Thickness and marking quality of different occlusal contact registration strips
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of applied oral science (Online) |
Texto Completo: | https://www.revistas.usp.br/jaos/article/view/100912 |
Resumo: | Objectives Evaluate the thickness and the marking quality of different occlusal contact registration strips (OCRS) and a possible correlation between them. Material and Methods The following OCRS were selected: Accufilm II, BK20, BK21, BK22, BK23, BK28, and BK31. The thickness was measured in three points of the OCRS with an electronic measuring device (TESA), and the mean was calculated. To produce the marks on the strips, composite resin specimens were adapted to a universal testing machine (Versat 2000) with 40 kgf load cell at a speed of 1.0 mm/min. The mark images were photographed with a stereoscopic microscope (Stemi SV11) and processed and analyzed by the 550-Leica Qwin® analyzer. Results Values (μm) found in the 1st and 2nd thickness measurements were: Accufilm II - 16.4 and 14.2; BK20 - 10.0 and 8.1; BK21 - 9.5 and 8.0; BK22 - 9.7 and 8.7; BK23 - 9.8 and 7.9; BK28 - 12.8 and 10.0; and BK31 - 8.4 and 8.0, respectively. The mean (mm2) values found in the mark areas were: Accufilm II - 0.078; BK20 - 0.035; BK21 - 0.045; BK22 - 0.012; BK23 - 0.022; BK28 - 0.024; and BK31 - 0.024. The results were submitted to the Kruskal-Wallis (p |
id |
USP-17_4ffc5bbaf9762fe6dd4603a2d7e7deda |
---|---|
oai_identifier_str |
oai:revistas.usp.br:article/100912 |
network_acronym_str |
USP-17 |
network_name_str |
Journal of applied oral science (Online) |
repository_id_str |
|
spelling |
Thickness and marking quality of different occlusal contact registration strips Objectives Evaluate the thickness and the marking quality of different occlusal contact registration strips (OCRS) and a possible correlation between them. Material and Methods The following OCRS were selected: Accufilm II, BK20, BK21, BK22, BK23, BK28, and BK31. The thickness was measured in three points of the OCRS with an electronic measuring device (TESA), and the mean was calculated. To produce the marks on the strips, composite resin specimens were adapted to a universal testing machine (Versat 2000) with 40 kgf load cell at a speed of 1.0 mm/min. The mark images were photographed with a stereoscopic microscope (Stemi SV11) and processed and analyzed by the 550-Leica Qwin® analyzer. Results Values (μm) found in the 1st and 2nd thickness measurements were: Accufilm II - 16.4 and 14.2; BK20 - 10.0 and 8.1; BK21 - 9.5 and 8.0; BK22 - 9.7 and 8.7; BK23 - 9.8 and 7.9; BK28 - 12.8 and 10.0; and BK31 - 8.4 and 8.0, respectively. The mean (mm2) values found in the mark areas were: Accufilm II - 0.078; BK20 - 0.035; BK21 - 0.045; BK22 - 0.012; BK23 - 0.022; BK28 - 0.024; and BK31 - 0.024. The results were submitted to the Kruskal-Wallis (pUniversidade de São Paulo. Faculdade de Odontologia de Bauru2014-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/10091210.1590/1678-775720140117Journal of Applied Oral Science; Vol. 22 No. 6 (2014); 516-521Journal of Applied Oral Science; Vol. 22 Núm. 6 (2014); 516-521Journal of Applied Oral Science; v. 22 n. 6 (2014); 516-5211678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/100912/99582Copyright (c) 2014 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessTOLEDO, Maria Fernanda de Souza Mauá Serapião JÓIAS, Renata Pilli MARQUES-IASI, Yves Santini NEVES, Ana Christina Claro RODE, Sigmar de Mello 2015-07-28T17:05:08Zoai:revistas.usp.br:article/100912Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2015-07-28T17:05:08Journal of applied oral science (Online) - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
Thickness and marking quality of different occlusal contact registration strips |
title |
Thickness and marking quality of different occlusal contact registration strips |
spellingShingle |
Thickness and marking quality of different occlusal contact registration strips TOLEDO, Maria Fernanda de Souza Mauá Serapião |
title_short |
Thickness and marking quality of different occlusal contact registration strips |
title_full |
Thickness and marking quality of different occlusal contact registration strips |
title_fullStr |
Thickness and marking quality of different occlusal contact registration strips |
title_full_unstemmed |
Thickness and marking quality of different occlusal contact registration strips |
title_sort |
Thickness and marking quality of different occlusal contact registration strips |
author |
TOLEDO, Maria Fernanda de Souza Mauá Serapião |
author_facet |
TOLEDO, Maria Fernanda de Souza Mauá Serapião JÓIAS, Renata Pilli MARQUES-IASI, Yves Santini NEVES, Ana Christina Claro RODE, Sigmar de Mello |
author_role |
author |
author2 |
JÓIAS, Renata Pilli MARQUES-IASI, Yves Santini NEVES, Ana Christina Claro RODE, Sigmar de Mello |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
TOLEDO, Maria Fernanda de Souza Mauá Serapião JÓIAS, Renata Pilli MARQUES-IASI, Yves Santini NEVES, Ana Christina Claro RODE, Sigmar de Mello |
description |
Objectives Evaluate the thickness and the marking quality of different occlusal contact registration strips (OCRS) and a possible correlation between them. Material and Methods The following OCRS were selected: Accufilm II, BK20, BK21, BK22, BK23, BK28, and BK31. The thickness was measured in three points of the OCRS with an electronic measuring device (TESA), and the mean was calculated. To produce the marks on the strips, composite resin specimens were adapted to a universal testing machine (Versat 2000) with 40 kgf load cell at a speed of 1.0 mm/min. The mark images were photographed with a stereoscopic microscope (Stemi SV11) and processed and analyzed by the 550-Leica Qwin® analyzer. Results Values (μm) found in the 1st and 2nd thickness measurements were: Accufilm II - 16.4 and 14.2; BK20 - 10.0 and 8.1; BK21 - 9.5 and 8.0; BK22 - 9.7 and 8.7; BK23 - 9.8 and 7.9; BK28 - 12.8 and 10.0; and BK31 - 8.4 and 8.0, respectively. The mean (mm2) values found in the mark areas were: Accufilm II - 0.078; BK20 - 0.035; BK21 - 0.045; BK22 - 0.012; BK23 - 0.022; BK28 - 0.024; and BK31 - 0.024. The results were submitted to the Kruskal-Wallis (p |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/100912 10.1590/1678-775720140117 |
url |
https://www.revistas.usp.br/jaos/article/view/100912 |
identifier_str_mv |
10.1590/1678-775720140117 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/100912/99582 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2014 Journal of Applied Oral Science info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2014 Journal of Applied Oral Science |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
dc.source.none.fl_str_mv |
Journal of Applied Oral Science; Vol. 22 No. 6 (2014); 516-521 Journal of Applied Oral Science; Vol. 22 Núm. 6 (2014); 516-521 Journal of Applied Oral Science; v. 22 n. 6 (2014); 516-521 1678-7765 1678-7757 reponame:Journal of applied oral science (Online) instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Journal of applied oral science (Online) |
collection |
Journal of applied oral science (Online) |
repository.name.fl_str_mv |
Journal of applied oral science (Online) - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||jaos@usp.br |
_version_ |
1800221678693777408 |