Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system

Detalhes bibliográficos
Autor(a) principal: GOIS-SANTOS,Vanessa Tavares de
Data de Publicação: 2016
Outros Autores: TRENTO,Cleverson Luciano, SANTOS,Silvando Vieira dos, SANTOS,Renan Celestino Silva, SANTOS,Victor Santana, GRIZA,Sandro
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista de Odontologia da UNESP
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016000500271
Resumo: Abstract Background The study of the phenomenon of fatigue is essential because implant failures usually are caused by this process. Purpose The objective of this study was to examine the fatigue resistance of straight and anatomical abutments joints that were submitted to cyclic loads. Material and method We used 37 Morse taper implants and 37 abutments, divided into two groups (n= 16: straight abutment, n= 21 anatomical abutment). The sets were submitted to cyclic loading (5 million) using servo-hydraulic equipment. Three sets from each group were subjected to bending tests to determine the maximum load resistance, which served as the parameter for comparison of the cyclic tests. We evaluated number of cycles, load and bending moment. Result Of the 31 abutments cyclically tested, 17 (54.8%) fractured in fewer than 5 million cycles; 8 (25.8%) of these were straight abutments, and 9 (29%) were anatomical. A total of 14 samples (45.2%) resisted the cyclic loading. According to Fisher's exact test, there was no difference between groups as the fracture. Conclusion Despite of the straight abutments have higher average load and bending moment on the anatomical, both types of abutments showed similar performance as the fracture strength in vitro.
id UNESP-16_7455cd63499496e395d81fc15ecc85b1
oai_identifier_str oai:scielo:S1807-25772016000500271
network_acronym_str UNESP-16
network_name_str Revista de Odontologia da UNESP
repository_id_str
spelling Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper systemDental implantsmaterial resistancemechanical phenomenaAbstract Background The study of the phenomenon of fatigue is essential because implant failures usually are caused by this process. Purpose The objective of this study was to examine the fatigue resistance of straight and anatomical abutments joints that were submitted to cyclic loads. Material and method We used 37 Morse taper implants and 37 abutments, divided into two groups (n= 16: straight abutment, n= 21 anatomical abutment). The sets were submitted to cyclic loading (5 million) using servo-hydraulic equipment. Three sets from each group were subjected to bending tests to determine the maximum load resistance, which served as the parameter for comparison of the cyclic tests. We evaluated number of cycles, load and bending moment. Result Of the 31 abutments cyclically tested, 17 (54.8%) fractured in fewer than 5 million cycles; 8 (25.8%) of these were straight abutments, and 9 (29%) were anatomical. A total of 14 samples (45.2%) resisted the cyclic loading. According to Fisher's exact test, there was no difference between groups as the fracture. Conclusion Despite of the straight abutments have higher average load and bending moment on the anatomical, both types of abutments showed similar performance as the fracture strength in vitro.Universidade Estadual Paulista Júlio de Mesquita Filho2016-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016000500271Revista de Odontologia da UNESP v.45 n.5 2016reponame:Revista de Odontologia da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESP10.1590/1807-2577.08216info:eu-repo/semantics/openAccessGOIS-SANTOS,Vanessa Tavares deTRENTO,Cleverson LucianoSANTOS,Silvando Vieira dosSANTOS,Renan Celestino SilvaSANTOS,Victor SantanaGRIZA,Sandroeng2016-10-28T00:00:00Zoai:scielo:S1807-25772016000500271Revistahttps://www.revodontolunesp.com.br/PUBhttps://old.scielo.br/oai/scielo-oai.php||adriana@foar.unesp.br1807-25770101-1774opendoar:2016-10-28T00:00Revista de Odontologia da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system
title Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system
spellingShingle Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system
GOIS-SANTOS,Vanessa Tavares de
Dental implants
material resistance
mechanical phenomena
title_short Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system
title_full Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system
title_fullStr Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system
title_full_unstemmed Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system
title_sort Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system
author GOIS-SANTOS,Vanessa Tavares de
author_facet GOIS-SANTOS,Vanessa Tavares de
TRENTO,Cleverson Luciano
SANTOS,Silvando Vieira dos
SANTOS,Renan Celestino Silva
SANTOS,Victor Santana
GRIZA,Sandro
author_role author
author2 TRENTO,Cleverson Luciano
SANTOS,Silvando Vieira dos
SANTOS,Renan Celestino Silva
SANTOS,Victor Santana
GRIZA,Sandro
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv GOIS-SANTOS,Vanessa Tavares de
TRENTO,Cleverson Luciano
SANTOS,Silvando Vieira dos
SANTOS,Renan Celestino Silva
SANTOS,Victor Santana
GRIZA,Sandro
dc.subject.por.fl_str_mv Dental implants
material resistance
mechanical phenomena
topic Dental implants
material resistance
mechanical phenomena
description Abstract Background The study of the phenomenon of fatigue is essential because implant failures usually are caused by this process. Purpose The objective of this study was to examine the fatigue resistance of straight and anatomical abutments joints that were submitted to cyclic loads. Material and method We used 37 Morse taper implants and 37 abutments, divided into two groups (n= 16: straight abutment, n= 21 anatomical abutment). The sets were submitted to cyclic loading (5 million) using servo-hydraulic equipment. Three sets from each group were subjected to bending tests to determine the maximum load resistance, which served as the parameter for comparison of the cyclic tests. We evaluated number of cycles, load and bending moment. Result Of the 31 abutments cyclically tested, 17 (54.8%) fractured in fewer than 5 million cycles; 8 (25.8%) of these were straight abutments, and 9 (29%) were anatomical. A total of 14 samples (45.2%) resisted the cyclic loading. According to Fisher's exact test, there was no difference between groups as the fracture. Conclusion Despite of the straight abutments have higher average load and bending moment on the anatomical, both types of abutments showed similar performance as the fracture strength in vitro.
publishDate 2016
dc.date.none.fl_str_mv 2016-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016000500271
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016000500271
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1807-2577.08216
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Universidade Estadual Paulista Júlio de Mesquita Filho
publisher.none.fl_str_mv Universidade Estadual Paulista Júlio de Mesquita Filho
dc.source.none.fl_str_mv Revista de Odontologia da UNESP v.45 n.5 2016
reponame:Revista de Odontologia da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Revista de Odontologia da UNESP
collection Revista de Odontologia da UNESP
repository.name.fl_str_mv Revista de Odontologia da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv ||adriana@foar.unesp.br
_version_ 1748958559842861056