Thickness and marking quality of different occlusal contact registration strips
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1590/1678-775720140117 http://hdl.handle.net/11449/117914 |
Resumo: | ObjectiveEvaluate the thickness and the marking quality of different occlusal contact registration strips (OCRS) and a possible correlation between them. Material and MethodThe following OCRS were selected: Accufilm II, BK20, BK21, BK22, BK23, BK28, and BK31. The thickness was measured in three points of the OCRS with an electronic measuring device (TESA), and the mean was calculated. To produce the marks on the strips, composite resin specimens were adapted to a universal testing machine (Versat 2000) with 40 kgf load cell at a speed of 1.0 mm/min. The mark images were photographed with a stereoscopic microscope (Stemi SV11) and processed and analyzed by the 550-Leica Qwin® analyzer. ResultValues (μm) found in the 1st and 2nd thickness measurements were: Accufilm II - 16.4 and 14.2; BK20 - 10.0 and 8.1; BK21 - 9.5 and 8.0; BK22 - 9.7 and 8.7; BK23 - 9.8 and 7.9; BK28 - 12.8 and 10.0; and BK31 - 8.4 and 8.0, respectively. The mean (mm2) values found in the mark areas were: Accufilm II - 0.078; BK20 - 0.035; BK21 - 0.045; BK22 - 0.012; BK23 - 0.022; BK28 - 0.024; and BK31 - 0.024. The results were submitted to the Kruskal-Wallis (p<0.05) and Pearson’s correlation tests. ConclusionOnly in the 2nd measurement, the OCRS thickness observed was similar to the value indicated by the manufacturers; the Accufilm II and the BK28 strips showed the better marks; and no correlation was found between the thickness and the marking area. |
id |
UNSP_07000aeb099e1d1e1bafe61867166648 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/117914 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Thickness and marking quality of different occlusal contact registration stripsDental occlusionOcclusal adjustmentProsthodonticsDentistryOral diagnosisObjectiveEvaluate the thickness and the marking quality of different occlusal contact registration strips (OCRS) and a possible correlation between them. Material and MethodThe following OCRS were selected: Accufilm II, BK20, BK21, BK22, BK23, BK28, and BK31. The thickness was measured in three points of the OCRS with an electronic measuring device (TESA), and the mean was calculated. To produce the marks on the strips, composite resin specimens were adapted to a universal testing machine (Versat 2000) with 40 kgf load cell at a speed of 1.0 mm/min. The mark images were photographed with a stereoscopic microscope (Stemi SV11) and processed and analyzed by the 550-Leica Qwin® analyzer. ResultValues (μm) found in the 1st and 2nd thickness measurements were: Accufilm II - 16.4 and 14.2; BK20 - 10.0 and 8.1; BK21 - 9.5 and 8.0; BK22 - 9.7 and 8.7; BK23 - 9.8 and 7.9; BK28 - 12.8 and 10.0; and BK31 - 8.4 and 8.0, respectively. The mean (mm2) values found in the mark areas were: Accufilm II - 0.078; BK20 - 0.035; BK21 - 0.045; BK22 - 0.012; BK23 - 0.022; BK28 - 0.024; and BK31 - 0.024. The results were submitted to the Kruskal-Wallis (p<0.05) and Pearson’s correlation tests. ConclusionOnly in the 2nd measurement, the OCRS thickness observed was similar to the value indicated by the manufacturers; the Accufilm II and the BK28 strips showed the better marks; and no correlation was found between the thickness and the marking area.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)São PauloUniv. Estadual Paulista Science and Technology Institute School of DentistryUniversity of Taubaté Department of DentistryUniversidade Estadual Paulista Science and Technology Institute School of DentistryUniversidade Estadual Paulista Science and Technology Institute School of DentistryFaculdade De Odontologia De Bauru - USPSão PauloUniv. Estadual Paulista Science and Technology Institute School of DentistryUniversity of Taubaté Department of DentistryUniversidade Estadual Paulista (Unesp)Toledo, Maria Fernanda De Souza Mauá SerapiãoJóias, Renata Pilli [UNESP]Marques-iasi, Yves SantiniNeves, Ana Christina ClaroRode, Sigmar de Mello [UNESP]2015-03-19T16:20:28Z2015-03-19T16:20:28Z2014-12-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article516-521application/pdfhttp://dx.doi.org/10.1590/1678-775720140117Journal of Applied Oral Science. Faculdade De Odontologia De Bauru - USP, v. 22, n. 6, p. 516-521, 2014.1678-7757http://hdl.handle.net/11449/11791410.1590/1678-775720140117S1678-77572014000600516S1678-77572014000600516.pdf3422118958429909SciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of Applied Oral Science1.7090,645info:eu-repo/semantics/openAccess2023-12-10T06:22:23Zoai:repositorio.unesp.br:11449/117914Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T19:58:31.057442Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Thickness and marking quality of different occlusal contact registration strips |
