Feasibility of implementing water reuse system of air conditioners: case study in the main building of Christus Faculdade do Piauí

Detalhes bibliográficos
Autor(a) principal: Oliveira, Anderson Gabriel Martins De
Data de Publicação: 2021
Outros Autores: Alves, Linda Jéssica Sotero, Araújo, Ian Carlos Andrade, Silva, Mayrã do Nascimento, Meneses, Mariana Melo, Pires, Camilla de Jesús, Carvalho, Tamires Almeida, Melo, Ana Raquel da Silva, Honorato, Paula Eduarda Oliveira, Lima, Lidiane da Costa Reis
Tipo de documento: Artigo
Idioma: por
Título da fonte: Research, Society and Development
Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/19510
Resumo: This article aims to analyze the feasibility of water reuse in the use of air conditioners used at Christus Faculdade do Piauí, CHRISFAPI, in Piripiri-PI, as a set of actual case studies, based on data collections made in the dripping of the drains of the apparatus of the aforementioned faculty. With reuse, impacts resulting from inappropriate disposal of water will be visibly commuted. The air conditioners have particularities according to the brand, among them: temperature, energy consumption and Btus (British Thermalunits Thermal Unit). 99 ceiling floor type air conditioners have been listed, with a capacity of 2200 Btus, of two distinct brands, Carrier e Spring, installed in 43 classrooms. For the collection of discarded water, two basins were used, one for each type in an interval of one hour. After collection, with the aid of a beaker, the exact volume of water wasted during the period mentioned above has been measured, and reproduced to the remaining machines, reaching a total of 718.36 liters of water per school day. The results obtained show a viable alternative for the storage and reuse of water that would be wasted. Therefore, this article brought to the institution not only information on the quantity of water that can be reused in the Faculty itself, but only the benefits to come for other purposes within the institution.
id UNIFEI_0c35d915783ad7de86b32c8e32b94ffa
oai_identifier_str oai:ojs.pkp.sfu.ca:article/19510
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Feasibility of implementing water reuse system of air conditioners: case study in the main building of Christus Faculdade do PiauíFactibilidad de la implementación del sistema de reutilización de agua de aires acondicionados: estudio de caso en el edificio principal de la Christus Faculdade do PiauíViabilidade de implantação de sistema de reaproveitamento de água de aparelhos de ares-condicionados: estudo de caso no prédio principal da Christus Faculdade do PiauíReusoAr-condicionadoGotejamentoColetaConsumo.ReutilizaciónAire acondicionadoGoteoColecciónConsumo.ReuseAir conditioningDripCollectionConsumption.This article aims to analyze the feasibility of water reuse in the use of air conditioners used at Christus Faculdade do Piauí, CHRISFAPI, in Piripiri-PI, as a set of actual case studies, based on data collections made in the dripping of the drains of the apparatus of the aforementioned faculty. With reuse, impacts resulting from inappropriate disposal of water will be visibly commuted. The air conditioners have particularities according to the brand, among them: temperature, energy consumption and Btus (British Thermalunits Thermal Unit). 99 ceiling floor type air conditioners have been listed, with a capacity of 2200 Btus, of two distinct brands, Carrier e Spring, installed in 43 classrooms. For the collection of discarded water, two basins were used, one for each type in an interval of one hour. After collection, with the aid of a beaker, the exact volume of water wasted during the period mentioned above has been measured, and reproduced to the remaining machines, reaching a total of 718.36 liters of water per school day. The results obtained show a viable alternative for the storage and reuse of water that would be wasted. Therefore, this article brought to the institution not only information on the quantity of water that can be reused in the Faculty itself, but only the benefits to come for other purposes within the institution.Este artículo tiene como objetivo analizar la viabilidad de la reutilización de agua en el uso de acondicionadores de aire utilizados en Christus Faculdade do Piauí, CHRISFAPI, en Piripiri-PI, como un conjunto de estudios de casos reales, basados ​​en la recolección de datos realizados en el goteo de los desagües de el aparato de la mencionada facultad. Con la reutilización, los impactos resultantes de la eliminación inadecuada del agua se conmutarán visiblemente. Los aires acondicionados