Desempenho da mamotomia em alterações pre-neoplasicas e neoplasicas nas lesões não palpaveis da mama
Autor(a) principal: | |
---|---|
Data de Publicação: | 2005 |
Tipo de documento: | Tese |
Idioma: | por |
Título da fonte: | Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) |
Texto Completo: | https://hdl.handle.net/20.500.12733/1599474 |
Resumo: | Orientadores: Gustavo Antonio de Souza |
id |
UNICAMP-30_a8d51f85db573ea104fb780509d9a51b |
---|---|
oai_identifier_str |
oai::334629 |
network_acronym_str |
UNICAMP-30 |
network_name_str |
Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) |
repository_id_str |
|
spelling |
Desempenho da mamotomia em alterações pre-neoplasicas e neoplasicas nas lesões não palpaveis da mamaNeoplasias da mama - DiagnósticoMamas - Câncer - CirurgiaMamas - CirurgiaOrientadores: Gustavo Antonio de SouzaTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias MedicasResumo: Objetivo: Avaliar o desempenho diagnóstico da mamotomia em lesões neoplásicas ou pré-neoplásicas, não palpáveis da mama. Métodos: Durante o período de abril de 2000 a maio de 2004, cerca de 1100 mamotomias foram realizadas em clínica privada, sendo que 130 apresentaram diagnóstico de alteração maligna ou pré-maligna, indicativa de biópsia cirúrgica excisional terapêutica. Selecionaram-se então as pacientes com lesões mamárias não visibilizadas ao ultra-som, não palpáveis, com diâmetro até 20mm. Assim, 120 pacientes foram elegíveis ao estudo e as respectivas lâminas de biópsia cirúrgica excisional terapêutica. Todas as biópsias de mamotomia foram realizadas pelo mesmo cirurgião, em sistema de estereotaxia vertical, com a paciente sentada (Lorad® ¿ Danbury, CT), com acoplagem direta do sistema Mammotome® (Ethicon Endo-Surgery Biopsys ¿ Cincinnatti) sob anestesia local (xylocaína 2%) e utilizou-se cânula de 11 gauge. Todas as lâminas foram revisadas pelo mesmo patologista, no Laboratório de Anatomia Patológica da FCM/UNICAMP. O padrão-ouro foi considerado o resultado histológico de maior gravidade entre a mamotomia e a biópsia cirúrgica excisional terapêutica, designado como resultado histológico final. Realizou-se um estudo do tipo validação de teste diagnóstico. A análise estatística foi realizada através do cálculo da sensibilidade, especificidade, valores preditivos positivo (VPP) e negativo (VPN) da mamotomia. O mesmo tipo de análise foi realizado com relação às características mamográficas: padrão mamário, classificação BI-RADS, tipo de lesão e tamanho da mesma. A análise de concordância entre a mamotomia e a biópsia cirúrgica excisional terapêutica foi feita através do coeficiente Kappa. Resultados: A sensibilidade da mamotomia em identificar alterações pré-neoplásicas e neoplásicas no diagnóstico das lesões mamárias não palpáveis foi de 92,9% (IC 88,2 ¿ 97,5), com especificidade de 100% (IC 100¿100), VPP de 100% e VPN de 90,9%. Quando o padrão-ouro foi lesão pré-neoplásica, em todos os casos estudados das características mamográficas, encontrou-se teste 100% específico (IC 100-100), assim como o VPP. A sensibilidade da mamotomia em mamas densas foi de 81% (IC 64,2-97,7), VPN de 81% e eficácia de 89,5%. Para as mamas de padrão intermediário, a sensibilidade foi de 96,2% (IC 88,8-100), o VPN foi 94,1% e a eficácia foi 97,6%. Em mamas hipodensas a sensibilidade foi 100% (IC 100-100), o VPN de 100% e eficácia de 100%. Com relação à categoria de BI-RADS : em BI-RADS III ou IVA a sensibilidade foi 90% (IC 76,9-100), o VPN foi 94,1% e a eficácia foi de 96,2%. Em BI-RADS IVB : a sensibilidade foi 93,5% (IC84,9-100), o VPN foi 83,3% e a eficácia foi 95,1%. Em BI-RADS IVC : a sensibilidade foi 94,4% (IC 83,9-100), VPN foi 88,9% e a eficácia foi 96,2%. Em BI-RADS V, por ter somente um caso, não se realizou cálculos a respeito. Em relação ao tipo de lesão : em nódulo a sensibilidade foi 100% (IC100-100), o VPN foi 100% e a eficácia foi de 100%. Em relação à microcalcificação : a sensibilidade foi 85,7% (IC 72,8-98,7), o VPN foi 92% e a eficácia foi 94,6%. Nas assimetrias/ distorção focal arquitetural : a sensibilidade foi 96,8% (IC90,6-100), o VPN foi 50% e a eficácia 96,9%. Em relação ao tamanho da lesão : até 10mm a sensibilidade foi 100% (IC100-100), o VPN foi 100% e a eficácia foi 100%. De 10,1mm até 15mm : a sensibilidade foi 95,5% (IC 86,8-100), o VPN foi 96,2% e a eficácia foi 97,9%. De 15,1mm até 20mm : a sensibilidade foi 85,7% (IC 72,8-98,7), o VPN foi 60% e a eficácia foi 88,2%. A acurácia foi de 95,8% e a avaliação de concordância entre o resultado histológico da mamotomia e resultado histológico final apresentou coeficiente Kappa de 0,91 (IC 0,84-0,98). Conclusão: A mamotomia de lesões