Relining effects on the push-out shear bond strength of glass fiber posts

Detalhes bibliográficos
Autor(a) principal: ANDRIOLI,Adriana Rosado Valente
Data de Publicação: 2016
Outros Autores: COUTINHO,Margareth, VASCONCELLOS,Andréa Araújo de, MIRANDA,Milton Edson
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista de Odontologia da UNESP
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016000400227
Resumo: Abstract Introduction The correct use of glass fiber posts in endodontically treated teeth is essential for the clinical success of restorative treatment. Objective This study evaluated the push-out shear bond strength of relined (R) or non-relined (NR) glass fiber posts, cemented with self-adhesive resin cement [RelyXTM U100 (U100)] and conventional resin cement [RelyXTM ARC (ARC)]. Material and method Sixty human single-rooted teeth were endodontically treated and divided into ARC-NR; U100-NR; ARC-R; U100-R groups. The teeth were sectioned into cervical, middle and apical thirds, and subjected to the push-out test. Bond strength was analyzed by the Friedman test; cement and post types were compared by the Mann Whitney test. The pattern of failures was evaluated with digital camera through images at 200x magnification, and was classified as adhesive (at the cement/dentin or cement/post interface), cohesive (cement or post), and mixed failures. Result In ARC-NR, bond strength values were higher in the cervical third; in U100-NR and ARC-R they were similar between the thirds. In U100-R, in the cervical and middle thirds the bond strength values were similar, and there was lower value in the apical third. For non-relined glass fiber posts, the highest mean bond strength values were observed with self-adhesive resin cement. Whereas, relined posts cemented with conventional resin cement had stronger cement layer in comparison with non-relined fiber posts. Conclusion The post relining technique was efficient in ARC-R. ARC-NR and U100-R showed improved bond strength in the cervical region of canal walls. The main failures were adhesive at the cement-post interface.
id UNESP-16_602176302ab258a6b0d1eeba1e974c7b
oai_identifier_str oai:scielo:S1807-25772016000400227
network_acronym_str UNESP-16
network_name_str Revista de Odontologia da UNESP
repository_id_str
spelling Relining effects on the push-out shear bond strength of glass fiber postsDental bondingdental materialsdentinpost and core techniqueshear strengthAbstract Introduction The correct use of glass fiber posts in endodontically treated teeth is essential for the clinical success of restorative treatment. Objective This study evaluated the push-out shear bond strength of relined (R) or non-relined (NR) glass fiber posts, cemented with self-adhesive resin cement [RelyXTM U100 (U100)] and conventional resin cement [RelyXTM ARC (ARC)]. Material and method Sixty human single-rooted teeth were endodontically treated and divided into ARC-NR; U100-NR; ARC-R; U100-R groups. The teeth were sectioned into cervical, middle and apical thirds, and subjected to the push-out test. Bond strength was analyzed by the Friedman test; cement and post types were compared by the Mann Whitney test. The pattern of failures was evaluated with digital camera through images at 200x magnification, and was classified as adhesive (at the cement/dentin or cement/post interface), cohesive (cement or post), and mixed failures. Result In ARC-NR, bond strength values were higher in the cervical third; in U100-NR and ARC-R they were similar between the thirds. In U100-R, in the cervical and middle thirds the bond strength values were similar, and there was lower value in the apical third. For non-relined glass fiber posts, the highest mean bond strength values were observed with self-adhesive resin cement. Whereas, relined posts cemented with conventional resin cement had stronger cement layer in comparison with non-relined fiber posts. Conclusion The post relining technique was efficient in ARC-R. ARC-NR and U100-R showed improved bond strength in the cervical region of canal walls. The main failures were adhesive at the cement-post interface.Universidade Estadual Paulista Júlio de Mesquita Filho2016-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016000400227Revista de Odontologia da UNESP v.45 n.4 2016reponame:Revista de Odontologia da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESP10.1590/1807-2577.14815info:eu-repo/semantics/openAccessANDRIOLI,Adriana Rosado ValenteCOUTINHO,MargarethVASCONCELLOS,Andréa Araújo deMIRANDA,Milton Edsoneng2016-09-09T00:00:00Zoai:scielo:S1807-25772016000400227Revistahttps://www.revodontolunesp.com.br/PUBhttps://old.scielo.br/oai/scielo-oai.php||adriana@foar.unesp.br1807-25770101-1774opendoar:2016-09-09T00:00Revista de Odontologia da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Relining effects on the push-out shear bond strength of glass fiber posts