tienen particularidades según la marca, entre ellas: temperatura, consumo energético y Btus (Unidad Térmica Británica de Unidades Térmicas). Se han listado 99 aires acondicionados tipo techo y piso, con una capacidad de 2200 Btus, de dos marcas distintas, Carrier e Spring, instalados en 43 aulas. Para la recolección de agua descartada se utilizaron dos tinas, una para cada tipo en un intervalo de una hora. Tras la recogida, con la ayuda de un vaso de precipitados, se ha medido el volumen exacto de agua desperdiciada durante el período mencionado anteriormente y se ha reproducido al resto de máquinas, alcanzando un total de 718,36 litros de agua por jornada escolar. Los resultados obtenidos muestran una alternativa viable para el almacenamiento y reutilización del agua que se desperdiciaría. Por lo tanto, este artículo trajo a la institución no solo información sobre la cantidad de agua que se puede reutilizar en la propia Facultad, sino solo los beneficios por venir para otros fines dentro de la institución.O presente artigo tem por objetivo analisar a viabilidade do reaproveitamento de água no uso de aparelhos ares-condicionados usados na Christus Faculdade do Piauí, CHRISFAPI, em Piripiri-PI, em conjunto de estudo de caso real, baseado em coletas de dados feitos no gotejamento dos drenos dos aparelhos da mencionada faculdade. Com reaproveitamento, impactos decorrentes de descarte inapropriado da água serão visivelmente atenuados. Os aparelhos de ares-condicionados detêm de particularidades conforme a marca, dentre elas: temperatura, consumo de energia e BTUs (British ThermalUnits Unidade Térmica Britânica). Foram enumerados 99 aparelhos de ares-condicionados do tipo piso teto, com capacidade de 2200 BTUs, sendo esses de duas marcas distintas, Carrier e Spring, instalados em 43 salas de aula. Para a colheita de água descartada, foram utilizadas duas bacias, uma para cada tipo de aparelho, em um intervalo de uma hora. Após a coleta, com auxílio de uma proveta, foi mensurado exatamente o volume de água desperdiçado, durante o período já mencionado, e reproduzido às máquinas restantes, chegando a um total de 718,36 litros de água por dia letivo. Os resultados obtidos mostram uma alternativa viável para o armazenamento e reuso da água que seria desperdiçada. Por conseguinte, este artigo trouxe para instituição não só a informação da quantidade de água que pode ser reutilizada na própria Faculdade, mas tão somente os benefícios vindouros de destinação para outros fins no âmbito da instituição.Research, Society and Development2021-08-29info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/1951010.33448/rsd-v10i11.19510Research, Society and Development; Vol. 10 No. 11; e203101119510Research, Society and Development; Vol. 10 Núm. 11; e203101119510Research, Society and Development; v. 10 n. 11; e2031011195102525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIporhttps://rsdjournal.org/index.php/rsd/article/view/19510/17479Copyright (c) 2021 Anderson Gabriel Martins De Oliveira; Linda Jéssica Sotero Alves; Ian Carlos Andrade Araújo; Mayrã do Nascimento Silva; Mariana Melo Meneses; Camilla de Jesús Pires; Tamires Almeida Carvalho; Ana Raquel da Silva Melo; Paula Eduarda Oliveira Honorato; Lidiane da Costa Reis Limahttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccess Oliveira, Anderson Gabriel Martins De Alves, Linda Jéssica Sotero Araújo, Ian Carlos Andrade Silva, Mayrã do NascimentoMeneses, Mariana Melo Pires, Camilla de JesúsCarvalho, Tamires Almeida Melo, Ana Raquel da Silva Honorato, Paula Eduarda Oliveira Lima, Lidiane da Costa Reis2021-10-23T19:01:11Zoai:ojs.pkp.sfu.ca:article/19510Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:39:23.194082Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Feasibility of implementing water reuse system of air conditioners: case study in the main building of Christus Faculdade do Piauí
Factibilidad de la implementación del sistema de reutilización de agua de aires acondicionados: estudio de caso en el edificio principal de la Christus Faculdade do Piauí
Viabilidade de implantação de sistema de reaproveitamento de água de aparelhos de ares-condicionados: estudo de caso no prédio principal da Christus Faculdade do Piauí
title Feasibility of implementing water reuse system of air conditioners: case study in the main building of Christus Faculdade do Piauí
spellingShingle Feasibility of implementing water reuse system of air conditioners: case study in the main building of Christus Faculdade do Piauí
Oliveira, Anderson Gabriel Martins De
Reuso
Ar-condicionado
Gotejamento
Coleta
Consumo.
