Analysis of formatting channels prepared with manual file in rotary movement

Detalhes bibliográficos
Autor(a) principal: Mendes , Marly Mariany Sampaio
Data de Publicação: 2022
Outros Autores: Matos , Karina Damacena, Soares , Fabio Luiz
Tipo de documento: Artigo
Idioma: por
Título da fonte: Research, Society and Development
Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/37765
Resumo: Introduction: Seeking to streamline and facilitate the execution of endodontic treatment, studies improve techniques and instrumentation systems to perform procedures with less wear. The NiTi alloy has advantages over stainless steel. Its material considerably reduces the main flaws related to formatting, generating clinical application with better results. Objective: To compare the change in the width of root canals in artificial teeth using manual rotary nickel-titanium files with stainless steel K-files associated with Gates Gliden. Methodology: The study was carried out with thirty artificial lateral incisors divided into three groups. In the Control group, the teeth did not undergo any intervention. Group 1 was prepared with gates gliden burs and stainless steel manual files and group 2 with nickel titanium M files (Easy Equipamentos Odontologistas, Belo Horizonte, Brazil). Subsequently, radiographic images were obtained from all groups and the width of the canals were obtained at 5, 7, 10 and 14mm from the apex. Results. The mean widths found at 5mm, 7mm, 10mm and 14mm were respectively 0.303, 0408, 0723, 1.10 for the control group. Group 1 0.35, 047, 0786, 1.195. Group 2 0.423 , 0587, 0832, 1.267.Conclusion: Manual titanium nickel M files promoted less wear in the cervical third, when compared to the group where K-type files were used associated with Gliden gates burs. However, in the apical third, the M files promoted greater wear when compared to the K-type files associated with the gates gliden burs.
id UNIFEI_29394cc07e39d940079d726eb56a7727
oai_identifier_str oai:ojs.pkp.sfu.ca:article/37765
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Analysis of formatting channels prepared with manual file in rotary movementAnálisis de formato de canales preparados con lima manual en movimiento rotatorioAnálise de formatação de canais preparados com lima manual em movimento rotatórioPreparación de conductos radicularesEndodonciaNíquel-Titanio.Root canal preparationEndodonticsNickel-TitaniumPreparo de canal radicularEndodontiaNíquel-Titânio.Introduction: Seeking to streamline and facilitate the execution of endodontic treatment, studies improve techniques and instrumentation systems to perform procedures with less wear. The NiTi alloy has advantages over stainless steel. Its material considerably reduces the main flaws related to formatting, generating clinical application with better results. Objective: To compare the change in the width of root canals in artificial teeth using manual rotary nickel-titanium files with stainless steel K-files associated with Gates Gliden. Methodology: The study was carried out with thirty artificial lateral incisors divided into three groups. In the Control group, the teeth did not undergo any intervention. Group 1 was prepared with gates gliden burs and stainless steel manual files and group 2 with nickel titanium M files (Easy Equipamentos Odontologistas, Belo Horizonte, Brazil). Subsequently, radiographic images were obtained from all groups and the width of the canals were obtained at 5, 7, 10 and 14mm from the apex. Results. The mean widths found at 5mm, 7mm, 10mm and 14mm were respectively 0.303, 0408, 0723, 1.10 for the control group. Group 1 0.35, 047, 0786, 1.195. Group 2 0.423 , 0587, 0832, 1.267.Conclusion: Manual titanium nickel M files promoted less wear in the cervical third, when compared to the group where K-type files were used associated with Gliden gates burs. However, in the apical third, the M files promoted greater wear when compared to the K-type files associated with the gates gliden burs.Introducción: Buscando agilizar y facilitar la ejecución del tratamiento de endodoncia, los estudios mejoran técnicas y sistemas de instrumentación para realizar procedimientos con menor desgaste. La aleación NiTi tiene ventajas sobre el acero inoxidable. Su material reduce considerablemente las principales