Influence of temperature variation on the generation of a photovoltaic system connected to the grid for power generation under field conditions

Detalhes bibliográficos
Autor(a) principal: Zampiva, Marcelo Machado Marquez
Data de Publicação: 2021
Outros Autores: Siqueira, Jair Antonio Cruz, Nogueira, Carlos Eduardo Camargo, Tokura, Luciene Kazue, Alovisi, Alessandra Mayumi Tokura, Foltz, Laura Luana, Prior, Maritane, Caneppele, Fernando de Lima
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Research, Society and Development
Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/23425
Resumo: This experiment aimed to analyze the temperature behavior of photovoltaic modules, with the efficiency of the on-grid photovoltaic system, installed at the State University of West Paraná - UNIOESTE, campus of Cascavel, Paraná. The photovoltaic system consists of two ropes, with a total power of 3.3 kWp. In the first period, it was found that the panel kept clean (Panel 2), during data collection, reached a higher efficiency during the first weeks and practically the same for the last weeks, compared to the dirty panel. Achieve an average efficiency of 13.73% and 14.39%, Panel 1 and Panel 2, respectively. For the second period, the average efficiency of both panels, with inclinations of 21° and 26°, was very close, being 14.25% (Panel 1) and 14.24% (Panel 2). The third period showed a difference in the efficiency of the panels, 13.7% (Panel 1) and 14.54% (Panel 2), with inclinations of 21° and 18°, respectively. The test of means identified that there was a difference between the levels of soiling of the modules, as well as their inclinations of 21° and 18°. As for the 21° and 26° inclinations, there was no significant difference, according to the Tukey Test at 5% significance.
id UNIFEI_b6c8bd63a135c2894ea12ff62025e95d
oai_identifier_str oai:ojs.pkp.sfu.ca:article/23425
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Influence of temperature variation on the generation of a photovoltaic system connected to the grid for power generation under field conditionsInfluencia de la variación de temperatura en la generación de uno sistema fotovoltaico conectado a la red para generación de energía eléctrica en condiciones de campoInfluência da variação de temperatura na geração de um sistema fotovoltaico conectado à rede para geração de energia elétrica em condições de campoSistema Solar FotovoltaicoMódulos FotovoltaicosInclinaçãoSujidadeEficiência.Photovoltaic Solar SystemPhotovoltaic ModulesInclinationDirtEfficiency.Sistema Solar FotovoltaicoMódulos FotovoltaicosInclinaciónSuciedadEficiencia.This experiment aimed to analyze the temperature behavior of photovoltaic modules, with the efficiency of the on-grid photovoltaic system, installed at the State University of West Paraná - UNIOESTE, campus of Cascavel, Paraná. The photovoltaic system consists of two ropes, with a total power of 3.3 kWp. In the first period, it was found that the panel kept clean (Panel 2), during data collection, reached a higher efficiency during the first weeks and practically the same for the last weeks, compared to the dirty panel. Achieve an average efficiency of 13.73% and 14.39%, Panel 1 and Panel 2, respectively. For the second period, the average efficiency of both panels, with inclinations of 21° and 26°, was very close, being 14.25% (Panel 1) and 14.24% (Panel 2). The third period showed a difference in the efficiency of the panels, 13.7% (Panel 1) and 14.54% (Panel 2), with inclinations of 21° and 18°, respectively. The test of means identified that there was a difference between the levels of soiling of the modules, as well as their inclinations of 21° and 18°. As for the 21° and 26° inclinations, there was no significant difference, according to the Tukey Test at 5% significance.Este experimento tuvo como objetivo analizar el comportamiento de la temperatura de los módulos fotovoltaicos, con la eficiencia del sistema fotovoltaico on-grid, instalado en la Universidad Estadual do Oeste de Paraná - UNIOESTE, campus de Cascavel, Paraná. El sistema fotovoltaico consta de dos ropes, con una potencia total