Avaliação e comparação da eficiência de painéis fotovoltaicos instalados na Unioeste, campus de Cascavel (PR), considerando diferentes inclinações e níveis de sujidade
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Biblioteca Digital de Teses e Dissertações do UNIOESTE |
Texto Completo: | http://tede.unioeste.br/handle/tede/5383 |
Resumo: | This research aimed to verify the influence of dirt and inclination of the panels of a photovoltaic solar system connected to the grid, installed at the State University of Western Paraná - UNIOESTE, Cascavel – PR campus. The system consists of ten photovoltaic modules of 330 Wp each (two panels with five modules in series), and an inverter of 4 kWp. At first, the two panels were cleaned (both facing north, with an inclination of 21º in relation to the horizontal plane), and for a period of nine weeks, only panel 1 was washed weekly, while the panel 2 was kept in ambient conditions, without any cleaning. After the collection of this data, both panels were washed again, and the inclination of panel 1 was changed to 26º, and then maintained equal for nine weeks. After this period, the inclination of panel 1 was changed to 16º, and maintained again for nine weeks. In both analyzes, the data collected from generation of panel 2, which was not washed weekly and remained at its original inclination of 21º, were used as a reference. Subsequently, the Analysis of Variance test (ANOVA) was applied to the average of the daily efficiencies of the panels. It was possible to conclude that there was a significant difference in the module washing experiment and also in the case study in which panel 1 was kept at 21º and panel 2 at 18º. Furthermore, the result of the Tukey test shows that the averages in the two cases mentioned above are different from each other. However, there was no difference when comparing the efficiency averages between the angles of 21º and 26º in the analyzed period. |
id |
UNIOESTE-1_b11bef88166a3e3517a33cc5ef42f3a1 |
---|---|
oai_identifier_str |
oai:tede.unioeste.br:tede/5383 |
network_acronym_str |
UNIOESTE-1 |
network_name_str |
Biblioteca Digital de Teses e Dissertações do UNIOESTE |
repository_id_str |
|
spelling |
Nogueira, Carlos Eduardo Camargohttp://lattes.cnpq.br/7250468059476566Siqueira, Jair Antonio Cruzhttp://lattes.cnpq.br/5644626331586827Nogueira, Carlos Eduardo Camargohttp://lattes.cnpq.br/7250468059476566Prior, Maritanehttp://lattes.cnpq.br/4825760115389832Santos, José Airton Azevedo doshttp://lattes.cnpq.br/1208427854093144http://lattes.cnpq.br/3986192818274000Foltz, Laura Luana2021-05-20T13:05:04Z2021-02-22FOLTZ, Laura Luana. Avaliação e comparação da eficiência de painéis fotovoltaicos instalados na Unioeste, campus de Cascavel (PR), considerando diferentes inclinações e níveis de sujidade. 2021. 77 f. Dissertação (Mestrado em Engenharia de Energia na Agricultura) - Universidade Estadual do Oeste do Paraná, Cascavel - PR.http://tede.unioeste.br/handle/tede/5383This research aimed to verify the influence of dirt and inclination of the panels of a photovoltaic solar system connected to the grid, installed at the State University of Western Paraná - UNIOESTE, Cascavel – PR campus. The system consists of ten photovoltaic modules of 330 Wp each (two panels with five modules in series), and an inverter of 4 kWp. At first, the two panels were cleaned (both facing north, with an inclination of 21º in relation to the horizontal plane), and for a period of nine weeks, only panel 1 was washed weekly, while the panel 2 was kept in ambient conditions, without any cleaning. After the collection of this data, both panels were washed again, and the inclination of panel 1 was changed to 26º, and then maintained equal for nine weeks. After this period, the inclination of panel 1 was changed to 16º, and maintained again for nine weeks. In both analyzes, the data collected from generation of panel 2, which was not washed weekly and remained at its original inclination of 21º, were used as a reference. Subsequently, the Analysis of Variance test (ANOVA) was applied to the average of the daily efficiencies of the panels. It was possible to conclude that there was a significant difference in the module