Assessment of dental implant site dimensions in cone beam computed tomography systems
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Dental Science |
Texto Completo: | https://ojs.ict.unesp.br/index.php/cob/article/view/990 |
Resumo: | Objective: The aim was to investigate the accuracy of linear measurements the mandibular ridge recorded using two CBCT systems. Materials and Methods: Eleven human dry skull were used in which mandibles were chosen to measure width and height in 6 sites. Before scanning, the points were marked using barium sulfate radiopaque contrast media. Mandible imaging was done using two systems: Newtom3G and Cranex3D. Alveolar ridge dimensions were recorded by two observers under uniform condition using special software for each system. The measurement errors and inter-examiner reliability were calculated for each modality and compared with each other and analyzed via SPSS software version 18. The level of significance was set at P< 0.05. Results: The overall mean absolute error was 0.08 mm for Cranex system and 0.5 for Newtom system. The mean absolute error of two systems had no statistically significant difference in comparison with each other or with the gold standard. The statistical analysis showed high inter-observer reliability (P < 0.05). Conclusion: CBCT is highly accurate and reproducible in linear measurements in the axial and coronal images planes and in different areas of the maxillofacial region.Keywords: Barium sulfate; Cranex3D; Cone beam computed tomography; Dental implant; Newtom3G. |
id |
UNESP-20_4dc6f26db060fc62e50dbdcd4cc33f90 |
---|---|
oai_identifier_str |
oai:ojs.pkp.sfu.ca:article/990 |
network_acronym_str |
UNESP-20 |
network_name_str |
Brazilian Dental Science |
repository_id_str |
|
spelling |
Assessment of dental implant site dimensions in cone beam computed tomography systemsObjective: The aim was to investigate the accuracy of linear measurements the mandibular ridge recorded using two CBCT systems. Materials and Methods: Eleven human dry skull were used in which mandibles were chosen to measure width and height in 6 sites. Before scanning, the points were marked using barium sulfate radiopaque contrast media. Mandible imaging was done using two systems: Newtom3G and Cranex3D. Alveolar ridge dimensions were recorded by two observers under uniform condition using special software for each system. The measurement errors and inter-examiner reliability were calculated for each modality and compared with each other and analyzed via SPSS software version 18. The level of significance was set at P< 0.05. Results: The overall mean absolute error was 0.08 mm for Cranex system and 0.5 for Newtom system. The mean absolute error of two systems had no statistically significant difference in comparison with each other or with the gold standard. The statistical analysis showed high inter-observer reliability (P < 0.05). Conclusion: CBCT is highly accurate and reproducible in linear measurements in the axial and coronal images planes and in different areas of the maxillofacial region.Keywords: Barium sulfate; Cranex3D; Cone beam computed tomography; Dental implant; Newtom3G.Institute of Science and Technology of São José dos Campos2014-09-15info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/mswordimage/jpegimage/jpegimage/jpegimage/jpegimage/jpegimage/jpegapplication/mswordapplication/mswordhttps://ojs.ict.unesp.br/index.php/cob/article/view/99010.14295/bds.2014.v17i3.990Brazilian Dental Science; Vol. 17 No. 3 (2014): Jul. - Sep. / 2014 - Published August 2014; 74-82Brazilian Dental Science; v. 17 n. 3 (2014): Jul. - Sep. / 2014 - Published August 2014; 74-822178-6011reponame:Brazilian Dental Scienceinstname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)instacron:UNESPenghttps://ojs.ict.unesp.br/index.php/cob/article/view/990/884https://ojs.ict.unesp.br/index.php/cob/article/view/990/2055https://ojs.ict.unesp.br/index.php/cob/article/view/990/2056https://ojs.ict.unesp.br/index.php/cob/article/view/990/2057https://ojs.ict.unesp.br/index.php/cob/article/view/990/2058https://ojs.ict.unesp.br/index.php/cob/article/view/990/2059https://ojs.ict.unesp.br/index.php/cob/article/view/990/2060https://ojs.ict.unesp.br/index.php/cob/article/view/990/2061https://ojs.ict.unesp.br/index.php/cob/article/view/990/2083https://ojs.ict.unesp.br/index.php/cob/article/view/990/2084Shokri, AbbasKhajeh, SamiraFalah-kooshki, SepidehOstovarrad, FarzanehKarimi, AtenaKhavid, Atefehinfo:eu-repo/semantics/openAccess2020-01-28T12:31:07Zoai:ojs.pkp.sfu.ca:article/990Revistahttp://bds.ict.unesp.br/PUBhttp://ojs.fosjc.unesp.br/index.php/index/oaisergio@fosjc.unesp.br||sergio@fosjc.unesp.br2178-60112178-6011opendoar:2022-11-08T16:29:56.977748Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)true |
