Influence of type of metal alloy and penetration limit in determining the working length with two apex locators
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Research, Society and Development |
Texto Completo: | https://rsdjournal.org/index.php/rsd/article/view/25544 |
Resumo: | This ex vivo study aimed to evaluate the precision of two electronic foramen locators (Root ZX mini and RomiApex A15) inserting the manual Flexofile or NiTi endodontic files until reaching the apical foramen or surpassing it. Sixty mesial root canals of mandibular molars were selected. Root canal real length measurement and odontometry were performed after the access cavity surgery, cervical pre-flaring, and apical preparation. The precision of the electronic foramen locators was verified at each instrumentation phase, comparing the electronic measurements with the real length. The 3-way ANOVA test was used to evaluate the error of electronic measurements, and a significance level was set at 5%. At the first odontometry, the RZX was significantly more precise than the A15 (p<0,0001). After the second odontometry, the best results were observed when the penetration limit was restricted to the apical foramen. After the third odontometry, statistical differences were found for apex locator (p<0,0001), penetration limit (p<0,05), and metallic alloy (p=0,01). Manual instruments used to perform the odontometry should be inserted only until the foramen level. The use of NiTi files improves the precision of electronic foramen locators. |
id |
UNIFEI_3645b29e8fdf7fa8431d4679b11f1a75 |
---|---|
oai_identifier_str |
oai:ojs.pkp.sfu.ca:article/25544 |
network_acronym_str |
UNIFEI |
network_name_str |
Research, Society and Development |
repository_id_str |
|
spelling |
Influence of type of metal alloy and penetration limit in determining the working length with two apex locatorsInfluencia del tipo de aleación de metal y del límite de penetración en la determinación de la longitud de trabajo con dos localizadores de ápiceInfluência do tipo de liga metálica e do limite de penetração na determinação do comprimento de trabalho com dois localizadores apicais AleacionesEndodonciaOdontometría.AlloysEndodonticsOdontometry.LigasEndodontiaOdontometria.This ex vivo study aimed to evaluate the precision of two electronic foramen locators (Root ZX mini and RomiApex A15) inserting the manual Flexofile or NiTi endodontic files until reaching the apical foramen or surpassing it. Sixty mesial root canals of mandibular molars were selected. Root canal real length measurement and odontometry were performed after the access cavity surgery, cervical pre-flaring, and apical preparation. The precision of the electronic foramen locators was verified at each instrumentation phase, comparing the electronic measurements with the real length. The 3-way ANOVA test was used to evaluate the error of electronic measurements, and a significance level was set at 5%. At the first odontometry, the RZX was significantly more precise than the A15 (p<0,0001). After the second odontometry, the best results were observed when the penetration limit was restricted to the apical foramen. After the third odontometry, statistical differences were found for apex locator (p<0,0001), penetration limit (p<0,05), and metallic alloy (p=0,01). Manual instruments used to perform the odontometry should be inserted only until the foramen level. The use of NiTi files improves the precision of electronic foramen locators.El objetivo de este estudio ex vivo fue evaluar la precisión de dos localizadores de ápice (Root ZX mini y RomiApex A15) insertando las limas endodónticas manuales Flexofile o NiTi hasta llegar al foramen apical o superarlo. Se seleccionaron sesenta conductos radiculares mesiales de molares mandibulares. La medición de la longitud real del conducto radicular y la odontometría se realizaron después de la cirugía de la cavidad de acceso, el abocardado cervical y la preparación apical. La precisión de los localizadores de ápices se verificó en cada fase de instrumentación, comparando las medidas electrónicas con la longitud real. Se utilizó la prueba ANOVA de 3 vías para evaluar el error de las mediciones electrónicas y se estableció un nivel de significancia del 5%. En la primera odontometría, el RZX fue significativamente más preciso que el A15 (p <0,0001). Después de la segunda odontometría, los mejores resultados se observaron cuando el límite de penetración se restringió al foramen apical. Después de la tercera odontometría, se encontraron diferencias estadísticas para localizador de ápice (p <0,0001), límite de penetración (p <0,05) y aleación metálica (p = 0,01). Los instrumentos manuales utilizados para realizar la odontometría deben insertarse solo hasta el nivel del foramen. El uso de limas NiTi mejora la precisión de los localizadores de ápices.O objetivo deste estudo ex vivo foi avaliar a precisão de dois localizadores apicais (Root ZX mini e RomiApex A15) inserindo as limas endodônticas manuais Flexofile ou NiTi até atingir o forame apical ou ultrapassá-lo. Sessenta canais radiculares mesiais de molares inferiores foram selecionados. A mensuração do comprimento real do canal radicular e a odontometria foram realizadas após a cirurgia de acesso, pré-alargamento cervical e preparo apical. A precisão dos localizadores apicais foi verificada a cada fase de instrumentação, comparando as medidas eletrônicas com o comprimento real. O teste ANOVA de 3 fatores foi usado para avaliar o erro das medidas eletrônicas e o nível de significância foi estabelecido em 5%. Na primeira odontometria, o RZX foi significativamente mais preciso do que o A15 (p <0,0001). Após a segunda odontometria, os melhores resultados foram observados quando o limite de penetração ficou restrito ao forame apical. Após a terceira odontometria, foram encontradas diferenças