washing experiment and also in the case study in which panel 1 was kept at 21º and panel 2 at 18º. Furthermore, the result of the Tukey test shows that the averages in the two cases mentioned above are different from each other. However, there was no difference when comparing the efficiency averages between the angles of 21º and 26º in the analyzed period.Este trabalho tem por objetivo verificar a influência da sujidade e da inclinação dos painéis de um sistema solar fotovoltaico conectado à rede, instalados na Universidade Estadual do Oeste do Paraná – UNIOESTE, campus de Cascavel – PR. O sistema é composto por dez módulos fotovoltaicos de 330 Wp cada (dois painéis com cinco módulos em série), e um inversor de 4 kWp. Em um primeiro instante, foi realizada a limpeza dos dois painéis (ambos voltados para o norte, com uma inclinação de 21º em relação ao plano horizontal), e durante um período de nove semanas, apenas o painel 1 foi lavado semanalmente, enquanto o painel 2 foi mantido nas condições ambientais, sem nenhuma limpeza. Depois da coleta desses dados, ambos os painéis foram lavados novamente, e a inclinação do painel 1 foi alterada para 26º, sendo mantida assim por sete semanas e três dias. Após esse período, a inclinação do painel 1 foi alterada para 18º, e mantida novamente por oito semanas. Nas duas análises, os dados coletados de geração do painel 2, que não foi lavado semanalmente e permaneceu em sua inclinação original de 21º, foram utilizados como referência. Posteriormente, foi aplicado o teste da Análise de Variância (ANOVA) na média das eficiências diárias dos painéis. Foi possível concluir que houve diferença significativa no experimento da lavagem dos módulos e também no estudo de caso em que o painel 1 foi mantido em 21º e o painel 2 em 18º. Ainda, o resultado do teste Tukey apresentou que as médias nos dois casos citados acima são diferentes entre si. No entanto, não houve diferença significativa quando comparadas às médias de eficiência entre os ângulos de 21º e 26º no período analisado.Submitted by Neusa Fagundes (neusa.fagundes@unioeste.br) on 2021-05-20T13:05:04Z No. of bitstreams: 2 Laura_Foltz2021.pdf: 1744606 bytes, checksum: 1b426c4225164ac29c1ef67f28acf183 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)Made available in DSpace on 2021-05-20T13:05:04Z (GMT). No. of bitstreams: 2 Laura_Foltz2021.pdf: 1744606 bytes, checksum: 1b426c4225164ac29c1ef67f28acf183 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2021-02-22application/pdfpor6588633818200016417500Universidade Estadual do Oeste do ParanáCascavelPrograma de Pós-Graduação em Engenharia de Energia na AgriculturaUNIOESTEBrasilCentro de Ciências Exatas e Tecnológicashttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessSistema Solar FotovoltaicoSujidade dos painéisInclinação dos painéisPhotovoltaic Solar SystemDirt from the panelsSlope of the panelsAgroenergiaAvaliação e comparação da eficiência de painéis fotovoltaicos instalados na Unioeste, campus de Cascavel (PR), considerando diferentes inclinações e níveis de sujidadeEvaluation and comparison of efficiency of two photovoltaic panels installed in Unioeste, campus of Cascavel (PR), considering different slopes and levels of dirtinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis22899580898209547416006002214374442868382015reponame:Biblioteca Digital de Teses e Dissertações do UNIOESTEinstname:Universidade Estadual do Oeste do Paraná (UNIOESTE)instacron:UNIOESTEORIGINALLaura_Foltz2021.pdfLaura_Foltz2021.pdfapplication/pdf1744606http://tede.unioeste.br:8080/tede/bitstream/tede/5383/5/Laura_Foltz2021.pdf1b426c4225164ac29c1ef67f28acf183MD55CC-LICENSElicense_urllicense_urltext/plain; charset=utf-849http://tede.unioeste.br:8080/tede/bitstream/tede/5383/2/license_url4afdbb8c545fd630ea7db775da747b2fMD52license_textlicense_texttext/html; charset=utf-80http://tede.unioeste.br:8080/tede/bitstream/tede/5383/3/license_textd41d8cd98f00b204e9800998ecf8427eMD53license_rdflicense_rdfapplication/rdf+xml; charset=utf-80http://tede.unioeste.br:8080/tede/bitstream/tede/5383/4/license_rdfd41d8cd98f00b204e9800998ecf8427eMD54LICENSElicense.txtlicense.txttext/plain; charset=utf-82165http://tede.unioeste.br:8080/tede/bitstream/tede/5383/1/license.txtbd3efa91386c1718a7f26a329fdcb468MD51tede/53832021-05-20 10:05:04.69oai:tede.unioeste.br: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Biblioteca Digital de Teses e Dissertaçõeshttp://tede.unioeste.br/PUBhttp://tede.unioeste.br/oai/requestbiblioteca.repositorio@unioeste.bropendoar:2021-05-20T13:05:04Biblioteca Digital de Teses e Dissertações do UNIOESTE - Universidade Estadual do Oeste do Paraná (UNIOESTE)false |
