Resumo: Coffin edifices buildings that commonly use resistant masonry as structural, without being based on recognized standards. This style of building began to be widespread in the 1970s in the Metropolitan Region of Recife due to the reduction of time and cost. From the 1990s, accidents in coffin buildings began to occur, along with a series of notifications of building defects. In order to map and carry out interdictions, in the necessary cases, several building inspection reports were carried out, either by determination of the Public Power or by initiative of the owners themselves. Five of these reports were selected for the present research, whose objective is to study the main defects of coffin buildings in three elements: foundation, superstructure and façade. To this end, the GUT Matrix was applied to determine the severity and resolution priority of the observed problems. After the analyses, it was shown that the damages present in the foundation and in the superstructure have priority in the resolution.
id UNIFEI_1d999ff9a8d68c2ad65cd787d1403177
oai_identifier_str oai:ojs.pkp.sfu.ca:article/32219
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Box type buildings: use of GUT Matrix in the analysis of defects of five buildings in Recife-PE and metropolitan regionEdificios tipo ataúd: uso de GUT Matrix en el análisis de manifestaciones patológicas de cinco edificios en Recife-PE y región metropolitanaPrédios tipo caixão: uso de Matriz GUT na análise das manifestações patológicas de cinco edificações em Recife-PE e região metropolitanaPrédios tipo caixãoManifetações patológicasMatriz GUT.Edificios de ataúdesDefectos de construcciónMatriz GUT.Coffin BuildingsBuildings defectsGUT matrix.Coffin edifices buildings that commonly use resistant masonry as structural, without being based on recognized standards. This style of building began to be widespread in the 1970s in the Metropolitan Region of Recife due to the reduction of time and cost. From the 1990s, accidents in coffin buildings began to occur, along with a series of notifications of building defects. In order to map and carry out interdictions, in the necessary cases, several building inspection reports were carried out, either by determination of the Public Power or by initiative of the owners themselves. Five of these reports were selected for the present research, whose objective is to study the main defects of coffin buildings in three elements: foundation, superstructure and façade. To this end, the GUT Matrix was applied to determine the severity and resolution priority of the observed problems. After the analyses, it was shown that the damages present in the foundation and in the superstructure have priority in the resolution.Las edificaciones tipo ataúd son edificaciones que comúnmente utilizan como estructural mampostería resistente, sin basarse en estándares reconocidos. Este estilo de construcción comenzó a ser difundido en la década de 1970 en la Región Metropolitana de Recife debido a la reducción de tiempo y costo. A partir de la década de 1990 comenzaron a ocurrir accidentes en los edificios de ataúdes, junto con una serie de avisos de aparición de manifestaciones patológicas. Para la cartografía y realización de interdicciones, en los casos necesarios, se realizaban varios informes de inspección de obra, ya sea por determinación del Poder Público o por iniciativa de los propios propietarios. Cinco de estos informes fueron seleccionados para la presente investigación cuyo objetivo es estudiar las principales manifestaciones patológicas de los edificios tipo ataúd en tres elementos: cimentación, superestructura y fachada. Para ello se aplicó la Matriz GUT para determinar la severidad y prioridad de resolución de los problemas observados. Luego de los análisis se demostró que los daños presentes en la cimentación y en la superestructura tienen prioridad en la resolución.Prédios tipo caixão são edificações que utilizam comumente alvenaria resistente como estrutural, sem embasamento em normas reconhecidas. Esse estilo de edificação começou a ser bastante difundido na década de 1970 na Região Metropolitana do Recife devido à redução de tempo e custo. A partir dos anos 1990, sinistros em prédios caixão começaram a ocorrer, juntamente com uma série de notificações de aparecimento de manifestações patológicas. Com o intuito de mapear e realizar interdições, nos casos necessários, diversos laudos de inspeção predial foram realizados, seja por determinação do Poder Público ou por iniciativa dos próprios proprietários. Cinco desses laudos foram selecionados para a presente pesquisa cujo objetivo é estudar as principais manifestações patológicas de prédios do tipo caixão em três elementos: fundação, superestrutura e fachada. Para tal, aplicou-se a Matriz GUT para determinar a gravidade e a prioridade de resolução dos problemas observados. Após as análises, foi demonstrado que os danos presentes na fundação e na superestrutura têm prioridade na resolução.Research, Society