fallas relacionadas con el formato, generando una aplicación clínica con mejores resultados. Objetivo: Comparar el cambio en el ancho de los conductos radiculares en dientes artificiales utilizando limas rotatorias manuales de níquel-titanio con limas K de acero inoxidable asociadas a Gates Gliden. Metodología: El estudio se realizó con treinta incisivos laterales artificiales divididos en tres grupos. En el grupo Control, los dientes no sufrieron ninguna intervención. El grupo 1 se preparó con fresas gates gliden y limas manuales de acero inoxidable y el grupo 2 con limas M de níquel titanio (Easy Equipamentos Odontologistas, Belo Horizonte, Brasil). Posteriormente se obtuvieron imágenes radiográficas de todos los grupos y se obtuvo el ancho de los conductos a 5, 7, 10 y 14 mm del ápice. Resultados. Los anchos medios encontrados a 5 mm, 7 mm, 10 mm y 14 mm fueron respectivamente 0,303, 0408, 0723, 1,10 para el grupo de control. Grupo 1 0,35, 047, 0786, 1,195. Grupo 2 0.423, 0587, 0832, 1.267. Conclusión: Las limas manuales de titanio níquel M promovieron un menor desgaste en el tercio cervical, en comparación con el grupo donde se utilizaron limas tipo K asociadas a fresas Gliden gates. Sin embargo, en el tercio apical, las limas M promovieron un mayor desgaste en comparación con las limas tipo K asociadas con las fresas gate gliden.Introdução: Buscando agilizar e facilitar a execução do tratamento endodôntico, estudos aprimoram técnicas e sistemas de instrumentação para realização de procedimentos com menor desgaste. A liga de NiTi apresenta vantagens em relação ao aço inoxidável. Seu material diminui consideravelmente as principais falhas relacionadas à formatação gerando aplicação clínica com melhores resultados. Objetivo: Comparar a alteração da largura dos canais radiculares de dentes artificiais utilizando limas rotatórias manuais de níquel titânio com limas tipo K de aço inoxidável associadas a Gates Gliden. Metodologia: O estudo foi realizado com trinta incisivos laterais artificiais divididos em três grupos. No grupo Controle os dentes não sofreram qualquer intervenção. O grupo 1 foi preparado com brocas de gates gliden e limas manuais de aço inoxidável e o grupo 2 com limas de níquel titânio M (Easy Equipamentos Odontológicos, Belo Horizonte, Brasil). Posteriormente imagens radiográficas foram obtidas de todos os grupos e a largura dos canais foram obtidas a 5, 7, 10 e 14mm do ápice. Resultados. As médias das larguras encontradas a 5mm, 7mm, 10mm e 14mm foram respectivamente grupo controle 0.303, 0408, 0723, 1.10. Grupo 1 0,35, 047, 0786, 1,195. Grupo 2 0,423, 0587, 0832, 1,267. Conclusão: As limas manuais de níquel titânio M promoveram um menor desgaste no terço cervical, quando comparado ao grupo onde foi utilizado as limas tipo K associadas as brocas de gates gliden. Entretanto, no terço apical as limas M promoveram maior degaste quando comparado com as limas tipo K associadas as brocas gates gliden.Research, Society and Development2022-12-02info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/3776510.33448/rsd-v11i16.37765Research, Society and Development; Vol. 11 No. 16; e08111637765Research, Society and Development; Vol. 11 Núm. 16; e08111637765Research, Society and Development; v. 11 n. 16; e081116377652525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIporhttps://rsdjournal.org/index.php/rsd/article/view/37765/31486Copyright (c) 2022 Marly Mariany Sampaio Mendes ; Karina Damacena Matos ; Fabio Luiz Soares https://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessMendes , Marly Mariany Sampaio Matos , Karina Damacena Soares , Fabio Luiz 2022-12-18T18:26:42Zoai:ojs.pkp.sfu.ca:article/37765Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:51:48.545060Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Analysis of formatting channels prepared with manual file in rotary movement
Análisis de formato de canales preparados con lima manual en movimiento rotatorio
Análise de formatação de canais preparados com lima manual em movimento rotatório
title Analysis of formatting channels prepared with manual file in rotary movement
spellingShingle Analysis of formatting channels prepared with manual file in rotary movement
Mendes , Marly Mariany Sampaio
Preparación de conductos radiculares
Endodoncia
Níquel-Titanio.
