Influence of CAD/CAM Material and Preparation Design on the Long-term Fracture Resistance of Endocrowns Restoring Maxillary Premolars

Detalhes bibliográficos
Autor(a) principal: Foad, Ahmed Mohsen
Data de Publicação: 2020
Outros Autores: Hamdy, Amina, Abd el Fatah, Ghada, Aboelfadl, Ahmad
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Science
Texto Completo: https://ojs.ict.unesp.br/index.php/cob/article/view/2060
Resumo: Objective: To evaluate the effect of different occlusal preparation designs and CAD/CAM materials on the fracture resistance of maxillary premolars endcrowns. Materials and Methods: sixty-four endodontically treated upper first premolars were randomly divided into four groups according to ceramic materials (Vita Enamic and IPS emax CAD) and occlusal preparation designs (Anatomical and horizontal butt joint). After teeth preparation, the restorations were all made by CAD/CAM system (Cerec MCXL). Half of each group had undergone cyclic fatigue testing of 105 cycles with 50N loading force at a frequency of 0.5Hz in a mechatronic chewing simulator machine, and then all samples were loaded to fracture using a universal testing machine with a cross head speed of 0.5mm/min recording the fracture resistance values in N . The specimens were measured and statistically analyzed using using three-way analyses of variance (ANOVA), followed by serial two-way and one-way ANOVAs at each level of the study. P-values were adjusted for multiple comparisons using BENFORRONI correction and the significance level was set at P ? 0.05 for all tests. Results: Vita Enamic endocrowns showed higher fracture resistance values than IPS e max specimens. Conclusions: Vita Enamic endocrowns with anatomical preparations were found to be more favourable restoring endodontically treated maxillary premolars. KEYWORDSEndocrowns; All-Ceramic; Fracture; Cyclic loading; CAD/CAM
id UNESP-20_8d426746f471c8cfdc18761169674507
oai_identifier_str oai:ojs.pkp.sfu.ca:article/2060
network_acronym_str UNESP-20
network_name_str Brazilian Dental Science
repository_id_str
spelling Influence of CAD/CAM Material and Preparation Design on the Long-term Fracture Resistance of Endocrowns Restoring Maxillary PremolarsObjective: To evaluate the effect of different occlusal preparation designs and CAD/CAM materials on the fracture resistance of maxillary premolars endcrowns. Materials and Methods: sixty-four endodontically treated upper first premolars were randomly divided into four groups according to ceramic materials (Vita Enamic and IPS emax CAD) and occlusal preparation designs (Anatomical and horizontal butt joint). After teeth preparation, the restorations were all made by CAD/CAM system (Cerec MCXL). Half of each group had undergone cyclic fatigue testing of 105 cycles with 50N loading force at a frequency of 0.5Hz in a mechatronic chewing simulator machine, and then all samples were loaded to fracture using a universal testing machine with a cross head speed of 0.5mm/min recording the fracture resistance values in N . The specimens were measured and statistically analyzed using using three-way analyses of variance (ANOVA), followed by serial two-way and one-way ANOVAs at each level of the study. P-values were adjusted for multiple comparisons using BENFORRONI correction and the significance level was set at P ? 0.05 for all tests. Results: Vita Enamic endocrowns showed higher fracture resistance values than IPS e max specimens. Conclusions: Vita Enamic endocrowns with anatomical preparations were found to be more favourable restoring endodontically treated maxillary premolars. KEYWORDSEndocrowns; All-Ceramic; Fracture; Cyclic loading; CAD/CAM Institute of Science and Technology of São José dos Campos2020-09-30info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://ojs.ict.unesp.br/index.php/cob/article/view/206010.14295/bds.2020.v23i4.2060Brazilian Dental Science; Vol. 23 No. 4 (2020): Oct - Dec / 2020 - published Sep 2020; 9pBrazilian Dental Science; v. 23 n. 4 (2020): Oct - Dec / 2020 - published Sep 2020; 9p2178-6011reponame:Brazilian Dental Scienceinstname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)instacron:UNESPenghttps://ojs.ict.unesp.br/index.php/cob/article/view/2060/4195Copyright (c) 2020 Brazilian Dental Scienceinfo:eu-repo/semantics/openAccessFoad, Ahmed MohsenHamdy, AminaAbd el Fatah, GhadaAboelfadl, Ahmad2020-09-30T23:03:30Zoai:ojs.pkp.sfu.ca:article/2060Revistahttp://bds.ict.unesp.br/PUBhttp://ojs.fosjc.unesp.br/index.php/index/oaisergio@fosjc.unesp.br||sergio@fosjc.unesp.br2178-60112178-6011opendoar:2022-11-08T16:30:30.459786Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)true
