Effect of thickness on fluorescence of resin-composites and dental substrates
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Dental Science |
Texto Completo: | https://ojs.ict.unesp.br/index.php/cob/article/view/1282 |
Resumo: | Objective: This study evaluated the effect of thickness on fluorescence of resin composites and tooth substrates (enamel and dentin). Material and methods: Ninety bovine incisors were used, resulting in 45 dentin and 45 enamel disks (6 mm diameter and 0.5, 1, or 1.5 mm in thickness). Ninety discs of Charisma, Filtek Z350 and IPS Empress Direct (for enamel and dentin) resins at same dimensions were built. Fluorescence measurements were performed using a fluorescence spectrophotometer (RF-5301PC, Shimadzu Corp) with excitation at 365 nm. Data were submitted to 2-way ANOVA and Tukey’s post hoc tests (? = 0.05). Results: The 2- way - ANOVA revealed statistically significant differences for all factors, as well as the interaction between them (p <0.05). Dentin specimens (1.5 mm) showed highest fluorescence (128.33 A.U.), while Filtek Z350 (dentin - 1.0 mm) showed the lowest fluorescence (29.84 A.U.). Thickness influenced fluorescence values of enamel substrate. Conclusion: The thickness influenced fluorescence of enamel and all resin composite assessed showed fluorescence lower than natural dentin.KeywordsDental enamel; Dental resins; Dentin; Spectrometry, Fluorescence. |
id |
UNESP-20_71164f68dc218e43ef37baf842fb9f92 |
---|---|
oai_identifier_str |
oai:ojs.pkp.sfu.ca:article/1282 |
network_acronym_str |
UNESP-20 |
network_name_str |
Brazilian Dental Science |
repository_id_str |
|
spelling |
Effect of thickness on fluorescence of resin-composites and dental substratesObjective: This study evaluated the effect of thickness on fluorescence of resin composites and tooth substrates (enamel and dentin). Material and methods: Ninety bovine incisors were used, resulting in 45 dentin and 45 enamel disks (6 mm diameter and 0.5, 1, or 1.5 mm in thickness). Ninety discs of Charisma, Filtek Z350 and IPS Empress Direct (for enamel and dentin) resins at same dimensions were built. Fluorescence measurements were performed using a fluorescence spectrophotometer (RF-5301PC, Shimadzu Corp) with excitation at 365 nm. Data were submitted to 2-way ANOVA and Tukey’s post hoc tests (? = 0.05). Results: The 2- way - ANOVA revealed statistically significant differences for all factors, as well as the interaction between them (p <0.05). Dentin specimens (1.5 mm) showed highest fluorescence (128.33 A.U.), while Filtek Z350 (dentin - 1.0 mm) showed the lowest fluorescence (29.84 A.U.). Thickness influenced fluorescence values of enamel substrate. Conclusion: The thickness influenced fluorescence of enamel and all resin composite assessed showed fluorescence lower than natural dentin.KeywordsDental enamel; Dental resins; Dentin; Spectrometry, Fluorescence.Institute of Science and Technology of São José dos Campos2016-09-29info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/mswordimage/jpegimage/jpegimage/jpegapplication/pdfhttps://ojs.ict.unesp.br/index.php/cob/article/view/128210.14295/bds.2016.v19i3.1282Brazilian Dental Science; Vol. 19 No. 3 (2016): Jul. - Sep. / 2016 - Published September 2016; 53-58Brazilian Dental Science; v. 19 n. 3 (2016): Jul. - Sep. / 2016 - Published September 2016; 53-582178-6011reponame:Brazilian Dental Scienceinstname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)instacron:UNESPenghttps://ojs.ict.unesp.br/index.php/cob/article/view/1282/1048https://ojs.ict.unesp.br/index.php/cob/article/view/1282/2722https://ojs.ict.unesp.br/index.php/cob/article/view/1282/2723https://ojs.ict.unesp.br/index.php/cob/article/view/1282/2724https://ojs.ict.unesp.br/index.php/cob/article/view/1282/2725https://ojs.ict.unesp.br/index.php/cob/article/view/1282/2726Copyright (c) 2016 Brazilian Dental Scienceinfo:eu-repo/semantics/openAccessTavares, CarlaTavares, LuizaCorreia, AylaBresciani, EduardoCaneppele, Taciana2020-01-28T12:18:16Zoai:ojs.pkp.sfu.ca:article/1282Revistahttp://bds.ict.unesp.br/PUBhttp://ojs.fosjc.unesp.br/index.php/index/oaisergio@fosjc.unesp.br||sergio@fosjc.unesp.br2178-60112178-6011opendoar:2022-11-08T16:30:07.640521Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)true |
