Resumo: | Solar protection systems play a significant role in the selective control of solar radiation in the interior space interfering, therefore, on the lighting, thermal and energy performance of buildings. This paper aims to conduct a comparative study of the performance of a solar protection system (fixed and automated mobile) of a building with a high level of thermal insulation using the Energy Management System (EMS) tool of the Energy Plus software. The methodological strategies proposed to involve the analysis of the configuration of eight different solar protection systems for the transparent closures, fixed brise-soleils, EMS implementation and, finally, analysis of the results of the simulations. The percentages of thermal comfort and electric energy consumption were evaluated considering the Brazilian bioclimatic zones 1 and 8. Among the cases tested, the model with external blinds automated by the EMS system at the windows presented the highest percentage of thermal comfort, and the lowest consumption of electric energy in the two analyzed Brazilian bioclimatic zones. |
id |
UNICAMP-20_20ba13f40892ca0a2775ed2178a62bda |
---|---|
oai_identifier_str |
oai:ojs.periodicos.sbu.unicamp.br:article/8649657 |
network_acronym_str |
UNICAMP-20 |
network_name_str |
PARC (Campinas) |
repository_id_str |
|
spelling |
Assesment of fixed and automated solar protection devices for residential buildingAvaliação de dispositivos de proteção solar fixos e automatizados para edifício residencialProteção Solar. EMS. EnergyPlus. Simulação computacional.Solar protection. Energy Management System. Energy Plus. Computer Simulation.Solar protection systems play a significant role in the selective control of solar radiation in the interior space interfering, therefore, on the lighting, thermal and energy performance of buildings. This paper aims to conduct a comparative study of the performance of a solar protection system (fixed and automated mobile) of a building with a high level of thermal insulation using the Energy Management System (EMS) tool of the Energy Plus software. The methodological strategies proposed to involve the analysis of the configuration of eight different solar protection systems for the transparent closures, fixed brise-soleils, EMS implementation and, finally, analysis of the results of the simulations. The percentages of thermal comfort and electric energy consumption were evaluated considering the Brazilian bioclimatic zones 1 and 8. Among the cases tested, the model with external blinds automated by the EMS system at the windows presented the highest percentage of thermal comfort, and the lowest consumption of electric energy in the two analyzed Brazilian bioclimatic zones.Os sistemas de proteção solar cumprem um importante papel no controle seletivo de radiação solar no ambiente interior, interferindo, portanto, no desempenho luminoso, térmico e energético das edificações. Este artigo tem como objetivo realizar um estudo comparativo do desempenho de sistemas de proteção solar (fixos e móveis mecanizados) de uma edificação com elevado nível de isolamento térmico utilizando para isso a ferramenta Energy Management System (EMS) do software Energy Plus. As estratégias metodológicas propostas envolvem a análise da configuração de oito diferentes sistemas de proteção solar para os fechamentos transparentes, modelagem dos brise-soleils fixos, implementação do EMS para brise-soleis mecanizados e por fim, análise dos resultados das simulações realizadas. Foram avaliados os percentuais de conforto térmico e de consumo de energia elétrica considerando as zonas bioclimáticas brasileiras 1 e 8. Dentre os casos testados, o modelo com a utilização de persianas externas automatizadas pelo sistema EMS nos fechamentos transparentes apresentou os maiores percentuais de conforto térmico e o menor consumo de energia elétrica nas duas zonas bioclimáticas brasileiras analisadas.Universidade Estadual de Campinas2017-03-30info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionExperimental research. Simulation.Pesquisa experimental; Simulação computacionalapplication/pdfhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/864965710.20396/parc.v8i1.8649657PARC Pesquisa em Arquitetura e Construção; Vol. 8 No. 1 (2017); 59-72PARC Pesquisa em Arquitetura e Construção; Vol. 8 Núm. 1 (2017); 59-72PARC Pesquisa em Arquitetura e Construção; v. 8 n. 1 (2017); 59-721980-6809reponame:PARC (Campinas)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPporhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8649657/16691Copyright (c) 2018 PARC Pesquisa em Arquitetura e Construçãoinfo:eu-repo/semantics/openAccessLeitzke, Rodrigo KariniCunha, Eduardo Grala daSilva, Oberdan Mendonça daSilva, Antonio César Silveira Baptista daBeltrame, Carolina Machado2019-06-17T15:19:28Zoai:ojs.periodicos.sbu.unicamp.br:article/8649657Revistahttp://periodicos.sbu.unicamp.br/ojs/index.php/parcPUBhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/oai||parc@fec.unicamp.br1980-68091980-6809opendoar:2019-06-17T15:19:28PARC (Campinas) - Universidade Estadual de Campinas (UNICAMP)false |