não palpáveis de mama guiada com sistema vertical de estereotaxia apresentou elevada acurácia, com sensibilidade de 92,9% e especificidade de 100% na população estudada. A concordância com o diagnóstico histológico final ocorreu em 0,91 com baixo percentual de subdiagnóstico (4,2%), corroborando sua aplicação como método seguro para biópsias de lesões mamográficas sem tradução clínica e sem correlação ecográficaAbstract: Objective: To evaluate the diagnostic performance of the mammotomy in malignant or pre-malignant, not concrete injuries of the breast. Methods: During the period from 2000 April to 2004 May, about 1100 mammotomies had been done in the private clinic, among that 130 presented malignant diagnostic or pre-malignant alteration, indicative of complementary excisional open biopsy. One selected then the patients with not visualized to the ultrasound, not concrete mammary injuries, with diameter until 20mm. Thus, 120 patients had been eligible to the study and the respective blades of therapeutical excisional surgical biopsy. All the biopsies of mammotomy had been carried through by the same surgeon, in system of vertical stereotaxy, with the seated patient (Lorad® - Danbury, CT), with direct fit of the Mammotome® system (Ethicon Endo-Surgery Biopsys - Cincinnatti) under local anesthesia (2% Xylocaine) and used 11 cannula of gauge. All the blades had been revised by the same patologist, in the Laboratory of Pathological Anatomy of FCM/UNICAMP. The standard gold was considered the histological result of bigger gravity between the mammotomy and the therapeutical excisional surgical biopsy, assigned as resulted histological end. A study of the type validation of diagnostic test was realized. The analysis statistics was carried through the calculation of sensitivity, specification, positive (VPP) and negative preditivo value (VPN) of the mammotomy. The same type of analysis was carried through with relation the mamography characteristics: mammary standard, BI-RADS classification, type of injury and size of the same one. The analysis of agreement between the mammotomy and the therapeutical excisional surgical biópsia was made through the Kappa coefficient. Results: The sensitivity of the mammotomy in identifying to alterations daily pay-neoplásicas and neoplásicas in the diagnosis of not concrete the mammary injuries was of 92,9% (IC 88,2 - 97,5), with specification of 100% (IC 100-100), VPP of 100% and VPN of 90,9%. When the standard gold was injury daily pay-neoplásica, in all the studied cases of the mammographic characteristics, met test 100% specific (IC 100-100), as well as the VPP. The sensitivity of the mammotomy in dense breasts was 81% (IC 64,2-97,7), VPN of 81% and effectiveness of 89,5%. For the breasts of intermediate standard, sensitivity was 96.2% (IC 88,8-100), the VPN was 94.1% and the effectiveness was 97,6%. In breasts hipodensas sensitivity was 100% (IC 100-100), the 100% effectiveness and VPN of 100%. With regard to category of BI-RADS: in BI-RADS III or IVA sensitivity was 90% (IC 76,9-100), the VPN was 94.1% and the effectiveness was of 96,2%. In BI-RADS IVB: sensitivity was 93.5% (IC 84,9-100), the VPN was 83.3% and the effectiveness was 95,1%. In BI-RADS IVC: sensitivity was 94.4% (IC 83,9-100), VPN was 88.9% and the effectiveness was 96,2%. In BI-RADS V for only having a case one did not become fullfilled calculations to the respect. In relation to the type of injury: in nodule sensitivity was 100% (IC100-100), the VPN was 100% and the effectiveness was of 100%. In relation the microcalcificacion: sensitivity was 85.7% (IC 72,8-98,7), the VPN was 92% and the effectiveness was 94,6%. In the focal asymmetry/architectural focal distortion: sensitivity was 96.8% (IC 90,6-100), the VPN was 50% and the effectiveness was 96,9%. In relation to the size of the injury: until 10mm sensitivity was 100% (IC100-100), the VPN was 100% and the effectiveness was 100%. Of 10,1mm until 15mm: sensitivity was 95.5% (IC 86,8-100), the VPN was 96.2% and the effectiveness was 97,9%. Of 15,1mm until 20mm: sensitivity was 85.7% (IC 72,8-98,7), the VPN was 60% and the effectiveness was 88,2%.A accuracy of 95,8% and the agreement evaluation enters the histological result of the mammotomy and the final histological diagnosis result presented Kappa coefficient of 0,91 (IC 0,84-0,98). Conclusion: The mammotomy of not concrete injuries of breast guided with vertical system of stereotaxy, presented high accuracy, with sensitivity of 92,9% and specification of 100% in the studied population. The agreement with the final histological diagnosis occurred in 0,91 with low percentage of diagnostic sub-estimation (4,2%), corroborating its application as safe method for breast injuries without clinical translation and ecographycal correlationDoutoradoTocoginecologiaDoutor em Tocoginecologia[s.n.]Souza, Gustavo Antonio de, 1941-Universidade Estadual de Campinas (UNICAMP). Faculdade de Ciências MédicasPrograma de Pós-Graduação não informadoUNIVERSIDADE ESTADUAL DE CAMPINASZambotti, Regina Paula20052005-02-17T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdf95f. : il.