dc.title.por.fl_str_mv |
Avaliação e comparação da eficiência de painéis fotovoltaicos instalados na Unioeste, campus de Cascavel (PR), considerando diferentes inclinações e níveis de sujidade |
dc.title.alternative.eng.fl_str_mv |
Evaluation and comparison of efficiency of two photovoltaic panels installed in Unioeste, campus of Cascavel (PR), considering different slopes and levels of dirt |
title |
Avaliação e comparação da eficiência de painéis fotovoltaicos instalados na Unioeste, campus de Cascavel (PR), considerando diferentes inclinações e níveis de sujidade |
spellingShingle |
Avaliação e comparação da eficiência de painéis fotovoltaicos instalados na Unioeste, campus de Cascavel (PR), considerando diferentes inclinações e níveis de sujidade Foltz, Laura Luana Sistema Solar Fotovoltaico Sujidade dos painéis Inclinação dos painéis Photovoltaic Solar System Dirt from the panels Slope of the panels Agroenergia |
title_short |
Avaliação e comparação da eficiência de painéis fotovoltaicos instalados na Unioeste, campus de Cascavel (PR), considerando diferentes inclinações e níveis de sujidade |
title_full |
Avaliação e comparação da eficiência de painéis fotovoltaicos instalados na Unioeste, campus de Cascavel (PR), considerando diferentes inclinações e níveis de sujidade |
title_fullStr |
Avaliação e comparação da eficiência de painéis fotovoltaicos instalados na Unioeste, campus de Cascavel (PR), considerando diferentes inclinações e níveis de sujidade |
title_full_unstemmed |
Avaliação e comparação da eficiência de painéis fotovoltaicos instalados na Unioeste, campus de Cascavel (PR), considerando diferentes inclinações e níveis de sujidade |
title_sort |
Avaliação e comparação da eficiência de painéis fotovoltaicos instalados na Unioeste, campus de Cascavel (PR), considerando diferentes inclinações e níveis de sujidade |
author |
Foltz, Laura Luana |
author_facet |
Foltz, Laura Luana |
author_role |
author |
dc.contributor.advisor1.fl_str_mv |
Nogueira, Carlos Eduardo Camargo |
dc.contributor.advisor1Lattes.fl_str_mv |
http://lattes.cnpq.br/7250468059476566 |
dc.contributor.advisor-co1.fl_str_mv |
Siqueira, Jair Antonio Cruz |
dc.contributor.advisor-co1Lattes.fl_str_mv |
http://lattes.cnpq.br/5644626331586827 |
dc.contributor.referee1.fl_str_mv |
Nogueira, Carlos Eduardo Camargo |
dc.contributor.referee1Lattes.fl_str_mv |
http://lattes.cnpq.br/7250468059476566 |
dc.contributor.referee2.fl_str_mv |
Prior, Maritane |
dc.contributor.referee2Lattes.fl_str_mv |
http://lattes.cnpq.br/4825760115389832 |
dc.contributor.referee3.fl_str_mv |
Santos, José Airton Azevedo dos |
dc.contributor.referee3Lattes.fl_str_mv |
http://lattes.cnpq.br/1208427854093144 |
dc.contributor.authorLattes.fl_str_mv |
http://lattes.cnpq.br/3986192818274000 |
dc.contributor.author.fl_str_mv |
Foltz, Laura Luana |
contributor_str_mv |
Nogueira, Carlos Eduardo Camargo Siqueira, Jair Antonio Cruz Nogueira, Carlos Eduardo Camargo Prior, Maritane Santos, José Airton Azevedo dos |
dc.subject.por.fl_str_mv |
Sistema Solar Fotovoltaico Sujidade dos painéis Inclinação dos painéis |
topic |
Sistema Solar Fotovoltaico Sujidade dos painéis Inclinação dos painéis Photovoltaic Solar System Dirt from the panels Slope of the panels Agroenergia |
dc.subject.eng.fl_str_mv |
Photovoltaic Solar System Dirt from the panels Slope of the panels |
dc.subject.cnpq.fl_str_mv |
Agroenergia |
description |