dc.title.none.fl_str_mv |
Assesment of fixed and automated solar protection devices for residential building Avaliação de dispositivos de proteção solar fixos e automatizados para edifício residencial |
title |
Assesment of fixed and automated solar protection devices for residential building |
spellingShingle |
Assesment of fixed and automated solar protection devices for residential building Leitzke, Rodrigo Karini Proteção Solar. EMS. EnergyPlus. Simulação computacional. Solar protection. Energy Management System. Energy Plus. Computer Simulation. |
title_short |
Assesment of fixed and automated solar protection devices for residential building |
title_full |
Assesment of fixed and automated solar protection devices for residential building |
title_fullStr |
Assesment of fixed and automated solar protection devices for residential building |
title_full_unstemmed |
Assesment of fixed and automated solar protection devices for residential building |
title_sort |
Assesment of fixed and automated solar protection devices for residential building |
author |
Leitzke, Rodrigo Karini |
author_facet |
Leitzke, Rodrigo Karini Cunha, Eduardo Grala da Silva, Oberdan Mendonça da Silva, Antonio César Silveira Baptista da Beltrame, Carolina Machado |
author_role |
author |
author2 |
Cunha, Eduardo Grala da Silva, Oberdan Mendonça da Silva, Antonio César Silveira Baptista da Beltrame, Carolina Machado |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Leitzke, Rodrigo Karini Cunha, Eduardo Grala da Silva, Oberdan Mendonça da Silva, Antonio César Silveira Baptista da Beltrame, Carolina Machado |
dc.subject.por.fl_str_mv |
Proteção Solar. EMS. EnergyPlus. Simulação computacional. Solar protection. Energy Management System. Energy Plus. Computer Simulation. |
topic |
Proteção Solar. EMS. EnergyPlus. Simulação computacional. Solar protection. Energy Management System. Energy Plus. Computer Simulation. |
description |
Solar protection systems play a significant role in the selective control of solar radiation in the interior space interfering, therefore, on the lighting, thermal and energy performance of buildings. This paper aims to conduct a comparative study of the performance of a solar protection system (fixed and automated mobile) of a building with a high level of thermal insulation using the Energy Management System (EMS) tool of the Energy Plus software. The methodological strategies proposed to involve the analysis of the configuration of eight different solar protection systems for the transparent closures, fixed brise-soleils, EMS implementation and, finally, analysis of the results of the simulations. The percentages of thermal comfort and electric energy consumption were evaluated considering the Brazilian bioclimatic zones 1 and 8. Among the cases tested, the model with external blinds automated by the EMS system at the windows presented the highest percentage of thermal comfort, and the lowest consumption of electric energy in the two analyzed Brazilian bioclimatic zones. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-03-30 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Experimental research. Simulation. Pesquisa experimental; Simulação computacional |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8649657 10.20396/parc.v8i1.8649657 |
url |
https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8649657 |
identifier_str_mv |
10.20396/parc.v8i1.8649657 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8649657/16691 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2018 PARC Pesquisa em Arquitetura e Construção info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2018 PARC Pesquisa em Arquitetura e Construção |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Estadual de Campinas |
publisher.none.fl_str_mv |
Universidade Estadual de Campinas |
dc.source.none.fl_str_mv |
PARC Pesquisa em Arquitetura e Construção; Vol. 8 No. 1 (2017); 59-72 PARC Pesquisa em Arquitetura e Construção; Vol. 8 Núm. 1 (2017); 59-72 PARC Pesquisa em Arquitetura e Construção; v. 8 n. 1 (2017); 59-72 1980-6809 reponame:PARC (Campinas) instname:Universidade Estadual de Campinas (UNICAMP) instacron:UNICAMP |
instname_str |
Universidade Estadual de Campinas (UNICAMP) |
instacron_str |
UNICAMP |
institution |
UNICAMP |
reponame_str |
PARC (Campinas) |
collection |
PARC (Campinas) |
repository.name.fl_str_mv |
PARC (Campinas) - Universidade Estadual de Campinas (UNICAMP) |
repository.mail.fl_str_mv |
||parc@fec.unicamp.br |
_version_ |
1809283614361255936 |