dc.title.none.fl_str_mv |
Effect of thickness on fluorescence of resin-composites and dental substrates |
title |
Effect of thickness on fluorescence of resin-composites and dental substrates |
spellingShingle |
Effect of thickness on fluorescence of resin-composites and dental substrates Tavares, Carla |
title_short |
Effect of thickness on fluorescence of resin-composites and dental substrates |
title_full |
Effect of thickness on fluorescence of resin-composites and dental substrates |
title_fullStr |
Effect of thickness on fluorescence of resin-composites and dental substrates |
title_full_unstemmed |
Effect of thickness on fluorescence of resin-composites and dental substrates |
title_sort |
Effect of thickness on fluorescence of resin-composites and dental substrates |
author |
Tavares, Carla |
author_facet |
Tavares, Carla Tavares, Luiza Correia, Ayla Bresciani, Eduardo Caneppele, Taciana |
author_role |
author |
author2 |
Tavares, Luiza Correia, Ayla Bresciani, Eduardo Caneppele, Taciana |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Tavares, Carla Tavares, Luiza Correia, Ayla Bresciani, Eduardo Caneppele, Taciana |
description |
Objective: This study evaluated the effect of thickness on fluorescence of resin composites and tooth substrates (enamel and dentin). Material and methods: Ninety bovine incisors were used, resulting in 45 dentin and 45 enamel disks (6 mm diameter and 0.5, 1, or 1.5 mm in thickness). Ninety discs of Charisma, Filtek Z350 and IPS Empress Direct (for enamel and dentin) resins at same dimensions were built. Fluorescence measurements were performed using a fluorescence spectrophotometer (RF-5301PC, Shimadzu Corp) with excitation at 365 nm. Data were submitted to 2-way ANOVA and Tukey’s post hoc tests (? = 0.05). Results: The 2- way - ANOVA revealed statistically significant differences for all factors, as well as the interaction between them (p <0.05). Dentin specimens (1.5 mm) showed highest fluorescence (128.33 A.U.), while Filtek Z350 (dentin - 1.0 mm) showed the lowest fluorescence (29.84 A.U.). Thickness influenced fluorescence values of enamel substrate. Conclusion: The thickness influenced fluorescence of enamel and all resin composite assessed showed fluorescence lower than natural dentin.KeywordsDental enamel; Dental resins; Dentin; Spectrometry, Fluorescence. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-09-29 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://ojs.ict.unesp.br/index.php/cob/article/view/1282 10.14295/bds.2016.v19i3.1282 |
url |
https://ojs.ict.unesp.br/index.php/cob/article/view/1282 |
identifier_str_mv |
10.14295/bds.2016.v19i3.1282 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://ojs.ict.unesp.br/index.php/cob/article/view/1282/1048 https://ojs.ict.unesp.br/index.php/cob/article/view/1282/2722 https://ojs.ict.unesp.br/index.php/cob/article/view/1282/2723 https://ojs.ict.unesp.br/index.php/cob/article/view/1282/2724 https://ojs.ict.unesp.br/index.php/cob/article/view/1282/2725 https://ojs.ict.unesp.br/index.php/cob/article/view/1282/2726 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2016 Brazilian Dental Science info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2016 Brazilian Dental Science |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf application/msword image/jpeg image/jpeg image/jpeg application/pdf |
dc.publisher.none.fl_str_mv |
Institute of Science and Technology of São José dos Campos |
publisher.none.fl_str_mv |
Institute of Science and Technology of São José dos Campos |
dc.source.none.fl_str_mv |
Brazilian Dental Science; Vol. 19 No. 3 (2016): Jul. - Sep. / 2016 - Published September 2016; 53-58 Brazilian Dental Science; v. 19 n. 3 (2016): Jul. - Sep. / 2016 - Published September 2016; 53-58 2178-6011 reponame:Brazilian Dental Science instname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Brazilian Dental Science |
collection |
Brazilian Dental Science |
repository.name.fl_str_mv |
Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) |
repository.mail.fl_str_mv |
sergio@fosjc.unesp.br||sergio@fosjc.unesp.br |
_version_ |
1788346899740229632 |