Assesment of fixed and automated solar protection devices for residential building

Detalhes bibliográficos
Autor(a) principal: Leitzke, Rodrigo Karini
Data de Publicação: 2017
Outros Autores: Cunha, Eduardo Grala da, Silva, Oberdan Mendonça da, Silva, Antonio César Silveira Baptista da, Beltrame, Carolina Machado
Tipo de documento: Artigo
Idioma: por
Título da fonte: PARC (Campinas)
Texto Completo: https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8649657
Resumo: Solar protection systems play a significant role in the selective control of solar radiation in the interior space interfering, therefore, on the lighting, thermal and energy performance of buildings. This paper aims to conduct a comparative study of the performance of a solar protection system (fixed and automated mobile) of a building with a high level of thermal insulation using the Energy Management System (EMS) tool of the Energy Plus software. The methodological strategies proposed to involve the analysis of the configuration of eight different solar protection systems for the transparent closures, fixed brise-soleils, EMS implementation and, finally, analysis of the results of the simulations. The percentages of thermal comfort and electric energy consumption were evaluated considering the Brazilian bioclimatic zones 1 and 8. Among the cases tested, the model with external blinds automated by the EMS system at the windows presented the highest percentage of thermal comfort, and the lowest consumption of electric energy in the two analyzed Brazilian bioclimatic zones.
id UNICAMP-20_20ba13f40892ca0a2775ed2178a62bda
oai_identifier_str oai:ojs.periodicos.sbu.unicamp.br:article/8649657
network_acronym_str UNICAMP-20
network_name_str PARC (Campinas)
repository_id_str
spelling Assesment of fixed and automated solar protection devices for residential buildingAvaliação de dispositivos de proteção solar fixos e automatizados para edifício residencialProteção Solar. EMS. EnergyPlus. Simulação computacional.Solar protection. Energy Management System. Energy Plus. Computer Simulation.Solar protection systems play a significant role in the selective control of solar radiation in the interior space interfering, therefore, on the lighting, thermal and energy performance of buildings. This paper aims to conduct a comparative study of the performance of a solar protection system (fixed and automated mobile) of a building with a high level of thermal insulation using the Energy Management System (EMS) tool of the Energy Plus software. The methodological strategies proposed to involve the analysis of the configuration of eight different solar protection systems for the transparent closures, fixed brise-soleils, EMS implementation and, finally, analysis of the results of the simulations. The percentages of thermal comfort and electric energy consumption were evaluated considering the Brazilian bioclimatic zones 1 and 8. Among the cases tested, the model with external blinds automated by the EMS system at the windows presented the highest percentage of thermal comfort, and the lowest consumption of electric energy in the two analyzed Brazilian bioclimatic zones.Os sistemas de proteção solar cumprem um importante papel no controle seletivo de radiação solar no ambiente interior, interferindo, portanto, no desempenho luminoso, térmico e energético das edificações. Este artigo tem como objetivo realizar um estudo comparativo do desempenho de sistemas de proteção solar (fixos e móveis mecanizados) de uma edificação com elevado nível de isolamento térmico utilizando para isso a ferramenta Energy Management System (EMS) do software Energy Plus. As estratégias metodológicas propostas envolvem a análise da configuração de oito diferentes sistemas de proteção solar para os fechamentos transparentes, modelagem dos brise-soleils fixos, implementação do EMS para brise-soleis mecanizados e por fim, análise dos resultados das simulações realizadas. Foram avaliados os percentuais de conforto térmico e de consumo de energia elétrica considerando as zonas bioclimáticas brasileiras 1 e 8. Dentre os casos testados, o modelo com a utilização de persianas externas automatizadas pelo sistema EMS nos fechamentos transparentes apresentou os maiores percentuais de conforto térmico e o menor consumo de energia elétrica nas duas zonas bioclimáticas brasileiras analisadas.Universidade Estadual de Campinas2017-03-30info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionExperimental research. Simulation.Pesquisa experimental; Simulação computacionalapplication/pdfhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/864965710.20396/parc.v8i1.8649657PARC Pesquisa em Arquitetura e Construção; Vol. 8 No. 1 (2017); 59-72PARC Pesquisa em Arquitetura e Construção; Vol. 8 Núm. 1 (2017); 59-72PARC Pesquisa em Arquitetura e Construção; v. 8 n. 1 (2017); 59-721980-6809reponame:PARC (Campinas)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPporhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8649657/16691Copyright (c) 2018 PARC Pesquisa em Arquitetura e Construçãoinfo:eu-repo/semantics/openAccessLeitzke, Rodrigo KariniCunha, Eduardo Grala daSilva, Oberdan Mendonça daSilva, Antonio César Silveira Baptista daBeltrame, Carolina Machado2019-06-17T15:19:28Zoai:ojs.periodicos.sbu.unicamp.br:article/8649657Revistahttp://periodicos.sbu.unicamp.br/ojs/index.php/parcPUBhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/oai||parc@fec.unicamp.br1980-68091980-6809opendoar:2019-06-17T15:19:28PARC (Campinas) - Universidade Estadual de Campinas (UNICAMP)false
dc.title.none.fl_str_mv Assesment of fixed and automated solar protection devices for residential building
Avaliação de dispositivos de proteção solar fixos e automatizados para edifício residencial
title Assesment of fixed and automated solar protection devices for residential building
spellingShingle Assesment of fixed and automated solar protection devices for residential building
Leitzke, Rodrigo Karini
Proteção Solar. EMS. EnergyPlus. Simulação computacional.
