Effect of chemical denture cleansers on flexural resistance and color changes of microwave-polymerized acrylic resins
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian journal of oral sciences (Online) |
Texto Completo: | https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8642798 |
Resumo: | Aim: The aim of this study was to assess the flexural resistance and color alterations of microwave-polymerized acrylic resins immersed in denture cleansers for different periods of time. Methods: Forty-five rectangular specimens (65x10x3mm) of each commercial brand of the microwave-activated acrylic resins (Vipi Wave and Onda Cryl) were divided in three denture cleanser groups (Bony Plus, Corega Tabs and Efferdent Plus) and a control group (immersion in water). Soaking trials of 15 min and 8 h simulated 30 days of use. The flexural strength test was carried out in a universal testing machine. Color alterations were assessed by visual inspection of photographs. The results obtained in the flexural test, in kgf, were converted to MPa and these values were submitted to analysis of variance with a 5% significance level. Results: There were no significant differences (p<0.05) between Onda Cryl (85.61±12.76) and Vipi Wave (89.8±19.95) after the soaking trials regarding the use of different denture cleansers. No differences were found in relation to the solutions [Bony Plus (88.52±9.89), Corega Tabs (88.75±12.71) and Efferdent (85.86±12.11)], soaking periods [control (87.17±12.92), 15 min (88.05±11.74) and 8 h (87.91±10.30)], and interactions during the 30 days of simulated use. Visual inspection did not detect any color alterations. Conclusions: Denture cleansers, when used according to the manufacturers’ instructions, did not cause any mechanical or visual alterations in the microwave-polymerized acrylic resins after a simulated period of 30 days of use. |
id |
UNICAMP-8_4076bab4aed785ac9e51844197a8a51f |
---|---|
oai_identifier_str |
oai:ojs.periodicos.sbu.unicamp.br:article/8642798 |
network_acronym_str |
UNICAMP-8 |
network_name_str |
Brazilian journal of oral sciences (Online) |
repository_id_str |
|
spelling |
Effect of chemical denture cleansers on flexural resistance and color changes of microwave-polymerized acrylic resinsComplete denturesAcrylic resinMicrowaveDenture cleansersFlexion resistanceColorOdontologyAim: The aim of this study was to assess the flexural resistance and color alterations of microwave-polymerized acrylic resins immersed in denture cleansers for different periods of time. Methods: Forty-five rectangular specimens (65x10x3mm) of each commercial brand of the microwave-activated acrylic resins (Vipi Wave and Onda Cryl) were divided in three denture cleanser groups (Bony Plus, Corega Tabs and Efferdent Plus) and a control group (immersion in water). Soaking trials of 15 min and 8 h simulated 30 days of use. The flexural strength test was carried out in a universal testing machine. Color alterations were assessed by visual inspection of photographs. The results obtained in the flexural test, in kgf, were converted to MPa and these values were submitted to analysis of variance with a 5% significance level. Results: There were no significant differences (p<0.05) between Onda Cryl (85.61±12.76) and Vipi Wave (89.8±19.95) after the soaking trials regarding the use of different denture cleansers. No differences were found in relation to the solutions [Bony Plus (88.52±9.89), Corega Tabs (88.75±12.71) and Efferdent (85.86±12.11)], soaking periods [control (87.17±12.92), 15 min (88.05±11.74) and 8 h (87.91±10.30)], and interactions during the 30 days of simulated use. Visual inspection did not detect any color alterations. Conclusions: Denture cleansers, when used according to the manufacturers’ instructions, did not cause any mechanical or visual alterations in the microwave-polymerized acrylic resins after a simulated period of 30 days of use.Universidade Estadual de Campinas2008-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/864279810.20396/bjos.v7i26.8642798Brazilian Journal of Oral Sciences; v. 7 n. 26 (2008): Jul./Sep.; 1580-1584Brazilian Journal of Oral Sciences; Vol. 7 No. 26 (2008): Jul./Sep.; 1580-15841677-3225reponame:Brazilian journal of oral sciences (Online)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPenghttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8642798/10351Paranhos, Helena de Freitas OliveiraOrsi, Iara AugustaZaniquelli, OsvaldoZuccolotto, Maria Cristina CandelasMagalhães, Fabrícioinfo:eu-repo/semantics/openAccess2016-02-25T09:25:15Zoai:ojs.periodicos.sbu.unicamp.br:article/8642798Revistahttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/PUBhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/oaibrjorals@fop.unicamp.br||brjorals@fop.unicamp.br1677-32251677-3217opendoar:2016-02-25T09:25:15Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP)false |
