Flow injection spectrophotometric determination of adrenaline using a solid-phase reactor containing triiodide ions immobilized in an anion-exchange resin

Detalhes bibliográficos
Autor(a) principal: Vieira,H. J.
Data de Publicação: 2004
Outros Autores: Fatibello-Filho,O.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Eclética Química
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702004000100010
Resumo: A flow injection spectrophotometric procedure with on-line solid-phase reactor containing ion triiodide immobilized in an anion-exchange resin is proposed for the determination of adrenaline (epinephrine) in pharmaceutical products. Adrenaline is oxidized by triiodide ion immobilized in an anionic-exchange resin yielding adrenochrome which is transported by the carrier solution and detected at a wavelength of 488 nm. Adrenaline was determined in three pharmaceutical products in the 6.4 x 10-6 to 3.0 x 10-4 mol L-1 concentration range with a detection limit of 4.8 x 10-7 mol L-1. The recovery of this analyte in three samples ranged from 96.0 to 105 %. The analytical frequency was 80 determinations per hour and the RSDs were less than 1 % for adrenaline concentrations of 6.4 x 10-5 and 2.0 x 10-4 mol L-1 (n=10). A paired t-test showed that all results obtained for adrenaline in commercial formulations using the proposed flow injection procedure and a spectrophotometric batch procedure agree at the 95% confidence level.
id UNESP-29_963c747fc5ed785be0ed185fb882a179
oai_identifier_str oai:scielo:S0100-46702004000100010
network_acronym_str UNESP-29
network_name_str Eclética Química
repository_id_str
spelling Flow injection spectrophotometric determination of adrenaline using a solid-phase reactor containing triiodide ions immobilized in an anion-exchange resinadrenalineflow injection spectrophotometrysolid-phase reactorpharmaceutical formulationstriiodide ionsA flow injection spectrophotometric procedure with on-line solid-phase reactor containing ion triiodide immobilized in an anion-exchange resin is proposed for the determination of adrenaline (epinephrine) in pharmaceutical products. Adrenaline is oxidized by triiodide ion immobilized in an anionic-exchange resin yielding adrenochrome which is transported by the carrier solution and detected at a wavelength of 488 nm. Adrenaline was determined in three pharmaceutical products in the 6.4 x 10-6 to 3.0 x 10-4 mol L-1 concentration range with a detection limit of 4.8 x 10-7 mol L-1. The recovery of this analyte in three samples ranged from 96.0 to 105 %. The analytical frequency was 80 determinations per hour and the RSDs were less than 1 % for adrenaline concentrations of 6.4 x 10-5 and 2.0 x 10-4 mol L-1 (n=10). A paired t-test showed that all results obtained for adrenaline in commercial formulations using the proposed flow injection procedure and a spectrophotometric batch procedure agree at the 95% confidence level.Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP2004-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702004000100010Eclética Química v.29 n.1 2004reponame:Eclética Químicainstname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)instacron:UNESP10.1590/S0100-46702004000100010info:eu-repo/semantics/openAccessVieira,H. J.Fatibello-Filho,O.eng2004-11-03T00:00:00Zoai:scielo:S0100-46702004000100010Revistahttp://revista.iq.unesp.br/ojs/index.php/ecletica/PUBhttps://revista.iq.unesp.br/ojs/index.php/ecletica/oaiecletica@ctrlk.com.br||ecletica@iq.unesp.br1678-46181678-4618opendoar:2004-11-03T00:00Eclética Química - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)false
dc.title.none.fl_str_mv Flow injection spectrophotometric determination of adrenaline using a solid-phase reactor containing triiodide ions immobilized in an anion-exchange resin
title Flow injection spectrophotometric determination of adrenaline using a solid-phase reactor containing triiodide ions immobilized in an anion-exchange resin
spellingShingle Flow injection spectrophotometric determination of adrenaline using a solid-phase reactor containing triiodide ions immobilized in an anion-exchange resin
Vieira,H. J.
adrenaline
flow injection spectrophotometry
solid-phase reactor
pharmaceutical formulations
triiodide ions
title_short Flow injection spectrophotometric determination of adrenaline using a solid-phase reactor containing triiodide ions immobilized in an anion-exchange resin
title_full Flow injection spectrophotometric determination of adrenaline using a solid-phase reactor containing triiodide ions immobilized in an anion-exchange resin
title_fullStr Flow injection spectrophotometric determination of adrenaline using a solid-phase reactor containing triiodide ions immobilized in an anion-exchange resin
title_full_unstemmed Flow injection spectrophotometric determination of adrenaline using a solid-phase reactor containing triiodide ions immobilized in an anion-exchange resin
title_sort Flow injection spectrophotometric determination of adrenaline using a solid-phase reactor containing triiodide ions immobilized in an anion-exchange resin
author Vieira,H. J.
author_facet Vieira,H. J.
Fatibello-Filho,O.
author_role author
author2 Fatibello-Filho,O.
author2_role author
dc.contributor.author.fl_str_mv Vieira,H. J.
Fatibello-Filho,O.
dc.subject.por.fl_str_mv adrenaline
flow injection spectrophotometry
solid-phase reactor
pharmaceutical formulations
triiodide ions
topic adrenaline
flow injection spectrophotometry
solid-phase reactor
pharmaceutical formulations
triiodide ions
description A flow injection spectrophotometric procedure with on-line solid-phase reactor containing ion triiodide immobilized in an anion-exchange resin is proposed for the determination of adrenaline (epinephrine) in pharmaceutical products. Adrenaline is oxidized by triiodide ion immobilized in an anionic-exchange resin yielding adrenochrome which is transported by the carrier solution and detected at a wavelength of 488 nm. Adrenaline was determined in three pharmaceutical products in the 6.4 x 10-6 to 3.0 x 10-4 mol L-1 concentration range with a detection limit of 4.8 x 10-7 mol L-1. The recovery of this analyte in three samples ranged from 96.0 to 105 %. The analytical frequency was 80 determinations per hour and the RSDs were less than 1 % for adrenaline concentrations of 6.4 x 10-5 and 2.0 x 10-4 mol L-1 (n=10). A paired t-test showed that all results obtained for adrenaline in commercial formulations using the proposed flow injection procedure and a spectrophotometric batch procedure agree at the 95% confidence level.
publishDate 2004
dc.date.none.fl_str_mv 2004-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702004000100010
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702004000100010
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0100-46702004000100010
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP
publisher.none.fl_str_mv Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP
dc.source.none.fl_str_mv Eclética Química v.29 n.1 2004
reponame:Eclética Química
instname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Eclética Química
collection Eclética Química
repository.name.fl_str_mv Eclética Química - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
repository.mail.fl_str_mv ecletica@ctrlk.com.br||ecletica@iq.unesp.br
_version_ 1754734617669140480