Root canal preparation
Endodontics
Nickel-Titanium
Preparo de canal radicular
Endodontia
Níquel-Titânio.
title_short Analysis of formatting channels prepared with manual file in rotary movement
title_full Analysis of formatting channels prepared with manual file in rotary movement
title_fullStr Analysis of formatting channels prepared with manual file in rotary movement
title_full_unstemmed Analysis of formatting channels prepared with manual file in rotary movement
title_sort Analysis of formatting channels prepared with manual file in rotary movement
author Mendes , Marly Mariany Sampaio
author_facet Mendes , Marly Mariany Sampaio
Matos , Karina Damacena
Soares , Fabio Luiz
author_role author
author2 Matos , Karina Damacena
Soares , Fabio Luiz
author2_role author
author
dc.contributor.author.fl_str_mv Mendes , Marly Mariany Sampaio
Matos , Karina Damacena
Soares , Fabio Luiz
dc.subject.por.fl_str_mv Preparación de conductos radiculares
Endodoncia
Níquel-Titanio.
Root canal preparation
Endodontics
Nickel-Titanium
Preparo de canal radicular
Endodontia
Níquel-Titânio.
topic Preparación de conductos radiculares
Endodoncia
Níquel-Titanio.
Root canal preparation
Endodontics
Nickel-Titanium
Preparo de canal radicular
Endodontia
Níquel-Titânio.
description Introduction: Seeking to streamline and facilitate the execution of endodontic treatment, studies improve techniques and instrumentation systems to perform procedures with less wear. The NiTi alloy has advantages over stainless steel. Its material considerably reduces the main flaws related to formatting, generating clinical application with better results. Objective: To compare the change in the width of root canals in artificial teeth using manual rotary nickel-titanium files with stainless steel K-files associated with Gates Gliden. Methodology: The study was carried out with thirty artificial lateral incisors divided into three groups. In the Control group, the teeth did not undergo any intervention. Group 1 was prepared with gates gliden burs and stainless steel manual files and group 2 with nickel titanium M files (Easy Equipamentos Odontologistas, Belo Horizonte, Brazil). Subsequently, radiographic images were obtained from all groups and the width of the canals were obtained at 5, 7, 10 and 14mm from the apex. Results. The mean widths found at 5mm, 7mm, 10mm and 14mm were respectively 0.303, 0408, 0723, 1.10 for the control group. Group 1 0.35, 047, 0786, 1.195. Group 2 0.423 , 0587, 0832, 1.267.Conclusion: Manual titanium nickel M files promoted less wear in the cervical third, when compared to the group where K-type files were used associated with Gliden gates burs. However, in the apical third, the M files promoted greater wear when compared to the K-type files associated with the gates gliden burs.
publishDate 2022
dc.date.none.fl_str_mv 2022-12-02
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/37765
10.33448/rsd-v11i16.37765
url https://rsdjournal.org/index.php/rsd/article/view/37765
identifier_str_mv 10.33448/rsd-v11i16.37765
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/37765/31486
dc.rights.driver.fl_str_mv Copyright (c) 2022 Marly Mariany Sampaio Mendes ; Karina Damacena Matos ; Fabio Luiz Soares
https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2022 Marly Mariany Sampaio Mendes ; Karina Damacena Matos ; Fabio Luiz Soares
https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 11 No. 16; e08111637765
Research, Society and Development; Vol. 11 Núm. 16; e08111637765
Research, Society and Development; v. 11 n. 16; e08111637765
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052730072629248