Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista de Odontologia da UNESP |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016000500271 |
Resumo: | Abstract Background The study of the phenomenon of fatigue is essential because implant failures usually are caused by this process. Purpose The objective of this study was to examine the fatigue resistance of straight and anatomical abutments joints that were submitted to cyclic loads. Material and method We used 37 Morse taper implants and 37 abutments, divided into two groups (n= 16: straight abutment, n= 21 anatomical abutment). The sets were submitted to cyclic loading (5 million) using servo-hydraulic equipment. Three sets from each group were subjected to bending tests to determine the maximum load resistance, which served as the parameter for comparison of the cyclic tests. We evaluated number of cycles, load and bending moment. Result Of the 31 abutments cyclically tested, 17 (54.8%) fractured in fewer than 5 million cycles; 8 (25.8%) of these were straight abutments, and 9 (29%) were anatomical. A total of 14 samples (45.2%) resisted the cyclic loading. According to Fisher's exact test, there was no difference between groups as the fracture. Conclusion Despite of the straight abutments have higher average load and bending moment on the anatomical, both types of abutments showed similar performance as the fracture strength in vitro. |
id |
UNESP-16_7455cd63499496e395d81fc15ecc85b1 |
---|---|
oai_identifier_str |
oai:scielo:S1807-25772016000500271 |
network_acronym_str |
UNESP-16 |
network_name_str |
Revista de Odontologia da UNESP |
repository_id_str |
|
spelling |
Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper systemDental implantsmaterial resistancemechanical phenomenaAbstract Background The study of the phenomenon of fatigue is essential because implant failures usually are caused by this process. Purpose The objective of this study was to examine the fatigue resistance of straight and anatomical abutments joints that were submitted to cyclic loads. Material and method We used 37 Morse taper implants and 37 abutments, divided into two groups (n= 16: straight abutment, n= 21 anatomical abutment). The sets were submitted to cyclic loading (5 million) using servo-hydraulic equipment. Three sets from each group were subjected to bending tests to determine the maximum load resistance, which served as the parameter for comparison of the cyclic tests. We evaluated number of cycles, load and bending moment. Result Of the 31 abutments cyclically tested, 17 (54.8%) fractured in fewer than 5 million cycles; 8 (25.8%) of these were straight abutments, and 9 (29%) were anatomical. A total of 14 samples (45.2%) resisted the cyclic loading. According to Fisher's exact test, there was no difference between groups as the fracture. Conclusion Despite of the straight abutments have higher average load and bending moment on the anatomical, both types of abutments showed similar performance as the fracture strength in vitro.Universidade Estadual Paulista Júlio de Mesquita Filho2016-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016000500271Revista de Odontologia da UNESP v.45 n.5 2016reponame:Revista de Odontologia da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESP10.1590/1807-2577.08216info:eu-repo/semantics/openAccessGOIS-SANTOS,Vanessa Tavares deTRENTO,Cleverson LucianoSANTOS,Silvando Vieira dosSANTOS,Renan Celestino SilvaSANTOS,Victor SantanaGRIZA,Sandroeng2016-10-28T00:00:00Zoai:scielo:S1807-25772016000500271Revistahttps://www.revodontolunesp.com.br/PUBhttps://old.scielo.br/oai/scielo-oai.php||adriana@foar.unesp.br1807-25770101-1774opendoar:2016-10-28T00:00Revista de Odontologia da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system |
title |
Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system |
spellingShingle |
Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system GOIS-SANTOS,Vanessa Tavares de Dental implants material resistance mechanical phenomena |
title_short |
Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system |
title_full |
Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system |
title_fullStr |
Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system |
title_full_unstemmed |
Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system |
title_sort |
Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system |
author |
GOIS-SANTOS,Vanessa Tavares de |
author_facet |
GOIS-SANTOS,Vanessa Tavares de TRENTO,Cleverson Luciano SANTOS,Silvando Vieira dos SANTOS,Renan Celestino Silva SANTOS,Victor Santana GRIZA,Sandro |
author_role |
author |
author2 |
TRENTO,Cleverson Luciano SANTOS,Silvando Vieira dos SANTOS,Renan Celestino Silva SANTOS,Victor Santana GRIZA,Sandro |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
GOIS-SANTOS,Vanessa Tavares de TRENTO,Cleverson Luciano SANTOS,Silvando Vieira dos SANTOS,Renan Celestino Silva SANTOS,Victor Santana GRIZA,Sandro |
dc.subject.por.fl_str_mv |
Dental implants material resistance mechanical phenomena |
topic |
Dental implants material resistance mechanical phenomena |
description |
Abstract Background The study of the phenomenon of fatigue is essential because implant failures usually are caused by this process. Purpose The objective of this study was to examine the fatigue resistance of straight and anatomical abutments joints that were submitted to cyclic loads. Material and method We used 37 Morse taper implants and 37 abutments, divided into two groups (n= 16: straight abutment, n= 21 anatomical abutment). The sets were submitted to cyclic loading (5 million) using servo-hydraulic equipment. Three sets from each group were subjected to bending tests to determine the maximum load resistance, which served as the parameter for comparison of the cyclic tests. We evaluated number of cycles, load and bending moment. Result Of the 31 abutments cyclically tested, 17 (54.8%) fractured in fewer than 5 million cycles; 8 (25.8%) of these were straight abutments, and 9 (29%) were anatomical. A total of 14 samples (45.2%) resisted the cyclic loading. According to Fisher's exact test, there was no difference between groups as the fracture. Conclusion Despite of the straight abutments have higher average load and bending moment on the anatomical, both types of abutments showed similar performance as the fracture strength in vitro. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016000500271 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016000500271 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1807-2577.08216 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Universidade Estadual Paulista Júlio de Mesquita Filho |
publisher.none.fl_str_mv |
Universidade Estadual Paulista Júlio de Mesquita Filho |
dc.source.none.fl_str_mv |
Revista de Odontologia da UNESP v.45 n.5 2016 reponame:Revista de Odontologia da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Revista de Odontologia da UNESP |
collection |
Revista de Odontologia da UNESP |
repository.name.fl_str_mv |
Revista de Odontologia da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
||adriana@foar.unesp.br |
_version_ |
1748958559842861056 |