Pode a seleção da técnica ser superior ao material escolhido para a união de transferentes?

Detalhes bibliográficos
Autor(a) principal: Mariotto, Guilherme de Aguiar
Data de Publicação: 2018
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações do UNIOESTE
Texto Completo: http://tede.unioeste.br/handle/tede/4144
Resumo: STATEMANT OF PROBLEM: The splint transfer technique in implant impression can result in misfit on prosthetic structures. PURPOSE: To evaluate the linear dimensional change of polymerization from 3 materials and 2 techniques of splint transfer technique for implant prostheses used in the open tray technique. MATERIAL AND METHODS: Two implants were installed in a nylon mastermodel whith the shape of a upperjaw, over this two implants, miruscone were tapered. Open tray transfer impression coppings were coupled in to the miruscone, and a silicone guide was made standardizing the unions between the transfers. The samples were divided in six groups (n=20): autopolymerizing acrylic resin Pattern Resin (PA) and Durallay (DU), and bis-acrylic resin Protemp4 (BI), with single step and sectioning and bonding segments techniques (PAC, DUC, BIC). The values of linear dimensional change between these transfers were measured in a profile projector (VB300; Starret) coupled to the Quadra Check apparatus, with a measurement capacity of 0.001 mm, performed by a calibrated single operator. Data were submitted to factorial ANOVA, two-way: Materials and technique (p <0.01) RESULTS: Statistically significant results were found in all comparisons. The PA resin presented the smallest values (μm) of linear dimensional change, both in the single-step technique and in the section and conding, in the following order: BI 255.73(+3.81), DU 173.75(+2.30), PA 95.97(+3.20), BIC 23.82(+1.71), DUC 20.85(+2.53), PAC 13.27(+2.09). The single-step technique obtained worse results regardless of the material. CONCLUSIONS: The sectioning and bonding technique reduced the dimensional change of the samples in all materials, and the Pattern Resin LS presented the lowest contraction, followed by Durallay and Protemp4. CLINICAL IMPLICATIONS: For the transfer splintage in implant prothesis the choice of technique seems to be more importante than the selection of the material to get fidelity of the models
id UNIOESTE-1_0b453824d27b89340fb2f6dfb6741825
oai_identifier_str oai:tede.unioeste.br:tede/4144
network_acronym_str UNIOESTE-1
network_name_str Biblioteca Digital de Teses e Dissertações do UNIOESTE
repository_id_str
spelling Mendonça , Marcio Joséhttp://lattes.cnpq.br/7797504639182284Mendonça , Marcio Joséhttp://lattes.cnpq.br/7797504639182284Pinelli , Ligia Antunes Pereirahttp://lattes.cnpq.br/0455968557454133Delben , Juliana Aparecidahttp://lattes.cnpq.br/9415104528734148http://lattes.cnpq.br/5216397627615002Mariotto, Guilherme de Aguiar2019-03-12T21:59:27Z2018-03-27MARIOTTO, Guilherme de Aguiar. Pode a seleção da técnica ser superior ao material escolhido para a união de transferentes?. 2018. 48 f. Dissertação( Mestrado em Odontologia) - Universidade Estadual do Oeste do Paraná, Cascavel, 2018.http://tede.unioeste.br/handle/tede/4144STATEMANT OF PROBLEM: The splint transfer technique in implant impression can result in misfit on prosthetic structures. PURPOSE: To evaluate the linear dimensional change of polymerization from 3 materials and 2 techniques of splint transfer technique for implant prostheses used in the open tray technique. MATERIAL AND METHODS: Two implants were installed in a nylon mastermodel whith the shape of a upperjaw, over this two implants, miruscone were tapered. Open tray transfer impression coppings were coupled in to the miruscone, and a silicone guide was made standardizing the unions between the transfers. The samples were divided in six groups (n=20): autopolymerizing acrylic resin Pattern Resin (PA) and Durallay (DU), and bis-acrylic resin Protemp4 (BI), with single step and sectioning and bonding segments techniques (PAC, DUC, BIC). The values of linear dimensional change between these transfers were measured in a profile projector (VB300; Starret) coupled to the Quadra Check apparatus, with a measurement capacity of 0.001 