dc.title.none.fl_str_mv |
Assessment of dental implant site dimensions in cone beam computed tomography systems |
title |
Assessment of dental implant site dimensions in cone beam computed tomography systems |
spellingShingle |
Assessment of dental implant site dimensions in cone beam computed tomography systems Shokri, Abbas |
title_short |
Assessment of dental implant site dimensions in cone beam computed tomography systems |
title_full |
Assessment of dental implant site dimensions in cone beam computed tomography systems |
title_fullStr |
Assessment of dental implant site dimensions in cone beam computed tomography systems |
title_full_unstemmed |
Assessment of dental implant site dimensions in cone beam computed tomography systems |
title_sort |
Assessment of dental implant site dimensions in cone beam computed tomography systems |
author |
Shokri, Abbas |
author_facet |
Shokri, Abbas Khajeh, Samira Falah-kooshki, Sepideh Ostovarrad, Farzaneh Karimi, Atena Khavid, Atefeh |
author_role |
author |
author2 |
Khajeh, Samira Falah-kooshki, Sepideh Ostovarrad, Farzaneh Karimi, Atena Khavid, Atefeh |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Shokri, Abbas Khajeh, Samira Falah-kooshki, Sepideh Ostovarrad, Farzaneh Karimi, Atena Khavid, Atefeh |
description |
Objective: The aim was to investigate the accuracy of linear measurements the mandibular ridge recorded using two CBCT systems. Materials and Methods: Eleven human dry skull were used in which mandibles were chosen to measure width and height in 6 sites. Before scanning, the points were marked using barium sulfate radiopaque contrast media. Mandible imaging was done using two systems: Newtom3G and Cranex3D. Alveolar ridge dimensions were recorded by two observers under uniform condition using special software for each system. The measurement errors and inter-examiner reliability were calculated for each modality and compared with each other and analyzed via SPSS software version 18. The level of significance was set at P< 0.05. Results: The overall mean absolute error was 0.08 mm for Cranex system and 0.5 for Newtom system. The mean absolute error of two systems had no statistically significant difference in comparison with each other or with the gold standard. The statistical analysis showed high inter-observer reliability (P < 0.05). Conclusion: CBCT is highly accurate and reproducible in linear measurements in the axial and coronal images planes and in different areas of the maxillofacial region.Keywords: Barium sulfate; Cranex3D; Cone beam computed tomography; Dental implant; Newtom3G. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-09-15 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://ojs.ict.unesp.br/index.php/cob/article/view/990 10.14295/bds.2014.v17i3.990 |
url |
https://ojs.ict.unesp.br/index.php/cob/article/view/990 |
identifier_str_mv |
10.14295/bds.2014.v17i3.990 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://ojs.ict.unesp.br/index.php/cob/article/view/990/884 https://ojs.ict.unesp.br/index.php/cob/article/view/990/2055 https://ojs.ict.unesp.br/index.php/cob/article/view/990/2056 https://ojs.ict.unesp.br/index.php/cob/article/view/990/2057 https://ojs.ict.unesp.br/index.php/cob/article/view/990/2058 https://ojs.ict.unesp.br/index.php/cob/article/view/990/2059 https://ojs.ict.unesp.br/index.php/cob/article/view/990/2060 https://ojs.ict.unesp.br/index.php/cob/article/view/990/2061 https://ojs.ict.unesp.br/index.php/cob/article/view/990/2083 https://ojs.ict.unesp.br/index.php/cob/article/view/990/2084 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf application/msword image/jpeg image/jpeg image/jpeg image/jpeg image/jpeg image/jpeg application/msword application/msword |
dc.publisher.none.fl_str_mv |
Institute of Science and Technology of São José dos Campos |
publisher.none.fl_str_mv |
Institute of Science and Technology of São José dos Campos |
dc.source.none.fl_str_mv |
Brazilian Dental Science; Vol. 17 No. 3 (2014): Jul. - Sep. / 2014 - Published August 2014; 74-82 Brazilian Dental Science; v. 17 n. 3 (2014): Jul. - Sep. / 2014 - Published August 2014; 74-82 2178-6011 reponame:Brazilian Dental Science instname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Brazilian Dental Science |
collection |
Brazilian Dental Science |
repository.name.fl_str_mv |
Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) |
repository.mail.fl_str_mv |
sergio@fosjc.unesp.br||sergio@fosjc.unesp.br |
_version_ |
1788346898960089088 |