dc.title.none.fl_str_mv |
Effect of chemical denture cleansers on flexural resistance and color changes of microwave-polymerized acrylic resins |
title |
Effect of chemical denture cleansers on flexural resistance and color changes of microwave-polymerized acrylic resins |
spellingShingle |
Effect of chemical denture cleansers on flexural resistance and color changes of microwave-polymerized acrylic resins Paranhos, Helena de Freitas Oliveira Complete dentures Acrylic resin Microwave Denture cleansers Flexion resistance Color Odontology |
title_short |
Effect of chemical denture cleansers on flexural resistance and color changes of microwave-polymerized acrylic resins |
title_full |
Effect of chemical denture cleansers on flexural resistance and color changes of microwave-polymerized acrylic resins |
title_fullStr |
Effect of chemical denture cleansers on flexural resistance and color changes of microwave-polymerized acrylic resins |
title_full_unstemmed |
Effect of chemical denture cleansers on flexural resistance and color changes of microwave-polymerized acrylic resins |
title_sort |
Effect of chemical denture cleansers on flexural resistance and color changes of microwave-polymerized acrylic resins |
author |
Paranhos, Helena de Freitas Oliveira |
author_facet |
Paranhos, Helena de Freitas Oliveira Orsi, Iara Augusta Zaniquelli, Osvaldo Zuccolotto, Maria Cristina Candelas Magalhães, Fabrício |
author_role |
author |
author2 |
Orsi, Iara Augusta Zaniquelli, Osvaldo Zuccolotto, Maria Cristina Candelas Magalhães, Fabrício |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Paranhos, Helena de Freitas Oliveira Orsi, Iara Augusta Zaniquelli, Osvaldo Zuccolotto, Maria Cristina Candelas Magalhães, Fabrício |
dc.subject.por.fl_str_mv |
Complete dentures Acrylic resin Microwave Denture cleansers Flexion resistance Color Odontology |
topic |
Complete dentures Acrylic resin Microwave Denture cleansers Flexion resistance Color Odontology |
description |
Aim: The aim of this study was to assess the flexural resistance and color alterations of microwave-polymerized acrylic resins immersed in denture cleansers for different periods of time. Methods: Forty-five rectangular specimens (65x10x3mm) of each commercial brand of the microwave-activated acrylic resins (Vipi Wave and Onda Cryl) were divided in three denture cleanser groups (Bony Plus, Corega Tabs and Efferdent Plus) and a control group (immersion in water). Soaking trials of 15 min and 8 h simulated 30 days of use. The flexural strength test was carried out in a universal testing machine. Color alterations were assessed by visual inspection of photographs. The results obtained in the flexural test, in kgf, were converted to MPa and these values were submitted to analysis of variance with a 5% significance level. Results: There were no significant differences (p<0.05) between Onda Cryl (85.61±12.76) and Vipi Wave (89.8±19.95) after the soaking trials regarding the use of different denture cleansers. No differences were found in relation to the solutions [Bony Plus (88.52±9.89), Corega Tabs (88.75±12.71) and Efferdent (85.86±12.11)], soaking periods [control (87.17±12.92), 15 min (88.05±11.74) and 8 h (87.91±10.30)], and interactions during the 30 days of simulated use. Visual inspection did not detect any color alterations. Conclusions: Denture cleansers, when used according to the manufacturers’ instructions, did not cause any mechanical or visual alterations in the microwave-polymerized acrylic resins after a simulated period of 30 days of use. |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8642798 10.20396/bjos.v7i26.8642798 |
url |
https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8642798 |
identifier_str_mv |
10.20396/bjos.v7i26.8642798 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8642798/10351 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Estadual de Campinas |
publisher.none.fl_str_mv |
Universidade Estadual de Campinas |
dc.source.none.fl_str_mv |
Brazilian Journal of Oral Sciences; v. 7 n. 26 (2008): Jul./Sep.; 1580-1584 Brazilian Journal of Oral Sciences; Vol. 7 No. 26 (2008): Jul./Sep.; 1580-1584 1677-3225 reponame:Brazilian journal of oral sciences (Online) instname:Universidade Estadual de Campinas (UNICAMP) instacron:UNICAMP |
instname_str |
Universidade Estadual de Campinas (UNICAMP) |
instacron_str |
UNICAMP |
institution |
UNICAMP |
reponame_str |
Brazilian journal of oral sciences (Online) |
collection |
Brazilian journal of oral sciences (Online) |
repository.name.fl_str_mv |
Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP) |
repository.mail.fl_str_mv |
brjorals@fop.unicamp.br||brjorals@fop.unicamp.br |
_version_ |
1800216401090183168 |