Evaluation of the performance in service and useful life of a multifamily residential building located in the city of Garanhuns-PE

Detalhes bibliográficos
Autor(a) principal: Soares, Renan Gustavo Pacheco
Data de Publicação: 2022
Outros Autores: Silva , Giullia Elen Aguiar da, Alves, Glória Emanuely de Oliveira, Rodrigues, Diego Nunes de Melo, Melo Júnior , José Valmir Barros de, Soares , Maryanne de Oliveira, Rocha , Lígia Veiga Franco, Castro , Monique Domingos de, Lopes, Juliana Melo, Pacheco, Carla Renata Xavier
Tipo de documento: Artigo
Idioma: por
Título da fonte: Research, Society and Development
Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/30964
Resumo: The functional performance and healthiness of the building are fundamental elements in civil construction, guaranteeing the absence of pathologies that interfere with its performance. Buildings must provide comfort and safety for the people who inhabit them. This study aimed to verify the technical, functional and maintenance compliances of the constructive components of a multifamily building, in the city of Garanhuns, Pernambuco, Brazil, seeking the diagnosis of pathological manifestations and their causes, according to the national building inspection standard. , by recommendations OP-003-2015 and by NBR 13752:92 (ABNT, 1996); NBR 6118 (ABNT, 2014); NBR 15775 (ABNT, 2013); NBR 7200 (ABNT, 19980); NBR 13281 (ABNT, 2005) and NBR 7584 (ABNT, 2012). In the methodology, bibliographic research, exploratory research and case study were used. The data obtained were subjected to investigation scope, credibility and information adjustments based on the technical quality of the analyses, the building inspection carried out was level 1. The study was prepared based on the basis of the analysis of risks associated with environmental use and exposure. The results found allowed the characterization of technical conformities and performance in service of the property, highlighting electrical and structural problems as the main problems to be repaired.
id UNIFEI_27a4434bb2d0ab5d5c6c6513ad9d94ca
oai_identifier_str oai:ojs.pkp.sfu.ca:article/30964
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Evaluation of the performance in service and useful life of a multifamily residential building located in the city of Garanhuns-PEEvaluación del desempeño en servicio y vida útil de un edificio residencial multifamiliar ubicado en la ciudad de Garanhuns-PEAvaliação do desempenho em serviço e vida útil de uma edificação residencial multifamiliar situada na cidade de Garanhuns-PEDesempenhoPatologiasConformidadesDiagnóstico.DesempeñoPatologíasConformidadesDiagnóstico.PerformancePathologiesConformitiesDiagnosis.The functional performance and healthiness of the building are fundamental elements in civil construction, guaranteeing the absence of pathologies that interfere with its performance. Buildings must provide comfort and safety for the people who inhabit them. This study aimed to verify the technical, functional and maintenance compliances of the constructive components of a multifamily building, in the city of Garanhuns, Pernambuco, Brazil, seeking the diagnosis of pathological manifestations and their causes, according to the national building inspection standard. , by recommendations OP-003-2015 and by NBR 13752:92 (ABNT, 1996); NBR 6118 (ABNT, 2014); NBR 15775 (ABNT, 2013); NBR 7200 (ABNT, 19980); NBR 13281 (ABNT, 2005) and NBR 7584 (ABNT, 2012). In the methodology, bibliographic research, exploratory research and case study were used. The data obtained were subjected to investigation scope, credibility and information adjustments based on the technical quality of the analyses, the building inspection carried out was level 1. The study was prepared based on the basis of the analysis of risks associated with environmental use and exposure. The results found allowed the characterization of technical conformities and performance in service of the property, highlighting electrical and structural problems as the main problems to be repaired.El desempeño funcional y la salubridad del edificio son elementos fundamentales en la construcción civil, garantizando la ausencia de patologías que interfieran en su desempeño. Los edificios deben brindar comodidad y seguridad a las personas que los habitan. Este estudio tuvo como objetivo verificar las conformidades técnicas, funcionales y de mantenimiento de los componentes