mm, performed by a calibrated single operator. Data were submitted to factorial ANOVA, two-way: Materials and technique (p <0.01) RESULTS: Statistically significant results were found in all comparisons. The PA resin presented the smallest values (μm) of linear dimensional change, both in the single-step technique and in the section and conding, in the following order: BI 255.73(+3.81), DU 173.75(+2.30), PA 95.97(+3.20), BIC 23.82(+1.71), DUC 20.85(+2.53), PAC 13.27(+2.09). The single-step technique obtained worse results regardless of the material. CONCLUSIONS: The sectioning and bonding technique reduced the dimensional change of the samples in all materials, and the Pattern Resin LS presented the lowest contraction, followed by Durallay and Protemp4. CLINICAL IMPLICATIONS: For the transfer splintage in implant prothesis the choice of technique seems to be more importante than the selection of the material to get fidelity of the modelsDECLARAÇÃO DO PROBLEMA: A técnica de união entre os transferentes de moldagem para próteses sobre implantes pode resultar em desadaptações nas infraestruturas protéticas. OBJETIVOS: Avaliar a alteração dimensional linear de polimerização de 3 materiais e 2 técnicas de união de transferentes de moldagem para próteses sobre implantes utilizados na técnica da moldeira aberta. MATERIAL E MÉTODOS: Foi confeccionada uma matriz em forma de maxila em nylon, instalados dois implantes osseointegráveis e, sobre esses dois, minipilares cônicos retos. Transferentes de moldagem de moldeira aberta foram acoplados aos minipilares, e uma guia de silicone foi confeccionada padronizando as uniões entre transferentes. As amostras foram divididas em seis grupos (n=20): resinas acrílicas quimicoativadas Pattern Resin (PA) e Durallay (DU), e resina bisacrílica Protemp4 (BI), com as técnicas passo único e secção e união dos segmentos (PAC, DUC, BIC). Os valores de alteração dimensional linear ocorridos entre esses transferentes foram mensurados em projetor de perfil (VB300; Starret) acoplado ao aparelho Quadra Check, com capacidade de mensuração de 0.001 mm, realizado por único operador calibrado. Os dados foram submetidos ao teste de ANOVA fatorial, two-way: Materiais e técnica (p<0,01). RESULTADOS: Foram encontrados resultados estatisticamente significantes em todas as comparações. A resina PA apresentou os menores valores (μm) de alteração dimensional linear, tanto na técnica de passo único, quanto na técnica de secção e união, na seguinte ordem: BI 255.73(+3.81), DU 173.75(+2.30), PA 95.97(+3.20), BIC 23.82(+1.71), DUC 20.85(+2.53), PAC 13.27(+2.09). A técnica de passo único obteve piores resultados independente do material. CONCLUSÕES: A técnica de secção e união reduziu a alteração dimensional das amostras em todos os materiais, e a resina Pattern Resin LS apresentou a menor contração, seguida pela Durallay e Protemp4. IMPLICAÇÕES CLÍNICAS: Para a união de transferentes em próteses sobre implantes a escolha da técnica de união parece ser mais importante do que a seleção do material para a obtenção de maior fidelidade dos modelos.Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2019-03-12T21:59:27Z No. of bitstreams: 2 Guilherme_Mariotto_2018.pdf: 1557188 bytes, checksum: a9d67c335a6fbbe03d061239156c3baf (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)Made available in DSpace on 2019-03-12T21:59:27Z (GMT). No. of bitstreams: 2 Guilherme_Mariotto_2018.pdf: 1557188 bytes, checksum: a9d67c335a6fbbe03d061239156c3baf (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-03-27application/pdfpor6588633818200016417500Universidade Estadual do Oeste do ParanáCascavelPrograma de Pós-Graduação em OdontologiaUNIOESTEBrasilCentro de Ciências Biológicas e da Saúdehttp://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessImplantes DentáriosMoldagemTécnica de moldagem odontológicaDental implantsImpressionTechniqueCIENCIAS DA SAUDE::ODONTOLOGIAPode a seleção da técnica ser superior ao material escolhido para a união de transferentes?Can the selection of the technique be superior to the material selected for the splint of transferents?info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis-80965548187336651646006006001458059979463924370-2070498469879244349reponame:Biblioteca