Vestibular evoked myogenic potentials: an overview
Autor(a) principal: | |
---|---|
Data de Publicação: | 2009 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UnB |
Texto Completo: | http://repositorio.unb.br/handle/10482/27577 https://dx.doi.org/10.1590/S1808-86942009000300023 |
Resumo: | The vestibular evoked myogenic potential (VEMP) test is a relatively new diagnostic tool that is in the process of being investigated in patients with specific vestibular disorders. Briefly, the VEMP is a biphasic response elicited by loud clicks or tone bursts recorded from the tonically contracted sternocleidomastoid muscle, being the only resource available to assess the function of the saccule and the lower portion of the vestibular nerve. AIM: In this review, we shall highlight the history, methods, current VEMP status, and discuss its specific application in the diagnosis of the Ménière's Syndrome. |
id |
UNB_4dd93c6b10b38cf979a09cd1c90dad24 |
---|---|
oai_identifier_str |
oai:repositorio.unb.br:10482/27577 |
network_acronym_str |
UNB |
network_name_str |
Repositório Institucional da UnB |
repository_id_str |
|
spelling |
Vestibular evoked myogenic potentials: an overviewPotencial evocado miogênico vestibular: uma visão geralVestibularHidropsia endolinfáticaPotenciais evocadosThe vestibular evoked myogenic potential (VEMP) test is a relatively new diagnostic tool that is in the process of being investigated in patients with specific vestibular disorders. Briefly, the VEMP is a biphasic response elicited by loud clicks or tone bursts recorded from the tonically contracted sternocleidomastoid muscle, being the only resource available to assess the function of the saccule and the lower portion of the vestibular nerve. AIM: In this review, we shall highlight the history, methods, current VEMP status, and discuss its specific application in the diagnosis of the Ménière's Syndrome.O teste do potencial evocado miogênico vestibular (PEMV) é um instrumento diagnóstico relativamente novo e ainda em processo de validação em estudos com pacientes portadores de desordens vestibulares específicas. De forma resumida, o PEMV é uma resposta bifásica em resposta a estímulos sonoros gravados a partir de contrações do músculo esternocleidomastóideo e é o único recurso existente para avaliar a função do sáculo e da divisão inferior do nervo vestibular. OBJETIVO: Nesta revisão iremos destacar a história, método de realização, situação atual da pesquisa envolvendo o PEMV, além de discutir as suas aplicações específicas no diagnóstico da síndrome de Ménière.Em processamentoAssociação Brasileira de Otorrinolaringologia e Cirurgia Cervicofacial2017-12-07T04:52:19Z2017-12-07T04:52:19Z2009info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfBraz. j. otorhinolaryngol. (Impr.),v.75,n.3,p.456-462,2009http://repositorio.unb.br/handle/10482/27577https://dx.doi.org/10.1590/S1808-86942009000300023Cal, RenatoBahmad Jr, Fayezinfo:eu-repo/semantics/openAccessengreponame:Repositório Institucional da UnBinstname:Universidade de Brasília (UnB)instacron:UNB2024-08-28T16:32:49Zoai:repositorio.unb.br:10482/27577Repositório InstitucionalPUBhttps://repositorio.unb.br/oai/requestrepositorio@unb.bropendoar:2024-08-28T16:32:49Repositório Institucional da UnB - Universidade de Brasília (UnB)false |
dc.title.none.fl_str_mv |
Vestibular evoked myogenic potentials: an overview Potencial evocado miogênico vestibular: uma visão geral |
title |
Vestibular evoked myogenic potentials: an overview |
spellingShingle |
Vestibular evoked myogenic potentials: an overview Cal, Renato Vestibular Hidropsia endolinfática Potenciais evocados |
title_short |
Vestibular evoked myogenic potentials: an overview |
title_full |
Vestibular evoked myogenic potentials: an overview |
title_fullStr |
Vestibular evoked myogenic potentials: an overview |
title_full_unstemmed |
Vestibular evoked myogenic potentials: an overview |
title_sort |
Vestibular evoked myogenic potentials: an overview |
author |
Cal, Renato |
author_facet |
Cal, Renato Bahmad Jr, Fayez |
author_role |
author |
author2 |
Bahmad Jr, Fayez |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Cal, Renato Bahmad Jr, Fayez |
dc.subject.por.fl_str_mv |
Vestibular Hidropsia endolinfática Potenciais evocados |
topic |
Vestibular Hidropsia endolinfática Potenciais evocados |
description |
The vestibular evoked myogenic potential (VEMP) test is a relatively new diagnostic tool that is in the process of being investigated in patients with specific vestibular disorders. Briefly, the VEMP is a biphasic response elicited by loud clicks or tone bursts recorded from the tonically contracted sternocleidomastoid muscle, being the only resource available to assess the function of the saccule and the lower portion of the vestibular nerve. AIM: In this review, we shall highlight the history, methods, current VEMP status, and discuss its specific application in the diagnosis of the Ménière's Syndrome. |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009 2017-12-07T04:52:19Z 2017-12-07T04:52:19Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
Braz. j. otorhinolaryngol. (Impr.),v.75,n.3,p.456-462,2009 http://repositorio.unb.br/handle/10482/27577 https://dx.doi.org/10.1590/S1808-86942009000300023 |
identifier_str_mv |
Braz. j. otorhinolaryngol. (Impr.),v.75,n.3,p.456-462,2009 |
url |
http://repositorio.unb.br/handle/10482/27577 https://dx.doi.org/10.1590/S1808-86942009000300023 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Associação Brasileira de Otorrinolaringologia e Cirurgia Cervicofacial |
publisher.none.fl_str_mv |
Associação Brasileira de Otorrinolaringologia e Cirurgia Cervicofacial |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UnB instname:Universidade de Brasília (UnB) instacron:UNB |
instname_str |
Universidade de Brasília (UnB) |
instacron_str |
UNB |
institution |
UNB |
reponame_str |
Repositório Institucional da UnB |
collection |
Repositório Institucional da UnB |
repository.name.fl_str_mv |
Repositório Institucional da UnB - Universidade de Brasília (UnB) |
repository.mail.fl_str_mv |
repositorio@unb.br |
_version_ |
1814508277237547008 |