de 3,3 kWp. En el primer período, se verificó que el panel se mantuvo limpio (Panel 2), durante la recolección de datos, alcanzó mayor eficiencia durante las primeras semanas y prácticamente la misma en las últimas semanas, en comparación con el panel sucio. Lograr una eficiencia promedio de 13,73% y 14,39%, Panel 1 y Panel 2, respectivamente. Para el segundo período, la eficiencia media de ambos paneles, con inclinaciones de 21° y 26°, fue muy cercana, siendo 14,25% (Panel 1) y 14,24% (Panel 2). El tercer período presentó diferencia en la eficiencia de los paneles, 13,7% (Panel 1) y 14,54% (Panel 2), con inclinaciones de 21° y 18°, respectivamente. La prueba de promedios identificó que había una diferencia entre los niveles de suciedad de los módulos, así como sus inclinaciones de 21° y 18°. En cuanto a las pendientes 21° y 26° no hubo diferencia significativa, de acuerdo con el Test de Tukey con significación del 5%.Este experimento teve como objetivo analisar o comportamento da temperatura dos módulos fotovoltaicos, com a eficiência do sistema fotovoltaico on-grid, instalado na Universidade Estadual do Oeste do Paraná - UNIOESTE, campus de Cascavel, Paraná. O sistema fotovoltaico consiste em duas ropes, com uma potência total de 3,3 kWp. No primeiro período, verificou-se que o painel se manteve limpo (Painel 2), durante a coleta de dados, alcançou maior eficiência durante as primeiras semanas e praticamente a mesma nas últimas semanas, em comparação com o painel sujo. Atingir uma eficiência média de 13,73% e 14,39%, Painel 1 e Painel 2, respectivamente. Para o segundo período, a eficiência média de ambos os painéis, com inclinações de 21° e 26°, foi muito próxima, sendo 14,25% (Painel 1) e 14,24% (Painel 2). O terceiro período apresentou diferença na eficiência dos painéis, 13,7% (Painel 1) e 14,54% (Painel 2), com inclinações de 21° e 18°, respectivamente. O teste de médias identificou que havia uma diferença entre os níveis de sujidade dos módulos, bem como suas inclinações de 21° e 18°. Quanto às inclinações 21° e 26° não houve diferença significativa, de acordo com o Teste de Tukey com significância de 5%.Research, Society and Development2021-12-12info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/2342510.33448/rsd-v10i16.23425Research, Society and Development; Vol. 10 No. 16; e274101623425Research, Society and Development; Vol. 10 Núm. 16; e274101623425Research, Society and Development; v. 10 n. 16; e2741016234252525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIenghttps://rsdjournal.org/index.php/rsd/article/view/23425/20926Copyright (c) 2021 Marcelo Machado Marquez Zampiva; Jair Antonio Cruz Siqueira; Carlos Eduardo Camargo Nogueira; Luciene Kazue Tokura; Alessandra Mayumi Tokura Alovisi; Laura Luana Foltz; Maritane Prior; Fernando de Lima Caneppelehttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessZampiva, Marcelo Machado Marquez Siqueira, Jair Antonio Cruz Nogueira, Carlos Eduardo Camargo Tokura, Luciene Kazue Alovisi, Alessandra Mayumi Tokura Foltz, Laura Luana Prior, MaritaneCaneppele, Fernando de Lima 2021-12-20T11:03:07Zoai:ojs.pkp.sfu.ca:article/23425Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:42:18.081916Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Influence of temperature variation on the generation of a photovoltaic system connected to the grid for power generation under field conditions
Influencia de la variación de temperatura en la generación de uno sistema fotovoltaico conectado a la red para generación de energía eléctrica en condiciones de campo
Influência da variação de temperatura na geração de um sistema fotovoltaico conectado à rede para geração de energia elétrica em condições de campo
title Influence of temperature variation on the generation of a photovoltaic system connected to the grid for power generation under field conditions
spellingShingle Influence of temperature variation on the generation of a photovoltaic system connected to the grid for power generation under field conditions
Zampiva, Marcelo Machado Marquez
Sistema Solar Fotovoltaico
Módulos Fotovoltaicos
Inclinação
Sujidade
Eficiência.
