Union endurance of adhesive systems in humid dentin and dry dentin: integrative review
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Research, Society and Development |
Texto Completo: | https://rsdjournal.org/index.php/rsd/article/view/13894 |
Resumo: | Adhesion to dentin is difficult because it is a structure with high water composition, over the years the clinical protocols, as well as the adhesive systems have been changed, in order to improve the union endurance and simplify the technique. Through a integrative review, discuss the union endurance of adhesive systems in wet and dry dentin in order to improve clinical protocols. The selection of articles was carried out through the virtual health library (VHL), obtaining articles from the MEDLINE, LILACS, Biblioteca Brasileira de Odontologia (BBO) databases, in addition to searches on Google® Scholar, using the indexed terms: “Dentin”, “Dentina”, "Dentin-Bonding Agents" and “Adesivos dentinários”. Articles published between 2013 and 2020 were included. The selected studies could be clinical or laboratory, in wet and dry dentin, using tensile, microtensile or shear strength tests in the studies in vitro, with conventional, self-etching and / or universal adhesive systems, published as short articles, posters or literature reviews were excluded. 969 were found, 8 articles were selected according to the inclusion criteria, all studies addressed the degree dentin moisture content as a limiting factor in the quality of adhesion, as well as the operator's knowledge about the composition of the adhesive system used. Universal adhesive systems were effective on both wet and dry dentin, conventional adhesive systems were efficient only on wet dentin. |
id |
UNIFEI_e4572986c1ade99e101ae37993e9641b |
---|---|
oai_identifier_str |
oai:ojs.pkp.sfu.ca:article/13894 |
network_acronym_str |
UNIFEI |
network_name_str |
Research, Society and Development |
repository_id_str |
|
spelling |
Union endurance of adhesive systems in humid dentin and dry dentin: integrative review Resitencia de la unión de los sistemas adhesivos en dentina húmeda y en dentina seca: revisión integradoraResistência de união dos sistemas adesivos em dentina úmida e em dentina seca: revisão integrativa DentinaProtocolos clínicosResistencia de la uniónSistemas adhesivos.DentinClinical protocolsUnion EnduranceAdhesive systems.DentinaProtocolos clínicosResistência de uniãoSistemas adesivos.Adhesion to dentin is difficult because it is a structure with high water composition, over the years the clinical protocols, as well as the adhesive systems have been changed, in order to improve the union endurance and simplify the technique. Through a integrative review, discuss the union endurance of adhesive systems in wet and dry dentin in order to improve clinical protocols. The selection of articles was carried out through the virtual health library (VHL), obtaining articles from the MEDLINE, LILACS, Biblioteca Brasileira de Odontologia (BBO) databases, in addition to searches on Google® Scholar, using the indexed terms: “Dentin”, “Dentina”, "Dentin-Bonding Agents" and “Adesivos dentinários”. Articles published between 2013 and 2020 were included. The selected studies could be clinical or laboratory, in wet and dry dentin, using tensile, microtensile or shear strength tests in the studies in vitro, with conventional, self-etching and / or universal adhesive systems, published as short articles, posters or literature reviews were excluded. 969 were found, 8 articles were selected according to the inclusion criteria, all studies addressed the degree dentin moisture content as a limiting factor in the quality of adhesion, as well as the operator's knowledge about the composition of the adhesive system used. Universal adhesive systems were effective on both wet and dry dentin, conventional adhesive systems were efficient only on wet dentin.La adherencia a la dentina es obstaculizada porque es una estructura con alta composición hídrica, a lo largo de los años los protocolos clínicos, así como los sistemas adhesivos han sido cambiados, con el objetivo de mejorar la resistencia de la unión y simplificar la técnica. Por medio de una revisión integradora, exponer sobre la resistencia de la unión de los sistemas adhesivos en dentina húmeda y en dentina seca com el objetivo de mejorar los protocolos clínicos. La selección de los artículo fue realizada a través de a biblioteca virtual en salud (BVS), consiguiendo artículos