Sensitive voltammetric sensor for fast detection of mycolic acids present in mycobacteria
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://www.electrochemsci.org/papers/vol8/80506591.pdf http://hdl.handle.net/11449/75644 |
Resumo: | The present work describes a fast, simple, and economic method for electroanalytical detection of mycolic acids (MA) present in the cell envelope of Mycobacterium, Corynebacterium, Nocardia, and Rhodococcus. MA are pre-concentrated on a glassy carbon electrode modified with a poly-L-lysine film, resulting in a well-defined reduction wave at -0.73 V (vs. Ag/AgCl) and being the base for detection and quantification of bacteria, like Mycobacterium smegmatis, used as model in this work. The method was optimized and analytical curves were constructed for Mycobacterium smegmatis by using square wave voltammetry. The method offers a detection limit of 5.9 e 10 colony forming units (CFU) mL-1, and the reproducibility for 10 measurements at 1.4 e 102 CFU mL-1 showed a standard deviation of 1.8%. The method was successfully applied for detection of MA in water samples as indirect measure of the presence of Mycobacteria. © 2013 by ESG. |
id |
UNSP_13c8b7d261ab92a9800b8c5eddbc96a5 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/75644 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Sensitive voltammetric sensor for fast detection of mycolic acids present in mycobacteriaElectroanalysis of bacteriaM. smegmatisModified electrodeMycobacteriaMycolic acidsVoltammetric sensorThe present work describes a fast, simple, and economic method for electroanalytical detection of mycolic acids (MA) present in the cell envelope of Mycobacterium, Corynebacterium, Nocardia, and Rhodococcus. MA are pre-concentrated on a glassy carbon electrode modified with a poly-L-lysine film, resulting in a well-defined reduction wave at -0.73 V (vs. Ag/AgCl) and being the base for detection and quantification of bacteria, like Mycobacterium smegmatis, used as model in this work. The method was optimized and analytical curves were constructed for Mycobacterium smegmatis by using square wave voltammetry. The method offers a detection limit of 5.9 e 10 colony forming units (CFU) mL-1, and the reproducibility for 10 measurements at 1.4 e 102 CFU mL-1 showed a standard deviation of 1.8%. The method was successfully applied for detection of MA in water samples as indirect measure of the presence of Mycobacteria. © 2013 by ESG.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Department of Analytical Chemistry Institute of Chemistry-Araraquara UNESP, Rua Francisco Degni, 55 - Bairro Quitandinha, 14800-900, AraraquaraDepartment of Biological Science Faculty of Pharmaceutical Science Araraquara, UNESP, Rodovia Araraquara - Jaú, Km 01, 14801-902, AraraquaraDepartment of Analytical Chemistry Institute of Chemistry-Araraquara UNESP, Rua Francisco Degni, 55 - Bairro Quitandinha, 14800-900, AraraquaraDepartment of Biological Science Faculty of Pharmaceutical Science Araraquara, UNESP, Rodovia Araraquara - Jaú, Km 01, 14801-902, AraraquaraFAPESP: 09/09403-5Universidade Estadual Paulista (Unesp)Brugnera, Michelle Fernanda [UNESP]Miyata, Marcelo [UNESP]Leite, Clarice Queico Fujimura [UNESP]Zanoni, Maria Valnice Boldrin [UNESP]2014-05-27T11:29:40Z2014-05-27T11:29:40Z2013-06-12info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article6591-6602application/pdfhttp://www.electrochemsci.org/papers/vol8/80506591.pdfInternational Journal of Electrochemical Science, v. 8, n. 5, p. 6591-6602, 2013.1452-3981http://hdl.handle.net/11449/75644WOS:0003198610000512-s2.0-848786812632-s2.0-84878681263.pdf0000-0002-2296-1393Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengInternational Journal of Electrochemical Science1.3690,366info:eu-repo/semantics/openAccess2023-12-27T06:21:28Zoai:repositorio.unesp.br:11449/75644Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T21:27:13.591334Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Sensitive voltammetric sensor for fast detection of mycolic acids present in mycobacteria |