and Development2022-07-16info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/3221910.33448/rsd-v11i9.32219Research, Society and Development; Vol. 11 No. 9; e47111932219Research, Society and Development; Vol. 11 Núm. 9; e47111932219Research, Society and Development; v. 11 n. 9; e471119322192525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIporhttps://rsdjournal.org/index.php/rsd/article/view/32219/27331Copyright (c) 2022 Lorena Vila Bela Costa; Laís Araújo Moura; Bruna Correia Teixeira; Eliana Cristina Barreto Monteiro; José Maria de Moura Júnior; Lucas Rodrigues Cavalcanti https://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessCosta, Lorena Vila Bela Moura, Laís Araújo Teixeira, Bruna Correia Monteiro, Eliana Cristina BarretoMoura Júnior, José Maria deCavalcanti , Lucas Rodrigues 2022-07-21T12:36:16Zoai:ojs.pkp.sfu.ca:article/32219Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:48:17.266616Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Box type buildings: use of GUT Matrix in the analysis of defects of five buildings in Recife-PE and metropolitan region
Edificios tipo ataúd: uso de GUT Matrix en el análisis de manifestaciones patológicas de cinco edificios en Recife-PE y región metropolitana
Prédios tipo caixão: uso de Matriz GUT na análise das manifestações patológicas de cinco edificações em Recife-PE e região metropolitana
title Box type buildings: use of GUT Matrix in the analysis of defects of five buildings in Recife-PE and metropolitan region
spellingShingle Box type buildings: use of GUT Matrix in the analysis of defects of five buildings in Recife-PE and metropolitan region
Costa, Lorena Vila Bela
Prédios tipo caixão
Manifetações patológicas
Matriz GUT.
Edificios de ataúdes
Defectos de construcción
Matriz GUT.
Coffin Buildings
Buildings defects
GUT matrix.
title_short Box type buildings: use of GUT Matrix in the analysis of defects of five buildings in Recife-PE and metropolitan region
title_full Box type buildings: use of GUT Matrix in the analysis of defects of five buildings in Recife-PE and metropolitan region
title_fullStr Box type buildings: use of GUT Matrix in the analysis of defects of five buildings in Recife-PE and metropolitan region
title_full_unstemmed Box type buildings: use of GUT Matrix in the analysis of defects of five buildings in Recife-PE and metropolitan region
title_sort Box type buildings: use of GUT Matrix in the analysis of defects of five buildings in Recife-PE and metropolitan region
author Costa, Lorena Vila Bela
author_facet Costa, Lorena Vila Bela
Moura, Laís Araújo
Teixeira, Bruna Correia
Monteiro, Eliana Cristina Barreto
Moura Júnior, José Maria de
Cavalcanti , Lucas Rodrigues
author_role author
author2 Moura, Laís Araújo
Teixeira, Bruna Correia
Monteiro, Eliana Cristina Barreto
Moura Júnior, José Maria de
Cavalcanti , Lucas Rodrigues
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Costa, Lorena Vila Bela
Moura, Laís Araújo
Teixeira, Bruna Correia
Monteiro, Eliana Cristina Barreto
Moura Júnior, José Maria de
Cavalcanti , Lucas Rodrigues
dc.subject.por.fl_str_mv Prédios tipo caixão
Manifetações patológicas
Matriz GUT.
Edificios de ataúdes
Defectos de construcción
Matriz GUT.
Coffin Buildings
Buildings defects
GUT matrix.
topic Prédios tipo caixão
Manifetações patológicas
Matriz GUT.
Edificios de ataúdes
Defectos de construcción
Matriz GUT.
Coffin Buildings
Buildings defects
GUT matrix.
description Coffin edifices buildings that commonly use resistant masonry as structural, without being based on recognized standards. This style of building began to be widespread in the 1970s in the Metropolitan Region of Recife due to the reduction of time and cost. From the 1990s, accidents in coffin buildings began to occur, along with a series of notifications of building defects. In order to map and carry out interdictions, in the necessary cases, several building inspection reports were carried out, either by determination of the Public Power or by initiative of the owners themselves. Five of these reports were selected for the present research, whose objective is to study the main defects of coffin buildings in three elements: foundation, superstructure and façade. To this end, the GUT Matrix was applied to determine the severity and resolution priority of the observed problems. After the analyses, it was shown that the damages present in the foundation and in the superstructure have priority in the resolution.
publishDate 2022
dc.date.none.fl_str_mv 2022-07-16
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/32219
10.33448/rsd-v11i9.32219
url https://rsdjournal.org/index.php/rsd/article/view/32219
identifier_str_mv 10.33448/rsd-v11i9.32219
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/32219/27331
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 11 No. 9; e47111932219
Research, Society and Development; Vol. 11 Núm. 9; e47111932219
Research, Society and Development; v. 11 n. 9; e47111932219
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052717855670272