Solar protection. Energy Management System. Energy Plus. Computer Simulation.
title_short Assesment of fixed and automated solar protection devices for residential building
title_full Assesment of fixed and automated solar protection devices for residential building
title_fullStr Assesment of fixed and automated solar protection devices for residential building
title_full_unstemmed Assesment of fixed and automated solar protection devices for residential building
title_sort Assesment of fixed and automated solar protection devices for residential building
author Leitzke, Rodrigo Karini
author_facet Leitzke, Rodrigo Karini
Cunha, Eduardo Grala da
Silva, Oberdan Mendonça da
Silva, Antonio César Silveira Baptista da
Beltrame, Carolina Machado
author_role author
author2 Cunha, Eduardo Grala da
Silva, Oberdan Mendonça da
Silva, Antonio César Silveira Baptista da
Beltrame, Carolina Machado
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Leitzke, Rodrigo Karini
Cunha, Eduardo Grala da
Silva, Oberdan Mendonça da
Silva, Antonio César Silveira Baptista da
Beltrame, Carolina Machado
dc.subject.por.fl_str_mv Proteção Solar. EMS. EnergyPlus. Simulação computacional.
Solar protection. Energy Management System. Energy Plus. Computer Simulation.
topic Proteção Solar. EMS. EnergyPlus. Simulação computacional.
Solar protection. Energy Management System. Energy Plus. Computer Simulation.
description Solar protection systems play a significant role in the selective control of solar radiation in the interior space interfering, therefore, on the lighting, thermal and energy performance of buildings. This paper aims to conduct a comparative study of the performance of a solar protection system (fixed and automated mobile) of a building with a high level of thermal insulation using the Energy Management System (EMS) tool of the Energy Plus software. The methodological strategies proposed to involve the analysis of the configuration of eight different solar protection systems for the transparent closures, fixed brise-soleils, EMS implementation and, finally, analysis of the results of the simulations. The percentages of thermal comfort and electric energy consumption were evaluated considering the Brazilian bioclimatic zones 1 and 8. Among the cases tested, the model with external blinds automated by the EMS system at the windows presented the highest percentage of thermal comfort, and the lowest consumption of electric energy in the two analyzed Brazilian bioclimatic zones.
publishDate 2017
dc.date.none.fl_str_mv 2017-03-30
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Experimental research. Simulation.
Pesquisa experimental; Simulação computacional
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8649657
10.20396/parc.v8i1.8649657
url https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8649657
identifier_str_mv 10.20396/parc.v8i1.8649657
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8649657/16691
dc.rights.driver.fl_str_mv Copyright (c) 2018 PARC Pesquisa em Arquitetura e Construção
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2018 PARC Pesquisa em Arquitetura e Construção
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Estadual de Campinas
publisher.none.fl_str_mv Universidade Estadual de Campinas
dc.source.none.fl_str_mv PARC Pesquisa em Arquitetura e Construção; Vol. 8 No. 1 (2017); 59-72
PARC Pesquisa em Arquitetura e Construção; Vol. 8 Núm. 1 (2017); 59-72
PARC Pesquisa em Arquitetura e Construção; v. 8 n. 1 (2017); 59-72
1980-6809
reponame:PARC (Campinas)
instname:Universidade Estadual de Campinas (UNICAMP)
instacron:UNICAMP
instname_str Universidade Estadual de Campinas (UNICAMP)
instacron_str UNICAMP
institution UNICAMP
reponame_str PARC (Campinas)
collection PARC (Campinas)
repository.name.fl_str_mv PARC (Campinas) - Universidade Estadual de Campinas (UNICAMP)
repository.mail.fl_str_mv ||parc@fec.unicamp.br
_version_ 1809283614361255936