A steep peripheral ring in irregular cornea topography, real or an instrument error?
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
DOI: | 10.1016/j.sjopt.2016.04.002 |
Texto Completo: | http://dx.doi.org/10.1016/j.sjopt.2016.04.002 http://hdl.handle.net/11449/173711 |
Resumo: | Purpose To demonstrate that the steep peripheral ring (red zone) on corneal topography after myopic laser in situ keratomileusis (LASIK) could possibly due to instrument error and not always to a real increase in corneal curvature. Methods A spherical model for the corneal surface and modifying topography software was used to analyze the cause of an error due to instrument design. This study involved modification of the software of a commercially available topographer. Results A small modification of the topography image results in a red zone on the corneal topography color map. Conclusion Corneal modeling indicates that the red zone could be an artifact due to an instrument-induced error. The steep curvature changes after LASIK, signified by the red zone, could be also an error due to the plotting algorithms of the corneal topographer, besides a steep curvature change. |
id |
UNSP_04bd5aaa0da7f80077a3a332cb7085f4 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/173711 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
A steep peripheral ring in irregular cornea topography, real or an instrument error?Irregular corneal astigmatismRed zoneSpherical aberrationTopographyPurpose To demonstrate that the steep peripheral ring (red zone) on corneal topography after myopic laser in situ keratomileusis (LASIK) could possibly due to instrument error and not always to a real increase in corneal curvature. Methods A spherical model for the corneal surface and modifying topography software was used to analyze the cause of an error due to instrument design. This study involved modification of the software of a commercially available topographer. Results A small modification of the topography image results in a red zone on the corneal topography color map. Conclusion Corneal modeling indicates that the red zone could be an artifact due to an instrument-induced error. The steep curvature changes after LASIK, signified by the red zone, could be also an error due to the plotting algorithms of the corneal topographer, besides a steep curvature change.King Khaled Eye Specialist Hospital, Al Urubah Branch Rd, Umm Al Hamam Al GharbiDepartment of Ophthalmology Complejo Asistencial Palencia, Donantes de sangre s/nDepartment of Ophthalmology Faculdade de Medicina de Botucatu – UNESPGalindo Clinic, Francisco Zarandona St 10Rio Hortega University Hospital, Dulzaina St 2Department of Ophthalmology Faculdade de Medicina de Botucatu – UNESPKing Khaled Eye Specialist HospitalComplejo Asistencial PalenciaUniversidade Estadual Paulista (Unesp)Galindo ClinicRio Hortega University HospitalGalindo-Ferreiro, AliciaGalvez-Ruiz, AlbertoSchellini, Silvana A. [UNESP]Galindo-Alonso, Julio2018-12-11T17:07:24Z2018-12-11T17:07:24Z2016-07-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article175-179application/pdfhttp://dx.doi.org/10.1016/j.sjopt.2016.04.002Saudi Journal of Ophthalmology, v. 30, n. 3, p. 175-179, 2016.1319-4534http://hdl.handle.net/11449/17371110.1016/j.sjopt.2016.04.0022-s2.0-849939849512-s2.0-84993984951.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengSaudi Journal of Ophthalmology0,451info:eu-repo/semantics/openAccess2024-08-16T18:43:51Zoai:repositorio.unesp.br:11449/173711Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-16T18:43:51Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
A steep peripheral ring in irregular cornea topography, real or an instrument error? |
title |
A steep peripheral ring in irregular cornea topography, real or an instrument error? |
spellingShingle |
A steep peripheral ring in irregular cornea topography, real or an instrument error? A steep peripheral ring in irregular cornea topography, real or an instrument error? Galindo-Ferreiro, Alicia Irregular corneal astigmatism Red zone Spherical aberration Topography Galindo-Ferreiro, Alicia Irregular corneal astigmatism Red zone Spherical aberration Topography |
title_short |
A steep peripheral ring in irregular cornea topography, real or an instrument error? |
title_full |
A steep peripheral ring in irregular cornea topography, real or an instrument error? |
title_fullStr |
A steep peripheral ring in irregular cornea topography, real or an instrument error? A steep peripheral ring in irregular cornea topography, real or an instrument error? |
title_full_unstemmed |
A steep peripheral ring in irregular cornea topography, real or an instrument error? A steep peripheral ring in irregular cornea topography, real or an instrument error? |
title_sort |
A steep peripheral ring in irregular cornea topography, real or an instrument error? |
author |
Galindo-Ferreiro, Alicia |
author_facet |
Galindo-Ferreiro, Alicia Galindo-Ferreiro, Alicia Galvez-Ruiz, Alberto Schellini, Silvana A. [UNESP] Galindo-Alonso, Julio Galvez-Ruiz, Alberto Schellini, Silvana A. [UNESP] Galindo-Alonso, Julio |
author_role |
author |
author2 |
Galvez-Ruiz, Alberto Schellini, Silvana A. [UNESP] Galindo-Alonso, Julio |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
King Khaled Eye Specialist Hospital Complejo Asistencial Palencia Universidade Estadual Paulista (Unesp) Galindo Clinic Rio Hortega University Hospital |
dc.contributor.author.fl_str_mv |
Galindo-Ferreiro, Alicia Galvez-Ruiz, Alberto Schellini, Silvana A. [UNESP] Galindo-Alonso, Julio |
dc.subject.por.fl_str_mv |
Irregular corneal astigmatism Red zone Spherical aberration Topography |
topic |
Irregular corneal astigmatism Red zone Spherical aberration Topography |
description |
Purpose To demonstrate that the steep peripheral ring (red zone) on corneal topography after myopic laser in situ keratomileusis (LASIK) could possibly due to instrument error and not always to a real increase in corneal curvature. Methods A spherical model for the corneal surface and modifying topography software was used to analyze the cause of an error due to instrument design. This study involved modification of the software of a commercially available topographer. Results A small modification of the topography image results in a red zone on the corneal topography color map. Conclusion Corneal modeling indicates that the red zone could be an artifact due to an instrument-induced error. The steep curvature changes after LASIK, signified by the red zone, could be also an error due to the plotting algorithms of the corneal topographer, besides a steep curvature change. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-07-01 2018-12-11T17:07:24Z 2018-12-11T17:07:24Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1016/j.sjopt.2016.04.002 Saudi Journal of Ophthalmology, v. 30, n. 3, p. 175-179, 2016. 1319-4534 http://hdl.handle.net/11449/173711 10.1016/j.sjopt.2016.04.002 2-s2.0-84993984951 2-s2.0-84993984951.pdf |
url |
http://dx.doi.org/10.1016/j.sjopt.2016.04.002 http://hdl.handle.net/11449/173711 |
identifier_str_mv |
Saudi Journal of Ophthalmology, v. 30, n. 3, p. 175-179, 2016. 1319-4534 10.1016/j.sjopt.2016.04.002 2-s2.0-84993984951 2-s2.0-84993984951.pdf |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Saudi Journal of Ophthalmology 0,451 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
175-179 application/pdf |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1822231335375208448 |
dc.identifier.doi.none.fl_str_mv |
10.1016/j.sjopt.2016.04.002 |