Digital de Teses e Dissertações do UNIOESTEinstname:Universidade Estadual do Oeste do Paraná (UNIOESTE)instacron:UNIOESTEORIGINALGuilherme_Mariotto_2018.pdfGuilherme_Mariotto_2018.pdfapplication/pdf1557188http://tede.unioeste.br:8080/tede/bitstream/tede/4144/5/Guilherme_Mariotto_2018.pdfa9d67c335a6fbbe03d061239156c3bafMD55CC-LICENSElicense_urllicense_urltext/plain; charset=utf-843http://tede.unioeste.br:8080/tede/bitstream/tede/4144/2/license_url321f3992dd3875151d8801b773ab32edMD52license_textlicense_texttext/html; charset=utf-80http://tede.unioeste.br:8080/tede/bitstream/tede/4144/3/license_textd41d8cd98f00b204e9800998ecf8427eMD53license_rdflicense_rdfapplication/rdf+xml; charset=utf-80http://tede.unioeste.br:8080/tede/bitstream/tede/4144/4/license_rdfd41d8cd98f00b204e9800998ecf8427eMD54LICENSElicense.txtlicense.txttext/plain; charset=utf-82165http://tede.unioeste.br:8080/tede/bitstream/tede/4144/1/license.txtbd3efa91386c1718a7f26a329fdcb468MD51tede/41442019-03-12 18:59:27.253oai:tede.unioeste.br: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Biblioteca Digital de Teses e Dissertaçõeshttp://tede.unioeste.br/PUBhttp://tede.unioeste.br/oai/requestbiblioteca.repositorio@unioeste.bropendoar:2019-03-12T21:59:27Biblioteca Digital de Teses e Dissertações do UNIOESTE - Universidade Estadual do Oeste do Paraná (UNIOESTE)false
dc.title.por.fl_str_mv Pode a seleção da técnica ser superior ao material escolhido para a união de transferentes?
dc.title.alternative.eng.fl_str_mv Can the selection of the technique be superior to the material selected for the splint of transferents?
title Pode a seleção da técnica ser superior ao material escolhido para a união de transferentes?
spellingShingle Pode a seleção da técnica ser superior ao material escolhido para a união de transferentes?
Mariotto, Guilherme de Aguiar
Implantes Dentários
Moldagem
Técnica de moldagem odontológica
Dental implants
Impression
Technique
CIENCIAS DA SAUDE::ODONTOLOGIA
title_short Pode a seleção da técnica ser superior ao material escolhido para a união de transferentes?
title_full Pode a seleção da técnica ser superior ao material escolhido para a união de transferentes?
title_fullStr Pode a seleção da técnica ser superior ao material escolhido para a união de transferentes?
title_full_unstemmed Pode a seleção da técnica ser superior ao material escolhido para a união de transferentes?
title_sort Pode a seleção da técnica ser superior ao material escolhido para a união de transferentes?
author Mariotto, Guilherme de Aguiar
author_facet Mariotto, Guilherme de Aguiar
author_role author
dc.contributor.advisor1.fl_str_mv Mendonça , Marcio José
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/7797504639182284
dc.contributor.referee1.fl_str_mv Mendonça , Marcio José
dc.contributor.referee1Lattes.fl_str_mv http://lattes.cnpq.br/7797504639182284
dc.contributor.referee2.fl_str_mv Pinelli , Ligia Antunes Pereira
dc.contributor.referee2Lattes.fl_str_mv http://lattes.cnpq.br/0455968557454133
dc.contributor.referee3.fl_str_mv Delben , Juliana Aparecida
dc.contributor.referee3Lattes.fl_str_mv http://lattes.cnpq.br/9415104528734148
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/5216397627615002
dc.contributor.author.fl_str_mv Mariotto, Guilherme de Aguiar
contributor_str_mv Mendonça , Marcio José
Mendonça , Marcio José
Pinelli , Ligia Antunes Pereira
Delben , Juliana Aparecida
dc.subject.por.fl_str_mv Implantes Dentários
Moldagem
Técnica de moldagem odontológica
topic Implantes Dentários
Moldagem
Técnica de moldagem odontológica
Dental implants
Impression
Technique
CIENCIAS DA SAUDE::ODONTOLOGIA
dc.subject.eng.fl_str_mv Dental implants
Impression
Technique
dc.subject.cnpq.fl_str_mv CIENCIAS DA SAUDE::ODONTOLOGIA