dc.title.none.fl_str_mv Influence of CAD/CAM Material and Preparation Design on the Long-term Fracture Resistance of Endocrowns Restoring Maxillary Premolars
title Influence of CAD/CAM Material and Preparation Design on the Long-term Fracture Resistance of Endocrowns Restoring Maxillary Premolars
spellingShingle Influence of CAD/CAM Material and Preparation Design on the Long-term Fracture Resistance of Endocrowns Restoring Maxillary Premolars
Foad, Ahmed Mohsen
title_short Influence of CAD/CAM Material and Preparation Design on the Long-term Fracture Resistance of Endocrowns Restoring Maxillary Premolars
title_full Influence of CAD/CAM Material and Preparation Design on the Long-term Fracture Resistance of Endocrowns Restoring Maxillary Premolars
title_fullStr Influence of CAD/CAM Material and Preparation Design on the Long-term Fracture Resistance of Endocrowns Restoring Maxillary Premolars
title_full_unstemmed Influence of CAD/CAM Material and Preparation Design on the Long-term Fracture Resistance of Endocrowns Restoring Maxillary Premolars
title_sort Influence of CAD/CAM Material and Preparation Design on the Long-term Fracture Resistance of Endocrowns Restoring Maxillary Premolars
author Foad, Ahmed Mohsen
author_facet Foad, Ahmed Mohsen
Hamdy, Amina
Abd el Fatah, Ghada
Aboelfadl, Ahmad
author_role author
author2 Hamdy, Amina
Abd el Fatah, Ghada
Aboelfadl, Ahmad
author2_role author
author
author
dc.contributor.author.fl_str_mv Foad, Ahmed Mohsen
Hamdy, Amina
Abd el Fatah, Ghada
Aboelfadl, Ahmad
description Objective: To evaluate the effect of different occlusal preparation designs and CAD/CAM materials on the fracture resistance of maxillary premolars endcrowns. Materials and Methods: sixty-four endodontically treated upper first premolars were randomly divided into four groups according to ceramic materials (Vita Enamic and IPS emax CAD) and occlusal preparation designs (Anatomical and horizontal butt joint). After teeth preparation, the restorations were all made by CAD/CAM system (Cerec MCXL). Half of each group had undergone cyclic fatigue testing of 105 cycles with 50N loading force at a frequency of 0.5Hz in a mechatronic chewing simulator machine, and then all samples were loaded to fracture using a universal testing machine with a cross head speed of 0.5mm/min recording the fracture resistance values in N . The specimens were measured and statistically analyzed using using three-way analyses of variance (ANOVA), followed by serial two-way and one-way ANOVAs at each level of the study. P-values were adjusted for multiple comparisons using BENFORRONI correction and the significance level was set at P ? 0.05 for all tests. Results: Vita Enamic endocrowns showed higher fracture resistance values than IPS e max specimens. Conclusions: Vita Enamic endocrowns with anatomical preparations were found to be more favourable restoring endodontically treated maxillary premolars. KEYWORDSEndocrowns; All-Ceramic; Fracture; Cyclic loading; CAD/CAM
publishDate 2020
dc.date.none.fl_str_mv 2020-09-30
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://ojs.ict.unesp.br/index.php/cob/article/view/2060
10.14295/bds.2020.v23i4.2060
url https://ojs.ict.unesp.br/index.php/cob/article/view/2060
identifier_str_mv 10.14295/bds.2020.v23i4.2060
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://ojs.ict.unesp.br/index.php/cob/article/view/2060/4195
dc.rights.driver.fl_str_mv Copyright (c) 2020 Brazilian Dental Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2020 Brazilian Dental Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Institute of Science and Technology of São José dos Campos
publisher.none.fl_str_mv Institute of Science and Technology of São José dos Campos
dc.source.none.fl_str_mv Brazilian Dental Science; Vol. 23 No. 4 (2020): Oct - Dec / 2020 - published Sep 2020; 9p
Brazilian Dental Science; v. 23 n. 4 (2020): Oct - Dec / 2020 - published Sep 2020; 9p
2178-6011
reponame:Brazilian Dental Science
instname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Brazilian Dental Science
collection Brazilian Dental Science
repository.name.fl_str_mv Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
repository.mail.fl_str_mv sergio@fosjc.unesp.br||sergio@fosjc.unesp.br
_version_ 1788346901476671488