Surface properties of Ti-35Nb-7Zr-5Ta: Effects of long-term immersion in artificial saliva and fluoride solution

Detalhes bibliográficos
Autor(a) principal: Miotto, Larissa N. [UNESP]
Data de Publicação: 2016
Outros Autores: Fais, Laiza M. G. [UNESP], Ribeiro, Ana L. R., Vaz, Luis G. [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1016/j.prosdent.2015.10.024
http://hdl.handle.net/11449/161734
Resumo: Statement of problem. The mechanical properties of new titanium alloys with an elastic modulus closest to cortical bone have been studied. However, potentially damaging conditions experienced in the oral cavity, such as fluoride ions, can initiate a localized or crevice process of corrosive degradation in the alloy surfaces. Purpose. The purpose of this in vitro study was to evaluate the effects of long-term immersion in artificial saliva or in fluoride solution on mean roughness (R-a), Vickers hardness, and topography of the new titanium alloy Ti-35Nb-7Zr-5Ta (TNZT) compared with those of cp Ti and Ti-6AI-4V (TAV). Material and methods. Disks (N=210) were divided into cp Ti, TAV, and TNZT and subdivided according to the following treatments: no immersion (N-, control), immersion in artificial saliva (S), and immersion in fluoride (F) during periods equivalent to 5, 10, 15, and 20 years. The R-a and Vickers hardness were measured with a profilometer and a hardness tester. The topography was analyzed by scanning electronic microscopy. Data were compared using the Kruskal-Wallis and Dunn tests (alpha=.05). Results. Values of R-a and hardness were significantly different among the metals (R-a: TAV<TNZT<cp Ti; P<.05); and hardness (cp Ti<TNZT<TAV; P<.05); with a tendency for R-a to increase for TAV after 20 years of fluoride immersion and changes in hardness values of TAV and TNZT after immersion. TAV surfaces showed a heterogeneous appearance. Conclusions. Long-term immersion in NaF did not change the roughness of Ti-35Nb-7Zr-5Ta. However, the hardness of the alloys increased with immersion.
id UNSP_0db2a2b6bfbd66265a83b972618ab256
oai_identifier_str oai:repositorio.unesp.br:11449/161734
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Surface properties of Ti-35Nb-7Zr-5Ta: Effects of long-term immersion in artificial saliva and fluoride solutionStatement of problem. The mechanical properties of new titanium alloys with an elastic modulus closest to cortical bone have been studied. However, potentially damaging conditions experienced in the oral cavity, such as fluoride ions, can initiate a localized or crevice process of corrosive degradation in the alloy surfaces. Purpose. The purpose of this in vitro study was to evaluate the effects of long-term immersion in artificial saliva or in fluoride solution on mean roughness (R-a), Vickers hardness, and topography of the new titanium alloy Ti-35Nb-7Zr-5Ta (TNZT) compared with those of cp Ti and Ti-6AI-4V (TAV). Material and methods. Disks (N=210) were divided into cp Ti, TAV, and TNZT and subdivided according to the following treatments: no immersion (N-, control), immersion in artificial saliva (S), and immersion in fluoride (F) during periods equivalent to 5, 10, 15, and 20 years. The R-a and Vickers hardness were measured with a profilometer and a hardness tester. The topography was analyzed by scanning electronic microscopy. Data were compared using the Kruskal-Wallis and Dunn tests (alpha=.05). Results. Values of R-a and hardness were significantly different among the metals (R-a: TAV<TNZT<cp Ti; P<.05); and hardness (cp Ti<TNZT<TAV; P<.05); with a tendency for R-a to increase for TAV after 20 years of fluoride immersion and changes in hardness values of TAV and TNZT after immersion. TAV surfaces showed a heterogeneous appearance. Conclusions. Long-term immersion in NaF did not change the roughness of Ti-35Nb-7Zr-5Ta. However, the hardness of the alloys increased with immersion.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Sao Paulo State Univ, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, 1680 Humaita St, BR-14801903 Sao Paulo, BrazilFac Ciencias Tocantins FACIT, Araguaina, Tocantins, BrazilSao Paulo State Univ, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, 1680 Humaita St, BR-14801903 Sao Paulo, BrazilFAPESP: 2011/17861-3FAPESP: 2011/19915-3Elsevier B.V.Universidade Estadual Paulista (Unesp)Fac Ciencias Tocantins FACITMiotto, Larissa N. [UNESP]Fais, Laiza M. G. [UNESP]Ribeiro, Ana L. R.Vaz, Luis G. [UNESP]2018-11-26T16:48:25Z2018-11-26T16:48:25Z2016-07-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article102-111application/pdfhttp://dx.doi.org/10.1016/j.prosdent.2015.10.024Journal Of Prosthetic Dentistry. New York: Mosby-elsevier, v. 116, n. 1, p. 102-111, 2016.0022-3913http://hdl.handle.net/11449/16173410.1016/j.prosdent.2015.10.024WOS:000379889300020WOS000379889300020.pdfWeb of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal Of Prosthetic Dentistry1,087info:eu-repo/semantics/openAccess2023-12-25T06:22:19Zoai:repositorio.unesp.br:11449/161734Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462023-12-25T06:22:19Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Surface properties of Ti-35Nb-7Zr-5Ta: Effects of long-term immersion in artificial saliva and fluoride solution