Photovoltaic Solar System
Photovoltaic Modules
Inclination
Dirt
Efficiency.
Sistema Solar Fotovoltaico
Módulos Fotovoltaicos
Inclinación
Suciedad
Eficiencia.
title_short Influence of temperature variation on the generation of a photovoltaic system connected to the grid for power generation under field conditions
title_full Influence of temperature variation on the generation of a photovoltaic system connected to the grid for power generation under field conditions
title_fullStr Influence of temperature variation on the generation of a photovoltaic system connected to the grid for power generation under field conditions
title_full_unstemmed Influence of temperature variation on the generation of a photovoltaic system connected to the grid for power generation under field conditions
title_sort Influence of temperature variation on the generation of a photovoltaic system connected to the grid for power generation under field conditions
author Zampiva, Marcelo Machado Marquez
author_facet Zampiva, Marcelo Machado Marquez
Siqueira, Jair Antonio Cruz
Nogueira, Carlos Eduardo Camargo
Tokura, Luciene Kazue
Alovisi, Alessandra Mayumi Tokura
Foltz, Laura Luana
Prior, Maritane
Caneppele, Fernando de Lima
author_role author
author2 Siqueira, Jair Antonio Cruz
Nogueira, Carlos Eduardo Camargo
Tokura, Luciene Kazue
Alovisi, Alessandra Mayumi Tokura
Foltz, Laura Luana
Prior, Maritane
Caneppele, Fernando de Lima
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Zampiva, Marcelo Machado Marquez
Siqueira, Jair Antonio Cruz
Nogueira, Carlos Eduardo Camargo
Tokura, Luciene Kazue
Alovisi, Alessandra Mayumi Tokura
Foltz, Laura Luana
Prior, Maritane
Caneppele, Fernando de Lima
dc.subject.por.fl_str_mv Sistema Solar Fotovoltaico
Módulos Fotovoltaicos
Inclinação
Sujidade
Eficiência.
Photovoltaic Solar System
Photovoltaic Modules
Inclination
Dirt
Efficiency.
Sistema Solar Fotovoltaico
Módulos Fotovoltaicos
Inclinación
Suciedad
Eficiencia.
topic Sistema Solar Fotovoltaico
Módulos Fotovoltaicos
Inclinação
Sujidade
Eficiência.
Photovoltaic Solar System
Photovoltaic Modules
Inclination
Dirt
Efficiency.
Sistema Solar Fotovoltaico
Módulos Fotovoltaicos
Inclinación
Suciedad
Eficiencia.
description This experiment aimed to analyze the temperature behavior of photovoltaic modules, with the efficiency of the on-grid photovoltaic system, installed at the State University of West Paraná - UNIOESTE, campus of Cascavel, Paraná. The photovoltaic system consists of two ropes, with a total power of 3.3 kWp. In the first period, it was found that the panel kept clean (Panel 2), during data collection, reached a higher efficiency during the first weeks and practically the same for the last weeks, compared to the dirty panel. Achieve an average efficiency of 13.73% and 14.39%, Panel 1 and Panel 2, respectively. For the second period, the average efficiency of both panels, with inclinations of 21° and 26°, was very close, being 14.25% (Panel 1) and 14.24% (Panel 2). The third period showed a difference in the efficiency of the panels, 13.7% (Panel 1) and 14.54% (Panel 2), with inclinations of 21° and 18°, respectively. The test of means identified that there was a difference between the levels of soiling of the modules, as well as their inclinations of 21° and 18°. As for the 21° and 26° inclinations, there was no significant difference, according to the Tukey Test at 5% significance.
publishDate 2021
dc.date.none.fl_str_mv 2021-12-12
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/23425
10.33448/rsd-v10i16.23425
url https://rsdjournal.org/index.php/rsd/article/view/23425
identifier_str_mv 10.33448/rsd-v10i16.23425
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/23425/20926
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 10 No. 16; e274101623425
Research, Society and Development; Vol. 10 Núm. 16; e274101623425
Research, Society and Development; v. 10 n. 16; e274101623425
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052697939017728