constructivos de un edificio multifamiliar, en la ciudad de Garanhuns, Pernambuco, Brasil, buscando el diagnóstico de manifestaciones patológicas y sus causas, de acuerdo con la norma nacional de inspección de edificios. , por las recomendaciones OP-003-2015 y por la NBR 13752:92 (ABNT, 1996); NBR 6118 (ABNT, 2014); NBR 15775 (ABNT, 2013); NBR 7200 (ABNT, 19980); NBR 13281 (ABNT, 2005) y NBR 7584 (ABNT, 2012). En la metodología se utilizó la investigación bibliográfica, la investigación exploratoria y el estudio de caso. Los datos obtenidos se sometieron a investigación de alcance, credibilidad y ajustes de información con base en la calidad técnica de los análisis, la inspección de obra realizada fue de nivel 1. El estudio se elaboró ​​en base al análisis de riesgos asociados al uso y exposición ambiental. Los resultados encontrados permitieron caracterizar las conformidades técnicas y el desempeño en servicio del inmueble, destacando los problemas eléctricos y estructurales como los principales problemas a reparar.O desempenho funcional e a salubridade da edificação são elementos fundamentais na construção civil, garantindo a ausência de patologias que interfiram no seu desempenho. As edificações devem apresentar conforto e segurança para as pessoas que nela habitam. Estre trabalho teve como objetivo verificar as conformidades técnicas, funcionais e de manutenção dos componentes construtivos de uma edificação multifamiliar, na cidade de Garanhuns, Pernambuco, Brasil. O foco foi definir um diagnóstico das manifestações patológicas e suas causas, de acordo com a norma de inspeção predial nacional, pelas recomendações OP-003-2015 e pelas NBR 13752 (ABNT, 1996); NBR 6118 (ABNT, 2014); NBR 15775 (ABNT, 2013); NBR 7200 (ABNT, 19980); NBR 13281 (ABNT, 2005) e NBR 7584 (ABNT, 2012). Na metodologia, foi usada a pesquisa bibliográfica, pesquisa exploratória e estudo de caso. Os dados obtidos foram submetidos a abrangência de investigação, credibilidade e ajustes de informações com base na qualidade técnica das análises, a inspeção predial realizada foi de nível 1. O estudo foi elaborado com base no embasamento da análise de riscos associado ao uso e exposição ambiental. Os resultados encontrados permitiram a caracterização das conformidades técnicas e do desempenho em serviço do imóvel, destacando para problemas de ordem elétrica e estrutural como principais problemas a serem reparados.Research, Society and Development2022-07-16info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/3096410.33448/rsd-v11i9.30964Research, Society and Development; Vol. 11 No. 9; e47611930964Research, Society and Development; Vol. 11 Núm. 9; e47611930964Research, Society and Development; v. 11 n. 9; e476119309642525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIporhttps://rsdjournal.org/index.php/rsd/article/view/30964/27340Copyright (c) 2022 Renan Gustavo Pacheco Soares; Giullia Elen Aguiar da Silva ; Glória Emanuely de Oliveira Alves; Diego Nunes de Melo Rodrigues; José Valmir Barros de Melo Júnior ; Maryanne de Oliveira Soares ; Lígia Veiga Franco Rocha ; Monique Domingos de Castro ; Juliana Melo Lopes; Carla Renata Xavier Pachecohttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccess Soares, Renan Gustavo Pacheco Silva , Giullia Elen Aguiar daAlves, Glória Emanuely de Oliveira Rodrigues, Diego Nunes de Melo Melo Júnior , José Valmir Barros de Soares , Maryanne de Oliveira Rocha , Lígia Veiga FrancoCastro , Monique Domingos de Lopes, Juliana MeloPacheco, Carla Renata Xavier 2022-07-21T12:36:16Zoai:ojs.pkp.sfu.ca:article/30964Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:47:30.671109Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Evaluation of the performance in service and useful life of a multifamily residential building located in the city of Garanhuns-PE
Evaluación del desempeño en servicio y vida útil de un edificio residencial multifamiliar ubicado en la ciudad de Garanhuns-PE
Avaliação do desempenho em serviço e vida útil de uma edificação residencial multifamiliar situada na cidade de Garanhuns-PE
title Evaluation of the performance in service and useful life of a multifamily residential building located in the city of Garanhuns-PE
spellingShingle Evaluation of the performance in service and useful life of a multifamily residential building located in the city of Garanhuns-PE
Soares, Renan Gustavo Pacheco
Desempenho
Patologias
Conformidades
Diagnóstico.
