Resumo: | Aim: The aim of this study was to evaluate fracture toughness by indentation method of three dental ceramics processed by heat pressing. The ceramics evaluated were fluorapatite glass ceramic (ZIR), glass ceramic containing leucite (POM) and leucite-reinforced glass ceramic (EMP). Materials and methods: Ninety disks (13mm of diameter x 4mm of thickness) and nine rectangular specimens (25x4x2mm) were made to evaluate, respectively, microhardness/fracture toughness (n=30) and elastic modulus (n=3). Samples were obtained by pressing ceramic into refractory molds. After polishing, Vickers microhardness was evaluated under 4,904N load for 20s. Elastic modulus was measured by impulse excitation technique. Data from microhardness and elastic modulus were used to calculate fracture toughness, after measuring crack length under 19,6N load applied for 20s. Results were evaluated by ANOVA and Tukey´s test. Results: Microhardness (VHN) of POM (637.9±53.6) was statistically greater (p<0.05) than ZIR (593.0±14.3), followed by EMP (519.1±21.5); no significant difference (p=0.206) was noted for elastic modulus (GPa) (ZIR: 71.5±9.0; POM: 67.3±4.4; EMP: 61.7±2.3). Fracture toughness (MPa/m) of POM (0.873±0.066) was statistically lower (p<0.05) than ZIR (0.977±0.021) and EMP (0.965±0.035). Conclusion: The results suggest that fluorapatite glass ceramic (ZIR) and leucite-reinforced glass ceramic (EMP) processed by heat pressing presented greater fracture toughness, improving clinical prognosis of metal free restorations. |
id |
UNICAMP-8_1746d27449323b27dbfb84e647a2a944 |
---|---|
oai_identifier_str |
oai:ojs.periodicos.sbu.unicamp.br:article/8651897 |
network_acronym_str |
UNICAMP-8 |
network_name_str |
Brazilian journal of oral sciences (Online) |
repository_id_str |
|
spelling |
Fracture toughness of three heat pressed ceramic systemsDental porcelain. Hardness tests. Elastic modulus.Aim: The aim of this study was to evaluate fracture toughness by indentation method of three dental ceramics processed by heat pressing. The ceramics evaluated were fluorapatite glass ceramic (ZIR), glass ceramic containing leucite (POM) and leucite-reinforced glass ceramic (EMP). Materials and methods: Ninety disks (13mm of diameter x 4mm of thickness) and nine rectangular specimens (25x4x2mm) were made to evaluate, respectively, microhardness/fracture toughness (n=30) and elastic modulus (n=3). Samples were obtained by pressing ceramic into refractory molds. After polishing, Vickers microhardness was evaluated under 4,904N load for 20s. Elastic modulus was measured by impulse excitation technique. Data from microhardness and elastic modulus were used to calculate fracture toughness, after measuring crack length under 19,6N load applied for 20s. Results were evaluated by ANOVA and Tukey´s test. Results: Microhardness (VHN) of POM (637.9±53.6) was statistically greater (p<0.05) than ZIR (593.0±14.3), followed by EMP (519.1±21.5); no significant difference (p=0.206) was noted for elastic modulus (GPa) (ZIR: 71.5±9.0; POM: 67.3±4.4; EMP: 61.7±2.3). Fracture toughness (MPa/m) of POM (0.873±0.066) was statistically lower (p<0.05) than ZIR (0.977±0.021) and EMP (0.965±0.035). Conclusion: The results suggest that fluorapatite glass ceramic (ZIR) and leucite-reinforced glass ceramic (EMP) processed by heat pressing presented greater fracture toughness, improving clinical prognosis of metal free restorations.Universidade Estadual de Campinas2018-04-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionOriginal articleapplication/pdfhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/865189710.20396/bjos.v17i0.8651897Brazilian Journal of Oral Sciences; v. 17 (2018): Continuous Publication; e18017Brazilian Journal of Oral Sciences; Vol. 17 (2018): Continuous Publication; e180171677-3225reponame:Brazilian journal of oral sciences (Online)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPenghttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8651897/18013Fiorin, LiviaTheodoro, Guilherme TeixeiraMoris, Izabela Cristina MaurícioRodrigues, Renata Cristina SilveiraRibeiro, Ricardo FariaFaria, Adriana Cláudia Lapriainfo:eu-repo/semantics/openAccess2020-12-22T01:34:08Zoai:ojs.periodicos.sbu.unicamp.br:article/8651897Revistahttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/PUBhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/oaibrjorals@fop.unicamp.br||brjorals@fop.unicamp.br1677-32251677-3217opendoar:2020-12-22T01:34:08Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP)false |