de las bases MEDLINE, LILACS, Biblioteca Brasileira de Odontologia (BBO), además de búsquedas en Google® Scholar, utilizando los términos indexados: “Dentin”, “Dentina”, "Dentin-Bonding Agents" e “Adesivos dentinários”. Han sido incluido artículos publicados entre 2013 y 2020. Los estudios seleccionados podrían ser clínicos o laboratoriales, en dentina húmeda y en dentina seca, utilizando testes de resistencia a la tracción, microtracción o cizallamiento en los estudios in vitro, com los sistemas adhesivos convencionales, autoacondicionantes y/o universales. Han sido excluídas publicaciones como artículos cortos, carteles o revisiones de literatura. Fueron encontrados 969, habiendo sido seleccionados 8 artículos según los criterios de inclusión, todos los estudios presentaron el grado de humedad de la dentina como un factor limitante en la calidad de adherencia, así como el conocimiento del operador respecto a de la composición del sistema adhesivo utilizado. Los sistemas adhesivos universales han sido efectivos tanto en dentina húmeda como en dentina seca, los sistemas adhesivos convencionales fueron eficientes sólo en dentina húmeda.A adesão à dentina é dificultada por se tratar de uma estrutura com alta composição hídrica, ao longo dos anos os protocolos clínicos, assim como os sistemas adesivos foram sendo alterados, visando melhorar a resistência de união e simplificar a técnica. Por meio de revisão integrativa, discorre-se aqui sobre a resistência de união dos sistemas adesivos em dentina úmida e em dentina seca visando sugerir melhorias dos protocolos clínicos. Selecionou-se os artigos através da biblioteca virtual em saúde (BVS), obtendo-os das bases MEDLINE, LILACS, Biblioteca Brasileira de Odontologia (BBO), além de buscas no Google® Scholar, usando os termos indexados: “Dentin”, “Dentina”, "Dentin-Bonding Agents" e “Adesivos dentinários”. Incluiu-se artigos publicados entre 2013 e 2020. Os estudos selecionados poderiam ser clínicos ou laboratoriais, em dentina úmida e em dentina seca, usando testes de resistência à tração, microtração ou cisalhamento nos estudos in vitro, com os sistemas adesivos convencionais, autocondicionantes e/ou universais. Foram excluídos artigos curtos, pôsteres ou revisões de literatura. Encontrou-se 969 artigos, sendo selecionados 8 deles, segundo os critérios de inclusão, todos os estudos abordavam o grau de umidade da dentina como um fator limitante na qualidade de adesão, assim como o conhecimento do operador a respeito da composição do sistema adesivo utilizado. Os sistemas adesivos universais foram eficazes tanto em dentina úmida quanto em dentina seca, já os sistemas adesivos convencionais foram eficientes apenas em dentina úmida.Research, Society and Development2021-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/1389410.33448/rsd-v10i4.13894Research, Society and Development; Vol. 10 No. 4; e10710413894Research, Society and Development; Vol. 10 Núm. 4; e10710413894Research, Society and Development; v. 10 n. 4; e107104138942525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIporhttps://rsdjournal.org/index.php/rsd/article/view/13894/12474Copyright (c) 2021 Hiully Karydja Câmara Oliveira; Isabela Pinheiro Cavalcanti Lima; Hugo Matheus Câmara Oliveira; Nara Grazieli Martins Lima; Talita da Silva Pinto; Matheus da Silva Regis; Heloísa Pereira de Medeiroshttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessOliveira, Hiully Karydja CâmaraLima, Isabela Pinheiro CavalcantiOliveira, Hugo Matheus CâmaraLima, Nara Grazieli MartinsPinto, Talita da SilvaRegis, Matheus da Silva Medeiros, Heloísa Pereira de2021-04-25T11:21:26Zoai:ojs.pkp.sfu.ca:article/13894Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:35:08.691094Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false |
dc.title.none.fl_str_mv |
Union endurance of adhesive systems in humid dentin and dry dentin: integrative review Resitencia de la unión de los sistemas adhesivos en dentina húmeda y en dentina seca: revisión integradora Resistência de união dos sistemas adesivos em dentina úmida e em dentina seca: revisão integrativa |
title |
Union endurance of adhesive systems in humid dentin and dry dentin: integrative review |
spellingShingle |
Union endurance of adhesive systems in humid dentin and dry dentin: integrative review Oliveira, Hiully Karydja Câmara Dentina Protocolos clínicos Resistencia de la unión Sistemas adhesivos. Dentin Clinical protocols Union Endurance Adhesive systems. Dentina Protocolos clínicos Resistência de união Sistemas adesivos. |
