Thermal load calculation of an industrialized açaí freezing tunnel with a capacity of 20 tons
title_full_unstemmed Thermal load calculation of an industrialized açaí freezing tunnel with a capacity of 20 tons
title_sort Thermal load calculation of an industrialized açaí freezing tunnel with a capacity of 20 tons
author Pereira, Marcos Duran
author_facet Pereira, Marcos Duran
Siqueira, Antonio Marcos de Oliveira
author_role author
author2 Siqueira, Antonio Marcos de Oliveira
author2_role author
dc.contributor.author.fl_str_mv Pereira, Marcos Duran
Siqueira, Antonio Marcos de Oliveira
dc.subject.por.fl_str_mv Açaí
Thermal Load
Industrial Refrigeration
Freezing Tunnel
Açaí
Carga Térmica
Refrigeração Industrial
Túnel de Congelamento
topic Açaí
Thermal Load
Industrial Refrigeration
Freezing Tunnel
Açaí
Carga Térmica
Refrigeração Industrial
Túnel de Congelamento
description Açaí is a fruit native to the Amazon region that is important as a source of food and for a local culture and that has become popular nationally in the most recent decades, already reaching international markets. The freezing process is used to delay the deterioration of food, preserving its nutritional properties. This is relevant to understand the thermal load calculation in order to be able to dimension the refrigeration equipment used for the industrial refrigeration cycle. The objectives of the article were to calculate the thermal load of an industrialized açaí freezing tunnel with a capacity of 20 tons in 18 hours of process and to verify the factor of greatest influence in this calculation. This is field research carried out in an açaí freezing industry in the city of Castanhal / PA and also refers to an exploratory bibliographic research based on books and scientific articles in the industrial refrigeration category. The total thermal load of the açaí freezing tunnel was calculated and reached the value of 168,347.0226 kcal/h and it was found that the factor of greatest influence in the calculation of thermal load is the factor for the product with about 81% of the total thermal load.
publishDate 2022
dc.date.none.fl_str_mv 2022-04-27
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Artigo, Manuscrito, Eventos
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.ufv.br/jcec/article/view/14190
10.18540/jcecvl8iss4pp14190-01e
url https://periodicos.ufv.br/jcec/article/view/14190
identifier_str_mv 10.18540/jcecvl8iss4pp14190-01e
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://periodicos.ufv.br/jcec/article/view/14190/7298
dc.rights.driver.fl_str_mv Copyright (c) 2022 The Journal of Engineering and Exact Sciences
https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2022 The Journal of Engineering and Exact Sciences
https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Viçosa - UFV
publisher.none.fl_str_mv Universidade Federal de Viçosa - UFV
dc.source.none.fl_str_mv The Journal of Engineering and Exact Sciences; Vol. 8 No. 4 (2022); 14190-01e
The Journal of Engineering and Exact Sciences; Vol. 8 Núm. 4 (2022); 14190-01e
The Journal of Engineering and Exact Sciences; v. 8 n. 4 (2022); 14190-01e
2527-1075
reponame:Revista de Engenharia Química e Química
instname:Universidade Federal de Viçosa (UFV)
instacron:UFV
instname_str Universidade Federal de Viçosa (UFV)
instacron_str UFV
institution UFV
reponame_str Revista de Engenharia Química e Química
collection Revista de Engenharia Química e Química
repository.name.fl_str_mv Revista de Engenharia Química e Química - Universidade Federal de Viçosa (UFV)
repository.mail.fl_str_mv jcec.journal@ufv.br||req2@ufv.br
_version_ 1800211190604890112