title |
Thickness and marking quality of different occlusal contact registration strips |
spellingShingle |
Thickness and marking quality of different occlusal contact registration strips Toledo, Maria Fernanda De Souza Mauá Serapião Dental occlusion Occlusal adjustment Prosthodontics Dentistry Oral diagnosis |
title_short |
Thickness and marking quality of different occlusal contact registration strips |
title_full |
Thickness and marking quality of different occlusal contact registration strips |
title_fullStr |
Thickness and marking quality of different occlusal contact registration strips |
title_full_unstemmed |
Thickness and marking quality of different occlusal contact registration strips |
title_sort |
Thickness and marking quality of different occlusal contact registration strips |
author |
Toledo, Maria Fernanda De Souza Mauá Serapião |
author_facet |
Toledo, Maria Fernanda De Souza Mauá Serapião Jóias, Renata Pilli [UNESP] Marques-iasi, Yves Santini Neves, Ana Christina Claro Rode, Sigmar de Mello [UNESP] |
author_role |
author |
author2 |
Jóias, Renata Pilli [UNESP] Marques-iasi, Yves Santini Neves, Ana Christina Claro Rode, Sigmar de Mello [UNESP] |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
São Paulo Univ. Estadual Paulista Science and Technology Institute School of Dentistry University of Taubaté Department of Dentistry Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Toledo, Maria Fernanda De Souza Mauá Serapião Jóias, Renata Pilli [UNESP] Marques-iasi, Yves Santini Neves, Ana Christina Claro Rode, Sigmar de Mello [UNESP] |
dc.subject.por.fl_str_mv |
Dental occlusion Occlusal adjustment Prosthodontics Dentistry Oral diagnosis |
topic |
Dental occlusion Occlusal adjustment Prosthodontics Dentistry Oral diagnosis |
description |
ObjectiveEvaluate the thickness and the marking quality of different occlusal contact registration strips (OCRS) and a possible correlation between them. Material and MethodThe following OCRS were selected: Accufilm II, BK20, BK21, BK22, BK23, BK28, and BK31. The thickness was measured in three points of the OCRS with an electronic measuring device (TESA), and the mean was calculated. To produce the marks on the strips, composite resin specimens were adapted to a universal testing machine (Versat 2000) with 40 kgf load cell at a speed of 1.0 mm/min. The mark images were photographed with a stereoscopic microscope (Stemi SV11) and processed and analyzed by the 550-Leica Qwin® analyzer. ResultValues (μm) found in the 1st and 2nd thickness measurements were: Accufilm II - 16.4 and 14.2; BK20 - 10.0 and 8.1; BK21 - 9.5 and 8.0; BK22 - 9.7 and 8.7; BK23 - 9.8 and 7.9; BK28 - 12.8 and 10.0; and BK31 - 8.4 and 8.0, respectively. The mean (mm2) values found in the mark areas were: Accufilm II - 0.078; BK20 - 0.035; BK21 - 0.045; BK22 - 0.012; BK23 - 0.022; BK28 - 0.024; and BK31 - 0.024. The results were submitted to the Kruskal-Wallis (p<0.05) and Pearson’s correlation tests. ConclusionOnly in the 2nd measurement, the OCRS thickness observed was similar to the value indicated by the manufacturers; the Accufilm II and the BK28 strips showed the better marks; and no correlation was found between the thickness and the marking area. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-12-01 2015-03-19T16:20:28Z 2015-03-19T16:20:28Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/1678-775720140117 Journal of Applied Oral Science. Faculdade De Odontologia De Bauru - USP, v. 22, n. 6, p. 516-521, 2014. 1678-7757 http://hdl.handle.net/11449/117914 10.1590/1678-775720140117 S1678-77572014000600516 S1678-77572014000600516.pdf 3422118958429909 |
url |
http://dx.doi.org/10.1590/1678-775720140117 http://hdl.handle.net/11449/117914 |
identifier_str_mv |
Journal of Applied Oral Science. Faculdade De Odontologia De Bauru - USP, v. 22, n. 6, p. 516-521, 2014. 1678-7757 10.1590/1678-775720140117 S1678-77572014000600516 S1678-77572014000600516.pdf 3422118958429909 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Journal of Applied Oral Science 1.709 0,645 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
516-521 application/pdf |
dc.publisher.none.fl_str_mv |
Faculdade De Odontologia De Bauru - USP |
publisher.none.fl_str_mv |
Faculdade De Odontologia De Bauru - USP |
dc.source.none.fl_str_mv |
SciELO reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129144822693888 |