estatísticas para localizador apical (p <0,0001), limite de penetração (p <0,05) e liga metálica (p = 0,01). Os instrumentos manuais utilizados para a realização da odontometria devem ser inseridos somente até o nível do forame. O uso de limas NiTi melhora a precisão dos localizadores apicais.Research, Society and Development2022-01-19info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/2554410.33448/rsd-v11i2.25544Research, Society and Development; Vol. 11 No. 2; e11911225544Research, Society and Development; Vol. 11 Núm. 2; e11911225544Research, Society and Development; v. 11 n. 2; e119112255442525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIenghttps://rsdjournal.org/index.php/rsd/article/view/25544/22360Copyright (c) 2022 Enio Cordeiro Amaral; Juliana Larocca de Geus; Bruno Carvalho de Vasconcelos; Nilton Vivacqua-Gomes https://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessAmaral, Enio CordeiroGeus, Juliana Larocca de Vasconcelos, Bruno Carvalho de Vivacqua-Gomes , Nilton 2022-02-07T01:42:50Zoai:ojs.pkp.sfu.ca:article/25544Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:43:48.247111Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false |
dc.title.none.fl_str_mv |
Influence of type of metal alloy and penetration limit in determining the working length with two apex locators Influencia del tipo de aleación de metal y del límite de penetración en la determinación de la longitud de trabajo con dos localizadores de ápice Influência do tipo de liga metálica e do limite de penetração na determinação do comprimento de trabalho com dois localizadores apicais |
title |
Influence of type of metal alloy and penetration limit in determining the working length with two apex locators |
spellingShingle |
Influence of type of metal alloy and penetration limit in determining the working length with two apex locators Amaral, Enio Cordeiro Aleaciones Endodoncia Odontometría. Alloys Endodontics Odontometry. Ligas Endodontia Odontometria. |
title_short |
Influence of type of metal alloy and penetration limit in determining the working length with two apex locators |
title_full |
Influence of type of metal alloy and penetration limit in determining the working length with two apex locators |
title_fullStr |
Influence of type of metal alloy and penetration limit in determining the working length with two apex locators |
title_full_unstemmed |
Influence of type of metal alloy and penetration limit in determining the working length with two apex locators |
title_sort |
Influence of type of metal alloy and penetration limit in determining the working length with two apex locators |
author |
Amaral, Enio Cordeiro |
author_facet |
Amaral, Enio Cordeiro Geus, Juliana Larocca de Vasconcelos, Bruno Carvalho de Vivacqua-Gomes , Nilton |
author_role |
author |
author2 |
Geus, Juliana Larocca de Vasconcelos, Bruno Carvalho de Vivacqua-Gomes , Nilton |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Amaral, Enio Cordeiro Geus, Juliana Larocca de Vasconcelos, Bruno Carvalho de Vivacqua-Gomes , Nilton |
dc.subject.por.fl_str_mv |
Aleaciones Endodoncia Odontometría. Alloys Endodontics Odontometry. Ligas Endodontia Odontometria. |
topic |
Aleaciones Endodoncia Odontometría. Alloys Endodontics Odontometry. Ligas Endodontia Odontometria. |
description |
This ex vivo study aimed to evaluate the precision of two electronic foramen locators (Root ZX mini and RomiApex A15) inserting the manual Flexofile or NiTi endodontic files until reaching the apical foramen or surpassing it. Sixty mesial root canals of mandibular molars were selected. Root canal real length measurement and odontometry were performed after the access cavity surgery, cervical pre-flaring, and apical preparation. The precision of the electronic foramen locators was verified at each instrumentation phase, comparing the electronic measurements with the real length. The 3-way ANOVA test was used to evaluate the error of electronic measurements, and a significance level was set at 5%. At the first odontometry, the RZX was significantly more precise than the A15 (p<0,0001). After the second odontometry, the best results were observed when the penetration limit was restricted to the apical foramen. After the third odontometry, statistical differences were found for apex locator (p<0,0001), penetration limit (p<0,05), and metallic alloy (p=0,01). Manual instruments used to perform the odontometry should be inserted only until the foramen level. The use of NiTi files improves the precision of electronic foramen locators. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-01-19 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://rsdjournal.org/index.php/rsd/article/view/25544 10.33448/rsd-v11i2.25544 |
url |
https://rsdjournal.org/index.php/rsd/article/view/25544 |
identifier_str_mv |
10.33448/rsd-v11i2.25544 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://rsdjournal.org/index.php/rsd/article/view/25544/22360 |
dc.rights.driver.fl_str_mv |
https://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Research, Society and Development |
publisher.none.fl_str_mv |
Research, Society and Development |
dc.source.none.fl_str_mv |
Research, Society and Development; Vol. 11 No. 2; e11911225544 Research, Society and Development; Vol. 11 Núm. 2; e11911225544 Research, Society and Development; v. 11 n. 2; e11911225544 2525-3409 reponame:Research, Society and Development instname:Universidade Federal de Itajubá (UNIFEI) instacron:UNIFEI |
instname_str |
Universidade Federal de Itajubá (UNIFEI) |
instacron_str |
UNIFEI |
institution |
UNIFEI |
reponame_str |
Research, Society and Development |
collection |
Research, Society and Development |
repository.name.fl_str_mv |
Research, Society and Development - Universidade Federal de Itajubá (UNIFEI) |
repository.mail.fl_str_mv |
rsd.articles@gmail.com |
_version_ |
1797052792456609792 |