(Broch.)https://hdl.handle.net/20.500.12733/1599474ZAMBOTTI, Regina Paula. Desempenho da mamotomia em alterações pre-neoplasicas e neoplasicas nas lesões não palpaveis da mama. 2005. 95f. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas, Campinas, SP. Disponível em: https://hdl.handle.net/20.500.12733/1599474. Acesso em: 2 set. 2024.https://repositorio.unicamp.br/acervo/detalhe/334629porreponame:Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPinfo:eu-repo/semantics/openAccess2014-04-19T11:12:04Zoai::334629Biblioteca Digital de Teses e DissertaçõesPUBhttp://repositorio.unicamp.br/oai/tese/oai.aspsbubd@unicamp.bropendoar:2014-04-19T11:12:04Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) - Universidade Estadual de Campinas (UNICAMP)false |
dc.title.none.fl_str_mv |
Desempenho da mamotomia em alterações pre-neoplasicas e neoplasicas nas lesões não palpaveis da mama |
title |
Desempenho da mamotomia em alterações pre-neoplasicas e neoplasicas nas lesões não palpaveis da mama |
spellingShingle |
Desempenho da mamotomia em alterações pre-neoplasicas e neoplasicas nas lesões não palpaveis da mama Zambotti, Regina Paula Neoplasias da mama - Diagnóstico Mamas - Câncer - Cirurgia Mamas - Cirurgia |
title_short |
Desempenho da mamotomia em alterações pre-neoplasicas e neoplasicas nas lesões não palpaveis da mama |
title_full |
Desempenho da mamotomia em alterações pre-neoplasicas e neoplasicas nas lesões não palpaveis da mama |
title_fullStr |
Desempenho da mamotomia em alterações pre-neoplasicas e neoplasicas nas lesões não palpaveis da mama |
title_full_unstemmed |
Desempenho da mamotomia em alterações pre-neoplasicas e neoplasicas nas lesões não palpaveis da mama |
title_sort |
Desempenho da mamotomia em alterações pre-neoplasicas e neoplasicas nas lesões não palpaveis da mama |
author |
Zambotti, Regina Paula |
author_facet |
Zambotti, Regina Paula |
author_role |
author |
dc.contributor.none.fl_str_mv |
Souza, Gustavo Antonio de, 1941- Universidade Estadual de Campinas (UNICAMP). Faculdade de Ciências Médicas Programa de Pós-Graduação não informado UNIVERSIDADE ESTADUAL DE CAMPINAS |
dc.contributor.author.fl_str_mv |
Zambotti, Regina Paula |
dc.subject.por.fl_str_mv |
Neoplasias da mama - Diagnóstico Mamas - Câncer - Cirurgia Mamas - Cirurgia |
topic |
Neoplasias da mama - Diagnóstico Mamas - Câncer - Cirurgia Mamas - Cirurgia |
description |
Orientadores: Gustavo Antonio de Souza |
publishDate |
2005 |
dc.date.none.fl_str_mv |
2005 2005-02-17T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/doctoralThesis |
format |
doctoralThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
(Broch.) https://hdl.handle.net/20.500.12733/1599474 ZAMBOTTI, Regina Paula. Desempenho da mamotomia em alterações pre-neoplasicas e neoplasicas nas lesões não palpaveis da mama. 2005. 95f. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas, Campinas, SP. Disponível em: https://hdl.handle.net/20.500.12733/1599474. Acesso em: 2 set. 2024. |
identifier_str_mv |
(Broch.) ZAMBOTTI, Regina Paula. Desempenho da mamotomia em alterações pre-neoplasicas e neoplasicas nas lesões não palpaveis da mama. 2005. 95f. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas, Campinas, SP. Disponível em: https://hdl.handle.net/20.500.12733/1599474. Acesso em: 2 set. 2024. |
url |
https://hdl.handle.net/20.500.12733/1599474 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://repositorio.unicamp.br/acervo/detalhe/334629 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf 95f. : il. |
dc.publisher.none.fl_str_mv |
[s.n.] |
publisher.none.fl_str_mv |
[s.n.] |
dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) instname:Universidade Estadual de Campinas (UNICAMP) instacron:UNICAMP |
instname_str |
Universidade Estadual de Campinas (UNICAMP) |
instacron_str |
UNICAMP |
institution |
UNICAMP |
reponame_str |
Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) |
collection |
Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) |
repository.name.fl_str_mv |
Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) - Universidade Estadual de Campinas (UNICAMP) |
repository.mail.fl_str_mv |
sbubd@unicamp.br |
_version_ |
1809188919462330368 |