Avaliação da confiabilidade de bombas de infusão hospitalares

Detalhes bibliográficos
Autor(a) principal: Silva, Mayla dos Santos
Data de Publicação: 2024
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UnB
Texto Completo: http://repositorio2.unb.br/jspui/handle/10482/48997
Resumo: Tese (doutorado) — Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, Programa de Pós-Graduação em Sistemas Mecatrônicos, 2023.
id UNB_511dad0d49f577c97b4c58eb9f4d5838
oai_identifier_str oai:repositorio.unb.br:10482/48997
network_acronym_str UNB
network_name_str Repositório Institucional da UnB
repository_id_str
spelling Avaliação da confiabilidade de bombas de infusão hospitalaresDispositivo médicoBomba de infusãoSistemas mecatrônicosTese (doutorado) — Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, Programa de Pós-Graduação em Sistemas Mecatrônicos, 2023.Bombas de Infusão (BI) são dispositivos médicos (DM) utilizados para administração de medicamentos ou alimentos de forma contínua e precisa. Ao passar dos anos sua utilização se expandiu, sendo atualmente empregado nas emergências, UTIs, pediatria e vários outros setores hospitalares. Na pandemia de COVID-19 vivenciada recentemente, houve intensificação no uso desse dispositivo em razão da demanda de administração de altas doses de sedativos para pacientes em ventilação. Assim como os demais equipamentos invasivos, as manutenções são exigidas com maior atenção e periodicidade, a fim de manter o bom funcionamento e precisão na infusão. Caso as BI falhem, são capazes ocasionar eventos adversos que podem gerar danos ao paciente, prejudicando seu quadro de saúde. Além dos problemas associados ao paciente, a BI ´e o DM que possui maior número de notificações de eventos adversos no Brasil, o que eleva a necessidade de verificação de condições que o dispositivo está operando, visando minimizar falhas durante o uso. Diante deste panorama, o objetivo da presente pesquisa ´e analisar a confiabilidade de BI operantes em um hospital brasileiro, utilizando o banco de dados interno, construído a partir do software de Engenharia Clínica. Foram modeladas as distribuições de probabilidade para tempo de reparo e tempo entre falhas, calculados aspectos como confiabilidade e disponibilidade de BI hospitalares por meio da análise de falhas, em concordância com as recomendações nacionais/internacionais, e investigados os setores hospitalares com falhas recorrentes e serviços executados. Ademais, propomos realizar uma revisão sistemática de literatura para certificar como estudos sobre a confiabilidade das bombas e outros parâmetros metrológicos vem sendo estudados nos últimos anos, para finalmente propor um planeja mento para verificação das bombas. A revisão demonstrou que o método gravimétrico ´e uma proposta que traz resultados positivos na avaliação do fluxo, sendo uma alternativa para os responsáveis da engenharia clínica. Ficou evidente que há carência de estudos que abordem conceitos de confiabilidade aplicada `a BI, destacando os que envolvam ensaios de bancada e in loco. Na avaliação dos equipamentos operantes, observou-se ausência de detalhes em anotações para o motivo da falha e na abertura da ordem de serviço, os quais podem gerar imprecisão no planejamento das manutenções. O maior tempo de reparo foi identificado na Unidade de Terapia Intensiva (Neurológica), setor que compreende a maioria das bombas. As análises gráficas e testes apontaram que a distribuição de Weibull modela satisfatoriamente tanto o tempo entre falhas quanto o tempo de reparo das máquinas, e o modelo A demonstrou melhores resultados quanto à disponibilidade e confiabilidade. Por fim, o estudo propõe um planejamento que une recomendações nacionais com ciclo de confiabilidade para DM visando a verificação das BI, a fim de que possa ser englobado na rotina de manutenções preditivas e preventivas.Infusion Pumps (IP) are medical devices (MD) used to administer medicines or food continuously and precisely. Over the years, its use has expanded, currently being used in emergencies, ICUs, pediatrics and several other hospital sectors. In the recent COVID-19 pandemic, there was an intensification in the use of this device due to the demand for administering high doses of sedatives to patients on ventilation. As with other invasive equipment, maintenance is required with greater attention and frequency, in order to maintain good functioning and precision in the infusion. If the IPs fail, they can cause adverse events that can cause harm to the patient, harming their health. In addition to the problems associated with the patient, IP is the DM that has the highest number of adverse event reports in Brazil, which increases the need to verify the conditions under which the device is operating, aiming to minimize failures during use. Given this panorama, the objective of this research is to analyze the reliability of IP operating in a Brazilian hospital, using an internal database, built from Clinical En gineering