In Vitro Study on the influence of the light polymerization technique and appliance on the bond strength of intra-radicular dowels
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng por |
Título da fonte: | Brazilian Dental Science |
Texto Completo: | https://ojs.ict.unesp.br/index.php/cob/article/view/754 |
Resumo: | Purpose: The purpose of this study is to verify the influence of light curing type on retention force of direct technique and direct-indirect technique. Materials and Methods: Fourth bovine single root teeth with 12mm of length were used in this study. The roots were endodontically treated and randomly divided in four groups according to the light curing unit and technique used: group 1(direct technique, halogen lamp), group 2(direct technique, LED), group 3(direct-indirect technique, halogen lamp), group 4(direct-indirect technique, lamp). The retention force was determined sing a Universal Testing Machine (Instron). All data were analyzed using one-way analysis of variance (ANOVA) and Tukey test. After the test, the failure was examined and classified according to the fracture place: post/ resin; resin/dentin; mix. Results: Group 3 (246,05N ± 29,51) and 4(241,60N ± 28,95)4 (95,18N) did not show statistically difference but presented higher retention force than group 1 (142,30N ± 25,60) and 2 (178,56N ± 25,67). Most of fracture occurred in interface between dentin/resin. Conclusion: Based on the obtained results, it was concluded that adhesive cementation technique influenced in the retention of glass fiber post. |
id |
UNESP-20_34015454bc56ed079825adbe318326bf |
---|---|
oai_identifier_str |
oai:ojs.pkp.sfu.ca:article/754 |
network_acronym_str |
UNESP-20 |
network_name_str |
Brazilian Dental Science |
repository_id_str |
|
spelling |
In Vitro Study on the influence of the light polymerization technique and appliance on the bond strength of intra-radicular dowelsFiber postRetention forceDirect methodDirect-indirect methodHalogen lampLED. Purpose: The purpose of this study is to verify the influence of light curing type on retention force of direct technique and direct-indirect technique. Materials and Methods: Fourth bovine single root teeth with 12mm of length were used in this study. The roots were endodontically treated and randomly divided in four groups according to the light curing unit and technique used: group 1(direct technique, halogen lamp), group 2(direct technique, LED), group 3(direct-indirect technique, halogen lamp), group 4(direct-indirect technique, lamp). The retention force was determined sing a Universal Testing Machine (Instron). All data were analyzed using one-way analysis of variance (ANOVA) and Tukey test. After the test, the failure was examined and classified according to the fracture place: post/ resin; resin/dentin; mix. Results: Group 3 (246,05N ± 29,51) and 4(241,60N ± 28,95)4 (95,18N) did not show statistically difference but presented higher retention force than group 1 (142,30N ± 25,60) and 2 (178,56N ± 25,67). Most of fracture occurred in interface between dentin/resin. Conclusion: Based on the obtained results, it was concluded that adhesive cementation technique influenced in the retention of glass fiber post.Institute of Science and Technology of São José dos Campos2012-10-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/mswordimage/jpegapplication/mswordhttps://ojs.ict.unesp.br/index.php/cob/article/view/75410.14295/bds.2012.v15i2.754Brazilian Dental Science; Vol. 15 No. 2 (2012): Apr. - Jun. / 2012; 12-18Brazilian Dental Science; v. 15 n. 2 (2012): Apr. - Jun. / 2012; 12-182178-6011reponame:Brazilian Dental Scienceinstname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)instacron:UNESPengporhttps://ojs.ict.unesp.br/index.php/cob/article/view/754/711https://ojs.ict.unesp.br/index.php/cob/article/view/754/1688https://ojs.ict.unesp.br/index.php/cob/article/view/754/1689https://ojs.ict.unesp.br/index.php/cob/article/view/754/1690Nagase, Denis YudiMorimoto, SusanaAgra, Carlos MartinsVieira, Glauco FioranelliOda, Margarethinfo:eu-repo/semantics/openAccess2020-01-28T12:42:00Zoai:ojs.pkp.sfu.ca:article/754Revistahttp://bds.ict.unesp.br/PUBhttp://ojs.fosjc.unesp.br/index.php/index/oaisergio@fosjc.unesp.br||sergio@fosjc.unesp.br2178-60112178-6011opendoar:2022-11-08T16:29:49.504619Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)true |
dc.title.none.fl_str_mv |
In Vitro Study on the influence of the light polymerization technique and appliance on the bond strength of intra-radicular dowels |