description STATEMANT OF PROBLEM: The splint transfer technique in implant impression can result in misfit on prosthetic structures. PURPOSE: To evaluate the linear dimensional change of polymerization from 3 materials and 2 techniques of splint transfer technique for implant prostheses used in the open tray technique. MATERIAL AND METHODS: Two implants were installed in a nylon mastermodel whith the shape of a upperjaw, over this two implants, miruscone were tapered. Open tray transfer impression coppings were coupled in to the miruscone, and a silicone guide was made standardizing the unions between the transfers. The samples were divided in six groups (n=20): autopolymerizing acrylic resin Pattern Resin (PA) and Durallay (DU), and bis-acrylic resin Protemp4 (BI), with single step and sectioning and bonding segments techniques (PAC, DUC, BIC). The values of linear dimensional change between these transfers were measured in a profile projector (VB300; Starret) coupled to the Quadra Check apparatus, with a measurement capacity of 0.001 mm, performed by a calibrated single operator. Data were submitted to factorial ANOVA, two-way: Materials and technique (p <0.01) RESULTS: Statistically significant results were found in all comparisons. The PA resin presented the smallest values (μm) of linear dimensional change, both in the single-step technique and in the section and conding, in the following order: BI 255.73(+3.81), DU 173.75(+2.30), PA 95.97(+3.20), BIC 23.82(+1.71), DUC 20.85(+2.53), PAC 13.27(+2.09). The single-step technique obtained worse results regardless of the material. CONCLUSIONS: The sectioning and bonding technique reduced the dimensional change of the samples in all materials, and the Pattern Resin LS presented the lowest contraction, followed by Durallay and Protemp4. CLINICAL IMPLICATIONS: For the transfer splintage in implant prothesis the choice of technique seems to be more importante than the selection of the material to get fidelity of the models
publishDate 2018
dc.date.issued.fl_str_mv 2018-03-27
dc.date.accessioned.fl_str_mv 2019-03-12T21:59:27Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv MARIOTTO, Guilherme de Aguiar. Pode a seleção da técnica ser superior ao material escolhido para a união de transferentes?. 2018. 48 f. Dissertação( Mestrado em Odontologia) - Universidade Estadual do Oeste do Paraná, Cascavel, 2018.
dc.identifier.uri.fl_str_mv http://tede.unioeste.br/handle/tede/4144
identifier_str_mv MARIOTTO, Guilherme de Aguiar. Pode a seleção da técnica ser superior ao material escolhido para a união de transferentes?. 2018. 48 f. Dissertação( Mestrado em Odontologia) - Universidade Estadual do Oeste do Paraná, Cascavel, 2018.
url http://tede.unioeste.br/handle/tede/4144
dc.language.iso.fl_str_mv por
language por
dc.relation.program.fl_str_mv -8096554818733665164
dc.relation.confidence.fl_str_mv 600
600
600
dc.relation.department.fl_str_mv 1458059979463924370
dc.relation.cnpq.fl_str_mv -2070498469879244349
dc.rights.driver.fl_str_mv http://creativecommons.org/licenses/by/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Estadual do Oeste do Paraná
Cascavel
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Odontologia
dc.publisher.initials.fl_str_mv UNIOESTE
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Centro de Ciências Biológicas e da Saúde
publisher.none.fl_str_mv Universidade Estadual do Oeste do Paraná
Cascavel
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações do UNIOESTE
instname:Universidade Estadual do Oeste do Paraná (UNIOESTE)
instacron:UNIOESTE
instname_str Universidade Estadual do Oeste do Paraná (UNIOESTE)
instacron_str UNIOESTE
institution UNIOESTE
reponame_str Biblioteca Digital de Teses e Dissertações do UNIOESTE
collection Biblioteca Digital de Teses e Dissertações do UNIOESTE
bitstream.url.fl_str_mv http://tede.unioeste.br:8080/tede/bitstream/tede/4144/5/Guilherme_Mariotto_2018.pdf
http://tede.unioeste.br:8080/tede/bitstream/tede/4144/2/license_url
http://tede.unioeste.br:8080/tede/bitstream/tede/4144/3/license_text
http://tede.unioeste.br:8080/tede/bitstream/tede/4144/4/license_rdf
http://tede.unioeste.br:8080/tede/bitstream/tede/4144/1/license.txt
bitstream.checksum.fl_str_mv a9d67c335a6fbbe03d061239156c3baf
321f3992dd3875151d8801b773ab32ed
d41d8cd98f00b204e9800998ecf8427e
d41d8cd98f00b204e9800998ecf8427e
bd3efa91386c1718a7f26a329fdcb468
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações do UNIOESTE - Universidade Estadual do Oeste do Paraná (UNIOESTE)
repository.mail.fl_str_mv biblioteca.repositorio@unioeste.br
_version_ 1801124557259538432