software. Probability distributions for repair time and time between failures were modeled, aspects such as reliability and availability of hospital IPs were calcula ted through failure analysis, in accordance with national/international recommendations, and hospital sectors with recurrent failures were investigated. and services performed. Furthermore, we propose to carry out a systematic literature review to certify how studies on the reliability of pumps and other metrological parameters have been studied in recent years, to finally propose a plan for checking the pumps. The review demonstrated that the gravimetric method is a proposal that brings po sitive results in flow assessment, being an alternative for those responsible for clinical engineering. It was evident that there is a lack of studies that address reliability concepts applied to IP, highlighting those involving bench and on-site tests. In the evaluation of the operating equipment, it was observed that there were no details in the notes regar ding the reason for the failure and when opening the work order, which could lead to inaccuracy in maintenance planning. The longest repair time was identified in the Inten sive Care Unit (Neurological), a sector that comprises the majority of pumps. Graphical analyzes and tests showed that the Weibull distribution satisfactorily models both the time between failures and the time to repair machines, and model A demonstrated better results in terms of availability and reliability. Finally, the study proposes a plan that combines national recommendations with a reliability cycle for DM aimed at verifying BI, so that it can be included in the predictive and preventive maintenance routine.Faculdade de Tecnologia (FT)Departamento de Engenharia Mecânica (FT ENM)Programa de Pós-Graduação em Sistemas MecatrônicosPiratelli Filho, AntônioRosa, Suélia de Siqueira Rodrigues Fleurymayla.s@hotmail.comSilva, Mayla dos Santos2024-07-17T23:13:20Z2024-07-17T23:13:20Z2024-07-172024-03-15info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdfSILVA, Mayla dos Santos. Avaliação da confiabilidade de bombas de infusão hospitalares. 2023. 120 f., il. Tese (Doutorado em Sistemas Mecatrônicos) — Universidade de Brasília, Brasília, 2023.http://repositorio2.unb.br/jspui/handle/10482/48997porinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UnBinstname:Universidade de Brasília (UnB)instacron:UNB2024-07-17T23:13:20Zoai:repositorio.unb.br:10482/48997Repositório InstitucionalPUBhttps://repositorio.unb.br/oai/requestrepositorio@unb.bropendoar:2024-07-17T23:13:20Repositório Institucional da UnB - Universidade de Brasília (UnB)false
dc.title.none.fl_str_mv Avaliação da confiabilidade de bombas de infusão hospitalares
title Avaliação da confiabilidade de bombas de infusão hospitalares
spellingShingle Avaliação da confiabilidade de bombas de infusão hospitalares
Silva, Mayla dos Santos
Dispositivo médico
Bomba de infusão
Sistemas mecatrônicos
title_short Avaliação da confiabilidade de bombas de infusão hospitalares
title_full Avaliação da confiabilidade de bombas de infusão hospitalares
title_fullStr Avaliação da confiabilidade de bombas de infusão hospitalares
title_full_unstemmed Avaliação da confiabilidade de bombas de infusão hospitalares
title_sort Avaliação da confiabilidade de bombas de infusão hospitalares
author Silva, Mayla dos Santos
author_facet Silva, Mayla dos Santos
author_role author
dc.contributor.none.fl_str_mv Piratelli Filho, Antônio
Rosa, Suélia de Siqueira Rodrigues Fleury
mayla.s@hotmail.com
dc.contributor.author.fl_str_mv Silva, Mayla dos Santos
dc.subject.por.fl_str_mv Dispositivo médico
Bomba de infusão
Sistemas mecatrônicos
topic Dispositivo médico
Bomba de infusão
Sistemas mecatrônicos
description Tese (doutorado) — Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, Programa de Pós-Graduação em Sistemas Mecatrônicos, 2023.
publishDate 2024
dc.date.none.fl_str_mv 2024-07-17T23:13:20Z
2024-07-17T23:13:20Z
2024-07-17
2024-03-15
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv SILVA, Mayla dos Santos. Avaliação da confiabilidade de bombas de infusão hospitalares. 2023. 120 f., il. Tese (Doutorado em Sistemas Mecatrônicos) — Universidade de Brasília, Brasília, 2023.
http://repositorio2.unb.br/jspui/handle/10482/48997
identifier_str_mv SILVA, Mayla dos Santos. Avaliação da confiabilidade de bombas de infusão hospitalares. 2023. 120 f., il. Tese (Doutorado em Sistemas Mecatrônicos) — Universidade de Brasília, Brasília, 2023.
url http://repositorio2.unb.br/jspui/handle/10482/48997
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UnB
instname:Universidade de Brasília (UnB)
instacron:UNB
instname_str Universidade de Brasília (UnB)
instacron_str UNB
institution UNB
reponame_str Repositório Institucional da UnB
collection Repositório Institucional da UnB
repository.name.fl_str_mv Repositório Institucional da UnB - Universidade de Brasília (UnB)
repository.mail.fl_str_mv repositorio@unb.br
_version_ 1814508328882012160