dc.title.none.fl_str_mv |
Fracture toughness of three heat pressed ceramic systems |
title |
Fracture toughness of three heat pressed ceramic systems |
spellingShingle |
Fracture toughness of three heat pressed ceramic systems Fiorin, Livia Dental porcelain. Hardness tests. Elastic modulus. |
title_short |
Fracture toughness of three heat pressed ceramic systems |
title_full |
Fracture toughness of three heat pressed ceramic systems |
title_fullStr |
Fracture toughness of three heat pressed ceramic systems |
title_full_unstemmed |
Fracture toughness of three heat pressed ceramic systems |
title_sort |
Fracture toughness of three heat pressed ceramic systems |
author |
Fiorin, Livia |
author_facet |
Fiorin, Livia Theodoro, Guilherme Teixeira Moris, Izabela Cristina Maurício Rodrigues, Renata Cristina Silveira Ribeiro, Ricardo Faria Faria, Adriana Cláudia Lapria |
author_role |
author |
author2 |
Theodoro, Guilherme Teixeira Moris, Izabela Cristina Maurício Rodrigues, Renata Cristina Silveira Ribeiro, Ricardo Faria Faria, Adriana Cláudia Lapria |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Fiorin, Livia Theodoro, Guilherme Teixeira Moris, Izabela Cristina Maurício Rodrigues, Renata Cristina Silveira Ribeiro, Ricardo Faria Faria, Adriana Cláudia Lapria |
dc.subject.por.fl_str_mv |
Dental porcelain. Hardness tests. Elastic modulus. |
topic |
Dental porcelain. Hardness tests. Elastic modulus. |
description |
Aim: The aim of this study was to evaluate fracture toughness by indentation method of three dental ceramics processed by heat pressing. The ceramics evaluated were fluorapatite glass ceramic (ZIR), glass ceramic containing leucite (POM) and leucite-reinforced glass ceramic (EMP). Materials and methods: Ninety disks (13mm of diameter x 4mm of thickness) and nine rectangular specimens (25x4x2mm) were made to evaluate, respectively, microhardness/fracture toughness (n=30) and elastic modulus (n=3). Samples were obtained by pressing ceramic into refractory molds. After polishing, Vickers microhardness was evaluated under 4,904N load for 20s. Elastic modulus was measured by impulse excitation technique. Data from microhardness and elastic modulus were used to calculate fracture toughness, after measuring crack length under 19,6N load applied for 20s. Results were evaluated by ANOVA and Tukey´s test. Results: Microhardness (VHN) of POM (637.9±53.6) was statistically greater (p<0.05) than ZIR (593.0±14.3), followed by EMP (519.1±21.5); no significant difference (p=0.206) was noted for elastic modulus (GPa) (ZIR: 71.5±9.0; POM: 67.3±4.4; EMP: 61.7±2.3). Fracture toughness (MPa/m) of POM (0.873±0.066) was statistically lower (p<0.05) than ZIR (0.977±0.021) and EMP (0.965±0.035). Conclusion: The results suggest that fluorapatite glass ceramic (ZIR) and leucite-reinforced glass ceramic (EMP) processed by heat pressing presented greater fracture toughness, improving clinical prognosis of metal free restorations. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-04-03 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Original article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8651897 10.20396/bjos.v17i0.8651897 |
url |
https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8651897 |
identifier_str_mv |
10.20396/bjos.v17i0.8651897 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8651897/18013 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Estadual de Campinas |
publisher.none.fl_str_mv |
Universidade Estadual de Campinas |
dc.source.none.fl_str_mv |
Brazilian Journal of Oral Sciences; v. 17 (2018): Continuous Publication; e18017 Brazilian Journal of Oral Sciences; Vol. 17 (2018): Continuous Publication; e18017 1677-3225 reponame:Brazilian journal of oral sciences (Online) instname:Universidade Estadual de Campinas (UNICAMP) instacron:UNICAMP |
instname_str |
Universidade Estadual de Campinas (UNICAMP) |
instacron_str |
UNICAMP |
institution |
UNICAMP |
reponame_str |
Brazilian journal of oral sciences (Online) |
collection |
Brazilian journal of oral sciences (Online) |
repository.name.fl_str_mv |
Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP) |
repository.mail.fl_str_mv |
brjorals@fop.unicamp.br||brjorals@fop.unicamp.br |
_version_ |
1800216402241519616 |