This research aimed to verify the influence of dirt and inclination of the panels of a photovoltaic solar system connected to the grid, installed at the State University of Western Paraná - UNIOESTE, Cascavel – PR campus. The system consists of ten photovoltaic modules of 330 Wp each (two panels with five modules in series), and an inverter of 4 kWp. At first, the two panels were cleaned (both facing north, with an inclination of 21º in relation to the horizontal plane), and for a period of nine weeks, only panel 1 was washed weekly, while the panel 2 was kept in ambient conditions, without any cleaning. After the collection of this data, both panels were washed again, and the inclination of panel 1 was changed to 26º, and then maintained equal for nine weeks. After this period, the inclination of panel 1 was changed to 16º, and maintained again for nine weeks. In both analyzes, the data collected from generation of panel 2, which was not washed weekly and remained at its original inclination of 21º, were used as a reference. Subsequently, the Analysis of Variance test (ANOVA) was applied to the average of the daily efficiencies of the panels. It was possible to conclude that there was a significant difference in the module washing experiment and also in the case study in which panel 1 was kept at 21º and panel 2 at 18º. Furthermore, the result of the Tukey test shows that the averages in the two cases mentioned above are different from each other. However, there was no difference when comparing the efficiency averages between the angles of 21º and 26º in the analyzed period. |
publishDate |
2021 |
dc.date.accessioned.fl_str_mv |
2021-05-20T13:05:04Z |
dc.date.issued.fl_str_mv |
2021-02-22 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
FOLTZ, Laura Luana. Avaliação e comparação da eficiência de painéis fotovoltaicos instalados na Unioeste, campus de Cascavel (PR), considerando diferentes inclinações e níveis de sujidade. 2021. 77 f. Dissertação (Mestrado em Engenharia de Energia na Agricultura) - Universidade Estadual do Oeste do Paraná, Cascavel - PR. |
dc.identifier.uri.fl_str_mv |
http://tede.unioeste.br/handle/tede/5383 |
identifier_str_mv |
FOLTZ, Laura Luana. Avaliação e comparação da eficiência de painéis fotovoltaicos instalados na Unioeste, campus de Cascavel (PR), considerando diferentes inclinações e níveis de sujidade. 2021. 77 f. Dissertação (Mestrado em Engenharia de Energia na Agricultura) - Universidade Estadual do Oeste do Paraná, Cascavel - PR. |
url |
http://tede.unioeste.br/handle/tede/5383 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.program.fl_str_mv |
2289958089820954741 |
dc.relation.confidence.fl_str_mv |
600 600 |
dc.relation.department.fl_str_mv |
2214374442868382015 |
dc.rights.driver.fl_str_mv |
http://creativecommons.org/licenses/by-nc-nd/4.0/ info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/4.0/ |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Estadual do Oeste do Paraná Cascavel |
dc.publisher.program.fl_str_mv |
Programa de Pós-Graduação em Engenharia de Energia na Agricultura |
dc.publisher.initials.fl_str_mv |
UNIOESTE |
dc.publisher.country.fl_str_mv |
Brasil |
dc.publisher.department.fl_str_mv |
Centro de Ciências Exatas e Tecnológicas |
publisher.none.fl_str_mv |
Universidade Estadual do Oeste do Paraná Cascavel |
dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Teses e Dissertações do UNIOESTE instname:Universidade Estadual do Oeste do Paraná (UNIOESTE) instacron:UNIOESTE |
instname_str |
Universidade Estadual do Oeste do Paraná (UNIOESTE) |
instacron_str |
UNIOESTE |
institution |
UNIOESTE |
reponame_str |
Biblioteca Digital de Teses e Dissertações do UNIOESTE |
collection |
Biblioteca Digital de Teses e Dissertações do UNIOESTE |
bitstream.url.fl_str_mv |
http://tede.unioeste.br:8080/tede/bitstream/tede/5383/5/Laura_Foltz2021.pdf http://tede.unioeste.br:8080/tede/bitstream/tede/5383/2/license_url http://tede.unioeste.br:8080/tede/bitstream/tede/5383/3/license_text http://tede.unioeste.br:8080/tede/bitstream/tede/5383/4/license_rdf http://tede.unioeste.br:8080/tede/bitstream/tede/5383/1/license.txt |
bitstream.checksum.fl_str_mv |
1b426c4225164ac29c1ef67f28acf183 4afdbb8c545fd630ea7db775da747b2f d41d8cd98f00b204e9800998ecf8427e d41d8cd98f00b204e9800998ecf8427e bd3efa91386c1718a7f26a329fdcb468 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Biblioteca Digital de Teses e Dissertações do UNIOESTE - Universidade Estadual do Oeste do Paraná (UNIOESTE) |
repository.mail.fl_str_mv |
biblioteca.repositorio@unioeste.br |
_version_ |
1811723440683483136 |