title_short |
Union endurance of adhesive systems in humid dentin and dry dentin: integrative review |
title_full |
Union endurance of adhesive systems in humid dentin and dry dentin: integrative review |
title_fullStr |
Union endurance of adhesive systems in humid dentin and dry dentin: integrative review |
title_full_unstemmed |
Union endurance of adhesive systems in humid dentin and dry dentin: integrative review |
title_sort |
Union endurance of adhesive systems in humid dentin and dry dentin: integrative review |
author |
Oliveira, Hiully Karydja Câmara |
author_facet |
Oliveira, Hiully Karydja Câmara Lima, Isabela Pinheiro Cavalcanti Oliveira, Hugo Matheus Câmara Lima, Nara Grazieli Martins Pinto, Talita da Silva Regis, Matheus da Silva Medeiros, Heloísa Pereira de |
author_role |
author |
author2 |
Lima, Isabela Pinheiro Cavalcanti Oliveira, Hugo Matheus Câmara Lima, Nara Grazieli Martins Pinto, Talita da Silva Regis, Matheus da Silva Medeiros, Heloísa Pereira de |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Oliveira, Hiully Karydja Câmara Lima, Isabela Pinheiro Cavalcanti Oliveira, Hugo Matheus Câmara Lima, Nara Grazieli Martins Pinto, Talita da Silva Regis, Matheus da Silva Medeiros, Heloísa Pereira de |
dc.subject.por.fl_str_mv |
Dentina Protocolos clínicos Resistencia de la unión Sistemas adhesivos. Dentin Clinical protocols Union Endurance Adhesive systems. Dentina Protocolos clínicos Resistência de união Sistemas adesivos. |
topic |
Dentina Protocolos clínicos Resistencia de la unión Sistemas adhesivos. Dentin Clinical protocols Union Endurance Adhesive systems. Dentina Protocolos clínicos Resistência de união Sistemas adesivos. |
description |
Adhesion to dentin is difficult because it is a structure with high water composition, over the years the clinical protocols, as well as the adhesive systems have been changed, in order to improve the union endurance and simplify the technique. Through a integrative review, discuss the union endurance of adhesive systems in wet and dry dentin in order to improve clinical protocols. The selection of articles was carried out through the virtual health library (VHL), obtaining articles from the MEDLINE, LILACS, Biblioteca Brasileira de Odontologia (BBO) databases, in addition to searches on Google® Scholar, using the indexed terms: “Dentin”, “Dentina”, "Dentin-Bonding Agents" and “Adesivos dentinários”. Articles published between 2013 and 2020 were included. The selected studies could be clinical or laboratory, in wet and dry dentin, using tensile, microtensile or shear strength tests in the studies in vitro, with conventional, self-etching and / or universal adhesive systems, published as short articles, posters or literature reviews were excluded. 969 were found, 8 articles were selected according to the inclusion criteria, all studies addressed the degree dentin moisture content as a limiting factor in the quality of adhesion, as well as the operator's knowledge about the composition of the adhesive system used. Universal adhesive systems were effective on both wet and dry dentin, conventional adhesive systems were efficient only on wet dentin. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://rsdjournal.org/index.php/rsd/article/view/13894 10.33448/rsd-v10i4.13894 |
url |
https://rsdjournal.org/index.php/rsd/article/view/13894 |
identifier_str_mv |
10.33448/rsd-v10i4.13894 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://rsdjournal.org/index.php/rsd/article/view/13894/12474 |
dc.rights.driver.fl_str_mv |
https://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Research, Society and Development |
publisher.none.fl_str_mv |
Research, Society and Development |
dc.source.none.fl_str_mv |
Research, Society and Development; Vol. 10 No. 4; e10710413894 Research, Society and Development; Vol. 10 Núm. 4; e10710413894 Research, Society and Development; v. 10 n. 4; e10710413894 2525-3409 reponame:Research, Society and Development instname:Universidade Federal de Itajubá (UNIFEI) instacron:UNIFEI |
instname_str |
Universidade Federal de Itajubá (UNIFEI) |
instacron_str |
UNIFEI |
institution |
UNIFEI |
reponame_str |
Research, Society and Development |
collection |
Research, Society and Development |
repository.name.fl_str_mv |
Research, Society and Development - Universidade Federal de Itajubá (UNIFEI) |
repository.mail.fl_str_mv |
rsd.articles@gmail.com |
_version_ |
1797052747224186880 |