title |
Sensitive voltammetric sensor for fast detection of mycolic acids present in mycobacteria |
spellingShingle |
Sensitive voltammetric sensor for fast detection of mycolic acids present in mycobacteria Brugnera, Michelle Fernanda [UNESP] Electroanalysis of bacteria M. smegmatis Modified electrode Mycobacteria Mycolic acids Voltammetric sensor |
title_short |
Sensitive voltammetric sensor for fast detection of mycolic acids present in mycobacteria |
title_full |
Sensitive voltammetric sensor for fast detection of mycolic acids present in mycobacteria |
title_fullStr |
Sensitive voltammetric sensor for fast detection of mycolic acids present in mycobacteria |
title_full_unstemmed |
Sensitive voltammetric sensor for fast detection of mycolic acids present in mycobacteria |
title_sort |
Sensitive voltammetric sensor for fast detection of mycolic acids present in mycobacteria |
author |
Brugnera, Michelle Fernanda [UNESP] |
author_facet |
Brugnera, Michelle Fernanda [UNESP] Miyata, Marcelo [UNESP] Leite, Clarice Queico Fujimura [UNESP] Zanoni, Maria Valnice Boldrin [UNESP] |
author_role |
author |
author2 |
Miyata, Marcelo [UNESP] Leite, Clarice Queico Fujimura [UNESP] Zanoni, Maria Valnice Boldrin [UNESP] |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Brugnera, Michelle Fernanda [UNESP] Miyata, Marcelo [UNESP] Leite, Clarice Queico Fujimura [UNESP] Zanoni, Maria Valnice Boldrin [UNESP] |
dc.subject.por.fl_str_mv |
Electroanalysis of bacteria M. smegmatis Modified electrode Mycobacteria Mycolic acids Voltammetric sensor |
topic |
Electroanalysis of bacteria M. smegmatis Modified electrode Mycobacteria Mycolic acids Voltammetric sensor |
description |
The present work describes a fast, simple, and economic method for electroanalytical detection of mycolic acids (MA) present in the cell envelope of Mycobacterium, Corynebacterium, Nocardia, and Rhodococcus. MA are pre-concentrated on a glassy carbon electrode modified with a poly-L-lysine film, resulting in a well-defined reduction wave at -0.73 V (vs. Ag/AgCl) and being the base for detection and quantification of bacteria, like Mycobacterium smegmatis, used as model in this work. The method was optimized and analytical curves were constructed for Mycobacterium smegmatis by using square wave voltammetry. The method offers a detection limit of 5.9 e 10 colony forming units (CFU) mL-1, and the reproducibility for 10 measurements at 1.4 e 102 CFU mL-1 showed a standard deviation of 1.8%. The method was successfully applied for detection of MA in water samples as indirect measure of the presence of Mycobacteria. © 2013 by ESG. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-06-12 2014-05-27T11:29:40Z 2014-05-27T11:29:40Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://www.electrochemsci.org/papers/vol8/80506591.pdf International Journal of Electrochemical Science, v. 8, n. 5, p. 6591-6602, 2013. 1452-3981 http://hdl.handle.net/11449/75644 WOS:000319861000051 2-s2.0-84878681263 2-s2.0-84878681263.pdf 0000-0002-2296-1393 |
url |
http://www.electrochemsci.org/papers/vol8/80506591.pdf http://hdl.handle.net/11449/75644 |
identifier_str_mv |
International Journal of Electrochemical Science, v. 8, n. 5, p. 6591-6602, 2013. 1452-3981 WOS:000319861000051 2-s2.0-84878681263 2-s2.0-84878681263.pdf 0000-0002-2296-1393 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
International Journal of Electrochemical Science 1.369 0,366 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
6591-6602 application/pdf |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129321353609216 |