Reutilización
Aire acondicionado
Goteo
Colección
Consumo.
Reuse
Air conditioning
Drip
Collection
Consumption.
title_short Feasibility of implementing water reuse system of air conditioners: case study in the main building of Christus Faculdade do Piauí
title_full Feasibility of implementing water reuse system of air conditioners: case study in the main building of Christus Faculdade do Piauí
title_fullStr Feasibility of implementing water reuse system of air conditioners: case study in the main building of Christus Faculdade do Piauí
title_full_unstemmed Feasibility of implementing water reuse system of air conditioners: case study in the main building of Christus Faculdade do Piauí
title_sort Feasibility of implementing water reuse system of air conditioners: case study in the main building of Christus Faculdade do Piauí
author Oliveira, Anderson Gabriel Martins De
author_facet Oliveira, Anderson Gabriel Martins De
Alves, Linda Jéssica Sotero
Araújo, Ian Carlos Andrade
Silva, Mayrã do Nascimento
Meneses, Mariana Melo
Pires, Camilla de Jesús
Carvalho, Tamires Almeida
Melo, Ana Raquel da Silva
Honorato, Paula Eduarda Oliveira
Lima, Lidiane da Costa Reis
author_role author
author2 Alves, Linda Jéssica Sotero
Araújo, Ian Carlos Andrade
Silva, Mayrã do Nascimento
Meneses, Mariana Melo
Pires, Camilla de Jesús
Carvalho, Tamires Almeida
Melo, Ana Raquel da Silva
Honorato, Paula Eduarda Oliveira
Lima, Lidiane da Costa Reis
author2_role author
author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Oliveira, Anderson Gabriel Martins De
Alves, Linda Jéssica Sotero
Araújo, Ian Carlos Andrade
Silva, Mayrã do Nascimento
Meneses, Mariana Melo
Pires, Camilla de Jesús
Carvalho, Tamires Almeida
Melo, Ana Raquel da Silva
Honorato, Paula Eduarda Oliveira
Lima, Lidiane da Costa Reis
dc.subject.por.fl_str_mv Reuso
Ar-condicionado
Gotejamento
Coleta
Consumo.
Reutilización
Aire acondicionado
Goteo
Colección
Consumo.
Reuse
Air conditioning
Drip
Collection
Consumption.
topic Reuso
Ar-condicionado
Gotejamento
Coleta
Consumo.
Reutilización
Aire acondicionado
Goteo
Colección
Consumo.
Reuse
Air conditioning
Drip
Collection
Consumption.
description This article aims to analyze the feasibility of water reuse in the use of air conditioners used at Christus Faculdade do Piauí, CHRISFAPI, in Piripiri-PI, as a set of actual case studies, based on data collections made in the dripping of the drains of the apparatus of the aforementioned faculty. With reuse, impacts resulting from inappropriate disposal of water will be visibly commuted. The air conditioners have particularities according to the brand, among them: temperature, energy consumption and Btus (British Thermalunits Thermal Unit). 99 ceiling floor type air conditioners have been listed, with a capacity of 2200 Btus, of two distinct brands, Carrier e Spring, installed in 43 classrooms. For the collection of discarded water, two basins were used, one for each type in an interval of one hour. After collection, with the aid of a beaker, the exact volume of water wasted during the period mentioned above has been measured, and reproduced to the remaining machines, reaching a total of 718.36 liters of water per school day. The results obtained show a viable alternative for the storage and reuse of water that would be wasted. Therefore, this article brought to the institution not only information on the quantity of water that can be reused in the Faculty itself, but only the benefits to come for other purposes within the institution.
publishDate 2021
dc.date.none.fl_str_mv 2021-08-29
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/19510
10.33448/rsd-v10i11.19510
url https://rsdjournal.org/index.php/rsd/article/view/19510
identifier_str_mv 10.33448/rsd-v10i11.19510
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/19510/17479
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 10 No. 11; e203101119510
Research, Society and Development; Vol. 10 Núm. 11; e203101119510
Research, Society and Development; v. 10 n. 11; e203101119510
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052788441612288