title Relining effects on the push-out shear bond strength of glass fiber posts
spellingShingle Relining effects on the push-out shear bond strength of glass fiber posts
ANDRIOLI,Adriana Rosado Valente
Dental bonding
dental materials
dentin
post and core technique
shear strength
title_short Relining effects on the push-out shear bond strength of glass fiber posts
title_full Relining effects on the push-out shear bond strength of glass fiber posts
title_fullStr Relining effects on the push-out shear bond strength of glass fiber posts
title_full_unstemmed Relining effects on the push-out shear bond strength of glass fiber posts
title_sort Relining effects on the push-out shear bond strength of glass fiber posts
author ANDRIOLI,Adriana Rosado Valente
author_facet ANDRIOLI,Adriana Rosado Valente
COUTINHO,Margareth
VASCONCELLOS,Andréa Araújo de
MIRANDA,Milton Edson
author_role author
author2 COUTINHO,Margareth
VASCONCELLOS,Andréa Araújo de
MIRANDA,Milton Edson
author2_role author
author
author
dc.contributor.author.fl_str_mv ANDRIOLI,Adriana Rosado Valente
COUTINHO,Margareth
VASCONCELLOS,Andréa Araújo de
MIRANDA,Milton Edson
dc.subject.por.fl_str_mv Dental bonding
dental materials
dentin
post and core technique
shear strength
topic Dental bonding
dental materials
dentin
post and core technique
shear strength
description Abstract Introduction The correct use of glass fiber posts in endodontically treated teeth is essential for the clinical success of restorative treatment. Objective This study evaluated the push-out shear bond strength of relined (R) or non-relined (NR) glass fiber posts, cemented with self-adhesive resin cement [RelyXTM U100 (U100)] and conventional resin cement [RelyXTM ARC (ARC)]. Material and method Sixty human single-rooted teeth were endodontically treated and divided into ARC-NR; U100-NR; ARC-R; U100-R groups. The teeth were sectioned into cervical, middle and apical thirds, and subjected to the push-out test. Bond strength was analyzed by the Friedman test; cement and post types were compared by the Mann Whitney test. The pattern of failures was evaluated with digital camera through images at 200x magnification, and was classified as adhesive (at the cement/dentin or cement/post interface), cohesive (cement or post), and mixed failures. Result In ARC-NR, bond strength values were higher in the cervical third; in U100-NR and ARC-R they were similar between the thirds. In U100-R, in the cervical and middle thirds the bond strength values were similar, and there was lower value in the apical third. For non-relined glass fiber posts, the highest mean bond strength values were observed with self-adhesive resin cement. Whereas, relined posts cemented with conventional resin cement had stronger cement layer in comparison with non-relined fiber posts. Conclusion The post relining technique was efficient in ARC-R. ARC-NR and U100-R showed improved bond strength in the cervical region of canal walls. The main failures were adhesive at the cement-post interface.
publishDate 2016
dc.date.none.fl_str_mv 2016-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016000400227
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016000400227
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1807-2577.14815
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Universidade Estadual Paulista Júlio de Mesquita Filho
publisher.none.fl_str_mv Universidade Estadual Paulista Júlio de Mesquita Filho
dc.source.none.fl_str_mv Revista de Odontologia da UNESP v.45 n.4 2016
reponame:Revista de Odontologia da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Revista de Odontologia da UNESP
collection Revista de Odontologia da UNESP
repository.name.fl_str_mv Revista de Odontologia da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv ||adriana@foar.unesp.br
_version_ 1748958559831326720