Microbiological evaluation performed in hospital aerosolterapy equipment

Detalhes bibliográficos
Autor(a) principal: Silva Neto, Firmino Marcelino da
Data de Publicação: 2020
Outros Autores: Sobreira, Ana Laura de Cabral, Cordeiro, Laisa Vilar, Carmo, Egberto Santos
Tipo de documento: Artigo
Idioma: por
Título da fonte: Research, Society and Development
Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/4473
Resumo: The investigation of microbiological contamination in hospital use equipment makes it possible to assess whether the decontamination processes adopted by the health service are adequate and contribute to minimize the risks of Health Care-Related Infections. Based on this, this study aimed to evaluate the microbiological contamination of nebulizers in three health services and also to make a brief association between contamination and reprocessing methods. Ten samples of nebulizers (mask and reservoir cup) were collected, with swabs moistened with saline solution and sown in culture media selective for bacteria and fungi. After 24-48 hours of incubation at 37 °C, identification by biochemical tests of positive cultures was performed. An analysis of the health unit reprocessing protocols was also carried out. 40% of the analyzed samples presented contamination by some type of microorganism. Enterobacter sp., Gram positive bacilli and coagulase-negative Staphylococcus were the specimens found in this study. Only one Hospital, which followed the recommended for pre-washing and disinfection product, presented all its samples without microbiological contamination. Thus, it can be concluded that there is weakness in the reprocessing of these contaminated equipment, whose failures in disinfection impose risk to the user's health.
id UNIFEI_51ca59523e35bc2833fe7ab906b04f9c
oai_identifier_str oai:ojs.pkp.sfu.ca:article/4473
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Microbiological evaluation performed in hospital aerosolterapy equipmentEvaluación microbiológica realizada en equipos hospitalarios de terapia de aerosolAvaliação microbiológica realizada em equipamentos de aerossolterapia hospitalarHospital infectionRespiratory diseasesMicrobiological contamination.Infecção hospitalarDoenças respiratóriasContaminação microbiológica.Infección hospitalariaEnfermedades respiratoriasContaminación microbiológica.The investigation of microbiological contamination in hospital use equipment makes it possible to assess whether the decontamination processes adopted by the health service are adequate and contribute to minimize the risks of Health Care-Related Infections. Based on this, this study aimed to evaluate the microbiological contamination of nebulizers in three health services and also to make a brief association between contamination and reprocessing methods. Ten samples of nebulizers (mask and reservoir cup) were collected, with swabs moistened with saline solution and sown in culture media selective for bacteria and fungi. After 24-48 hours of incubation at 37 °C, identification by biochemical tests of positive cultures was performed. An analysis of the health unit reprocessing protocols was also carried out. 40% of the analyzed samples presented contamination by some type of microorganism. Enterobacter sp., Gram positive bacilli and coagulase-negative Staphylococcus were the specimens found in this study. Only one Hospital, which followed the recommended for pre-washing and disinfection product, presented all its samples without microbiological contamination. Thus, it can be concluded that there is weakness in the reprocessing of these contaminated equipment, whose failures in disinfection impose risk to the user's health.La investigación de la contaminación microbiológica en los equipos para uso hospitalario nos permite evaluar si los procesos de descontaminación adoptados por el servicio de salud son adecuados y contribuye a minimizar los riesgos de infecciones relacionadas con la atención médica. En base a esto, este estudio tuvo como objetivo evaluar la contaminación microbiológica de los nebulizadores en tres servicios de salud y hacer una breve asociación entre la contaminación y los métodos de reprocesamiento. Se recogieron diez muestras de nebulizadores (mascarilla y copa de depósito), con hisopos humedecidos en solución salina y sembrados en un medio de cultivo selectivo para bacterias y hongos. Después de 24-48 horas de incubación a 37 ° C, se realizó la identificación mediante pruebas bioquímicas de cultivos positivos. También se realizó un análisis de los protocolos de reprocesamiento de la unidad de salud. El 40% de las muestras analizadas presentaron contaminación por algún tipo de microorganismo. Enterobacter sp., Bacilos grampositivos y Staphylococcus coagulasa negativo fueron las muestras encontradas en este estudio. Solo un hospital, que siguió lo recomendado para el producto de prelavado y desinfección, presentó todas sus muestras sin contaminación microbiológica. Por lo tanto, se puede concluir que existe una debilidad en el reprocesamiento de este equipo contaminado, cuyas fallas en la desinfección imponen riesgos para la salud del usuario.A investigação da contaminação microbiológica em equipamentos de uso hospitalar permite avaliar se os processos de descontaminação adotados pelo serviço de saúde são adequados e contribui para minimizar os riscos de infecções relacionadas à assistência à saúde. Com base nisso, este estudo teve como objetivo avaliar a contaminação microbiológica de nebulizadores em três serviços de saúde e fazer uma breve associação entre métodos de contaminação e reprocessamento. Dez amostras de nebulizadores (máscara e copo reservatório) foram coletadas, com swabs umedecidos em solução salina e semeado em meio de cultura seletivo para bactérias e fungos. Após 24-48 horas de incubação a 37 °C, foi realizada a identificação por testes bioquímicos de culturas positivas. Também foi realizada uma análise dos protocolos de reprocessamento das unidades de saúde. 