title |
In Vitro Study on the influence of the light polymerization technique and appliance on the bond strength of intra-radicular dowels |
spellingShingle |
In Vitro Study on the influence of the light polymerization technique and appliance on the bond strength of intra-radicular dowels Nagase, Denis Yudi Fiber post Retention force Direct method Direct-indirect method Halogen lamp LED. |
title_short |
In Vitro Study on the influence of the light polymerization technique and appliance on the bond strength of intra-radicular dowels |
title_full |
In Vitro Study on the influence of the light polymerization technique and appliance on the bond strength of intra-radicular dowels |
title_fullStr |
In Vitro Study on the influence of the light polymerization technique and appliance on the bond strength of intra-radicular dowels |
title_full_unstemmed |
In Vitro Study on the influence of the light polymerization technique and appliance on the bond strength of intra-radicular dowels |
title_sort |
In Vitro Study on the influence of the light polymerization technique and appliance on the bond strength of intra-radicular dowels |
author |
Nagase, Denis Yudi |
author_facet |
Nagase, Denis Yudi Morimoto, Susana Agra, Carlos Martins Vieira, Glauco Fioranelli Oda, Margareth |
author_role |
author |
author2 |
Morimoto, Susana Agra, Carlos Martins Vieira, Glauco Fioranelli Oda, Margareth |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Nagase, Denis Yudi Morimoto, Susana Agra, Carlos Martins Vieira, Glauco Fioranelli Oda, Margareth |
dc.subject.por.fl_str_mv |
Fiber post Retention force Direct method Direct-indirect method Halogen lamp LED. |
topic |
Fiber post Retention force Direct method Direct-indirect method Halogen lamp LED. |
description |
Purpose: The purpose of this study is to verify the influence of light curing type on retention force of direct technique and direct-indirect technique. Materials and Methods: Fourth bovine single root teeth with 12mm of length were used in this study. The roots were endodontically treated and randomly divided in four groups according to the light curing unit and technique used: group 1(direct technique, halogen lamp), group 2(direct technique, LED), group 3(direct-indirect technique, halogen lamp), group 4(direct-indirect technique, lamp). The retention force was determined sing a Universal Testing Machine (Instron). All data were analyzed using one-way analysis of variance (ANOVA) and Tukey test. After the test, the failure was examined and classified according to the fracture place: post/ resin; resin/dentin; mix. Results: Group 3 (246,05N ± 29,51) and 4(241,60N ± 28,95)4 (95,18N) did not show statistically difference but presented higher retention force than group 1 (142,30N ± 25,60) and 2 (178,56N ± 25,67). Most of fracture occurred in interface between dentin/resin. Conclusion: Based on the obtained results, it was concluded that adhesive cementation technique influenced in the retention of glass fiber post. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-10-31 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://ojs.ict.unesp.br/index.php/cob/article/view/754 10.14295/bds.2012.v15i2.754 |
url |
https://ojs.ict.unesp.br/index.php/cob/article/view/754 |
identifier_str_mv |
10.14295/bds.2012.v15i2.754 |
dc.language.iso.fl_str_mv |
eng por |
language |
eng por |
dc.relation.none.fl_str_mv |
https://ojs.ict.unesp.br/index.php/cob/article/view/754/711 https://ojs.ict.unesp.br/index.php/cob/article/view/754/1688 https://ojs.ict.unesp.br/index.php/cob/article/view/754/1689 https://ojs.ict.unesp.br/index.php/cob/article/view/754/1690 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf application/msword image/jpeg application/msword |
dc.publisher.none.fl_str_mv |
Institute of Science and Technology of São José dos Campos |
publisher.none.fl_str_mv |
Institute of Science and Technology of São José dos Campos |
dc.source.none.fl_str_mv |
Brazilian Dental Science; Vol. 15 No. 2 (2012): Apr. - Jun. / 2012; 12-18 Brazilian Dental Science; v. 15 n. 2 (2012): Apr. - Jun. / 2012; 12-18 2178-6011 reponame:Brazilian Dental Science instname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Brazilian Dental Science |
collection |
Brazilian Dental Science |
repository.name.fl_str_mv |
Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) |
repository.mail.fl_str_mv |
sergio@fosjc.unesp.br||sergio@fosjc.unesp.br |
_version_ |
1788346898425315328 |