title Surface properties of Ti-35Nb-7Zr-5Ta: Effects of long-term immersion in artificial saliva and fluoride solution
spellingShingle Surface properties of Ti-35Nb-7Zr-5Ta: Effects of long-term immersion in artificial saliva and fluoride solution
Miotto, Larissa N. [UNESP]
title_short Surface properties of Ti-35Nb-7Zr-5Ta: Effects of long-term immersion in artificial saliva and fluoride solution
title_full Surface properties of Ti-35Nb-7Zr-5Ta: Effects of long-term immersion in artificial saliva and fluoride solution
title_fullStr Surface properties of Ti-35Nb-7Zr-5Ta: Effects of long-term immersion in artificial saliva and fluoride solution
title_full_unstemmed Surface properties of Ti-35Nb-7Zr-5Ta: Effects of long-term immersion in artificial saliva and fluoride solution
title_sort Surface properties of Ti-35Nb-7Zr-5Ta: Effects of long-term immersion in artificial saliva and fluoride solution
author Miotto, Larissa N. [UNESP]
author_facet Miotto, Larissa N. [UNESP]
Fais, Laiza M. G. [UNESP]
Ribeiro, Ana L. R.
Vaz, Luis G. [UNESP]
author_role author
author2 Fais, Laiza M. G. [UNESP]
Ribeiro, Ana L. R.
Vaz, Luis G. [UNESP]
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Fac Ciencias Tocantins FACIT
dc.contributor.author.fl_str_mv Miotto, Larissa N. [UNESP]
Fais, Laiza M. G. [UNESP]
Ribeiro, Ana L. R.
Vaz, Luis G. [UNESP]
description Statement of problem. The mechanical properties of new titanium alloys with an elastic modulus closest to cortical bone have been studied. However, potentially damaging conditions experienced in the oral cavity, such as fluoride ions, can initiate a localized or crevice process of corrosive degradation in the alloy surfaces. Purpose. The purpose of this in vitro study was to evaluate the effects of long-term immersion in artificial saliva or in fluoride solution on mean roughness (R-a), Vickers hardness, and topography of the new titanium alloy Ti-35Nb-7Zr-5Ta (TNZT) compared with those of cp Ti and Ti-6AI-4V (TAV). Material and methods. Disks (N=210) were divided into cp Ti, TAV, and TNZT and subdivided according to the following treatments: no immersion (N-, control), immersion in artificial saliva (S), and immersion in fluoride (F) during periods equivalent to 5, 10, 15, and 20 years. The R-a and Vickers hardness were measured with a profilometer and a hardness tester. The topography was analyzed by scanning electronic microscopy. Data were compared using the Kruskal-Wallis and Dunn tests (alpha=.05). Results. Values of R-a and hardness were significantly different among the metals (R-a: TAV<TNZT<cp Ti; P<.05); and hardness (cp Ti<TNZT<TAV; P<.05); with a tendency for R-a to increase for TAV after 20 years of fluoride immersion and changes in hardness values of TAV and TNZT after immersion. TAV surfaces showed a heterogeneous appearance. Conclusions. Long-term immersion in NaF did not change the roughness of Ti-35Nb-7Zr-5Ta. However, the hardness of the alloys increased with immersion.
publishDate 2016
dc.date.none.fl_str_mv 2016-07-01
2018-11-26T16:48:25Z
2018-11-26T16:48:25Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/j.prosdent.2015.10.024
Journal Of Prosthetic Dentistry. New York: Mosby-elsevier, v. 116, n. 1, p. 102-111, 2016.
0022-3913
http://hdl.handle.net/11449/161734
10.1016/j.prosdent.2015.10.024
WOS:000379889300020
WOS000379889300020.pdf
url http://dx.doi.org/10.1016/j.prosdent.2015.10.024
http://hdl.handle.net/11449/161734
identifier_str_mv Journal Of Prosthetic Dentistry. New York: Mosby-elsevier, v. 116, n. 1, p. 102-111, 2016.
0022-3913
10.1016/j.prosdent.2015.10.024
WOS:000379889300020
WOS000379889300020.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Journal Of Prosthetic Dentistry
1,087
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 102-111
application/pdf
dc.publisher.none.fl_str_mv Elsevier B.V.
publisher.none.fl_str_mv Elsevier B.V.
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1803047109689081856