40% das amostras analisadas apresentaram contaminação por algum tipo de microrganismo. Enterobacter sp., bacilos Gram-positivos e Staphylococcus coagulase-negativos foram as amostras encontradas neste estudo. Apenas um hospital, que seguiu o recomendado para o produto de pré-lavagem e desinfecção, apresentou todas as suas amostras sem contaminação microbiológica. Assim, pode-se concluir que há fragilidade no reprocessamento desses equipamentos contaminados, cujas falhas na desinfecção impõem riscos à saúde do usuário.Research, Society and Development2020-05-28info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/447310.33448/rsd-v9i7.4473Research, Society and Development; Vol. 9 No. 7; e615974473Research, Society and Development; Vol. 9 Núm. 7; e615974473Research, Society and Development; v. 9 n. 7; e6159744732525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIporhttps://rsdjournal.org/index.php/rsd/article/view/4473/4003Copyright (c) 2020 Ana Laura de Cabral Sobreira, Firmino Marcelino da Silva Neto, Laisa Vilar Cordeiro, Egberto Santos Carmoinfo:eu-repo/semantics/openAccessSilva Neto, Firmino Marcelino daSobreira, Ana Laura de CabralCordeiro, Laisa VilarCarmo, Egberto Santos2020-08-20T18:05:03Zoai:ojs.pkp.sfu.ca:article/4473Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:28:18.967100Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Microbiological evaluation performed in hospital aerosolterapy equipment
Evaluación microbiológica realizada en equipos hospitalarios de terapia de aerosol
Avaliação microbiológica realizada em equipamentos de aerossolterapia hospitalar
title Microbiological evaluation performed in hospital aerosolterapy equipment
spellingShingle Microbiological evaluation performed in hospital aerosolterapy equipment
Silva Neto, Firmino Marcelino da
Hospital infection
Respiratory diseases
Microbiological contamination.
Infecção hospitalar
Doenças respiratórias
Contaminação microbiológica.
Infección hospitalaria
Enfermedades respiratorias
Contaminación microbiológica.
title_short Microbiological evaluation performed in hospital aerosolterapy equipment
title_full Microbiological evaluation performed in hospital aerosolterapy equipment
title_fullStr Microbiological evaluation performed in hospital aerosolterapy equipment
title_full_unstemmed Microbiological evaluation performed in hospital aerosolterapy equipment
title_sort Microbiological evaluation performed in hospital aerosolterapy equipment
author Silva Neto, Firmino Marcelino da
author_facet Silva Neto, Firmino Marcelino da
Sobreira, Ana Laura de Cabral
Cordeiro, Laisa Vilar
Carmo, Egberto Santos
author_role author
author2 Sobreira, Ana Laura de Cabral
Cordeiro, Laisa Vilar
Carmo, Egberto Santos
author2_role author
author
author
dc.contributor.author.fl_str_mv Silva Neto, Firmino Marcelino da
Sobreira, Ana Laura de Cabral
Cordeiro, Laisa Vilar
Carmo, Egberto Santos
dc.subject.por.fl_str_mv Hospital infection
Respiratory diseases
Microbiological contamination.
Infecção hospitalar
Doenças respiratórias
Contaminação microbiológica.
Infección hospitalaria
Enfermedades respiratorias
Contaminación microbiológica.
topic Hospital infection
Respiratory diseases
Microbiological contamination.
Infecção hospitalar
Doenças respiratórias
Contaminação microbiológica.
Infección hospitalaria
Enfermedades respiratorias
Contaminación microbiológica.
description The investigation of microbiological contamination in hospital use equipment makes it possible to assess whether the decontamination processes adopted by the health service are adequate and contribute to minimize the risks of Health Care-Related Infections. Based on this, this study aimed to evaluate the microbiological contamination of nebulizers in three health services and also to make a brief association between contamination and reprocessing methods. Ten samples of nebulizers (mask and reservoir cup) were collected, with swabs moistened with saline solution and sown in culture media selective for bacteria and fungi. After 24-48 hours of incubation at 37 °C, identification by biochemical tests of positive cultures was performed. An analysis of the health unit reprocessing protocols was also carried out. 40% of the analyzed samples presented contamination by some type of microorganism. Enterobacter sp., Gram positive bacilli and coagulase-negative Staphylococcus were the specimens found in this study. Only one Hospital, which followed the recommended for pre-washing and disinfection product, presented all its samples without microbiological contamination. Thus, it can be concluded that there is weakness in the reprocessing of these contaminated equipment, whose failures in disinfection impose risk to the user's health.
publishDate 2020
dc.date.none.fl_str_mv 2020-05-28
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/4473
10.33448/rsd-v9i7.4473
url https://rsdjournal.org/index.php/rsd/article/view/4473
identifier_str_mv 10.33448/rsd-v9i7.4473
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/4473/4003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 9 No. 7; e615974473
Research, Society and Development; Vol. 9 Núm. 7; e615974473
Research, Society and Development; v. 9 n. 7; e615974473
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052650024337408