Desempeño
Patologías
Conformidades
Diagnóstico.
Performance
Pathologies
Conformities
Diagnosis.
title_short Evaluation of the performance in service and useful life of a multifamily residential building located in the city of Garanhuns-PE
title_full Evaluation of the performance in service and useful life of a multifamily residential building located in the city of Garanhuns-PE
title_fullStr Evaluation of the performance in service and useful life of a multifamily residential building located in the city of Garanhuns-PE
title_full_unstemmed Evaluation of the performance in service and useful life of a multifamily residential building located in the city of Garanhuns-PE
title_sort Evaluation of the performance in service and useful life of a multifamily residential building located in the city of Garanhuns-PE
author Soares, Renan Gustavo Pacheco
author_facet Soares, Renan Gustavo Pacheco
Silva , Giullia Elen Aguiar da
Alves, Glória Emanuely de Oliveira
Rodrigues, Diego Nunes de Melo
Melo Júnior , José Valmir Barros de
Soares , Maryanne de Oliveira
Rocha , Lígia Veiga Franco
Castro , Monique Domingos de
Lopes, Juliana Melo
Pacheco, Carla Renata Xavier
author_role author
author2 Silva , Giullia Elen Aguiar da
Alves, Glória Emanuely de Oliveira
Rodrigues, Diego Nunes de Melo
Melo Júnior , José Valmir Barros de
Soares , Maryanne de Oliveira
Rocha , Lígia Veiga Franco
Castro , Monique Domingos de
Lopes, Juliana Melo
Pacheco, Carla Renata Xavier
author2_role author
author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Soares, Renan Gustavo Pacheco
Silva , Giullia Elen Aguiar da
Alves, Glória Emanuely de Oliveira
Rodrigues, Diego Nunes de Melo
Melo Júnior , José Valmir Barros de
Soares , Maryanne de Oliveira
Rocha , Lígia Veiga Franco
Castro , Monique Domingos de
Lopes, Juliana Melo
Pacheco, Carla Renata Xavier
dc.subject.por.fl_str_mv Desempenho
Patologias
Conformidades
Diagnóstico.
Desempeño
Patologías
Conformidades
Diagnóstico.
Performance
Pathologies
Conformities
Diagnosis.
topic Desempenho
Patologias
Conformidades
Diagnóstico.
Desempeño
Patologías
Conformidades
Diagnóstico.
Performance
Pathologies
Conformities
Diagnosis.
description The functional performance and healthiness of the building are fundamental elements in civil construction, guaranteeing the absence of pathologies that interfere with its performance. Buildings must provide comfort and safety for the people who inhabit them. This study aimed to verify the technical, functional and maintenance compliances of the constructive components of a multifamily building, in the city of Garanhuns, Pernambuco, Brazil, seeking the diagnosis of pathological manifestations and their causes, according to the national building inspection standard. , by recommendations OP-003-2015 and by NBR 13752:92 (ABNT, 1996); NBR 6118 (ABNT, 2014); NBR 15775 (ABNT, 2013); NBR 7200 (ABNT, 19980); NBR 13281 (ABNT, 2005) and NBR 7584 (ABNT, 2012). In the methodology, bibliographic research, exploratory research and case study were used. The data obtained were subjected to investigation scope, credibility and information adjustments based on the technical quality of the analyses, the building inspection carried out was level 1. The study was prepared based on the basis of the analysis of risks associated with environmental use and exposure. The results found allowed the characterization of technical conformities and performance in service of the property, highlighting electrical and structural problems as the main problems to be repaired.
publishDate 2022
dc.date.none.fl_str_mv 2022-07-16
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/30964
10.33448/rsd-v11i9.30964
url https://rsdjournal.org/index.php/rsd/article/view/30964
identifier_str_mv 10.33448/rsd-v11i9.30964
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/30964/27340
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 11 No. 9; e47611930964
Research, Society and Development; Vol. 11 Núm. 9; e47611930964
Research, Society and Development; v. 11 n. 9; e47611930964
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052812510625792