The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters

Detalhes bibliográficos
Autor(a) principal: Martinelli, Bruno
Data de Publicação: 2014
Outros Autores: Damasceno E Souza, Giovana, Ricci, Mariana Dela Coleta, Gimenes, Camila, De Conti, Marta Helena Souza, Barrile, Silvia Regina
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1590/0103-5150.027.001.AO01
http://hdl.handle.net/11449/114236
Resumo: IntroductionThe incentive spirometer helps pulmonary ventilation and the cardiorespiratory changes of its use are controversial. ObjectiveTo evaluate the effect of sets and repetitions on cardiorespiratory parameters using a spirometer alinear flow (SAF). The sample group consisted of 50 young people, healthy and sedentary. The evaluated parameters were: systolic blood pressure (SBP), diastolic (DBP), heart rate (HR), respiratory rate (RR), oxygen saturation (SaO2), minute volume (VE), tidal volume (VT), vital capacity (VC), maximal inspiratory pressure (Pimax), maximal expiratory pressure (Pemax), and peak expiratory flow (PEF). The moments of study were: initial evaluations (M1); 3 sets of 10 repetitions using SAF (M2); 3 sets of 15 repetitions using SAF (M3); and final evaluation (M4). Statistical analysis was made by t test, ANOVA and Tukey test (p < 0.05). ResultSBP and HR decreased in M2 after the 2nd set. In the 3rd set, SBP and RR decreased. Comparing the initial and final variables in M2, SBP and RR decreased, and Pemax increased. After 1st set in M3, SBP and SaO2 decreased. The 2nd set: SBP, HR, RR, and SaO2 decreased. After the 3rd set: SBP, HR, SaO2, and RR decreased. Comparing the initial and final variables in M3, SBP, HR, RR decreased, and Pimax and Pemax increased. Comparing M4 to M1, Pimax, Pemax, and VC increased, and RR decreased. ConclusionThere are changes in cardiorespiratory parameters after the use of a spirometer alinear flow, especially in the sets with more repetitions.
id UNSP_27c8f33613385116516c8944297fa153
oai_identifier_str oai:repositorio.unesp.br:11449/114236
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parametersEfeito das séries e repetições do inspirômetro a fluxo nos parâmetros cardiorrespiratóriosPhysiotherapyPulmonologyRespiratory therapyFisioterapiaPneumologiaTerapia respiratóriaIntroductionThe incentive spirometer helps pulmonary ventilation and the cardiorespiratory changes of its use are controversial. ObjectiveTo evaluate the effect of sets and repetitions on cardiorespiratory parameters using a spirometer alinear flow (SAF). The sample group consisted of 50 young people, healthy and sedentary. The evaluated parameters were: systolic blood pressure (SBP), diastolic (DBP), heart rate (HR), respiratory rate (RR), oxygen saturation (SaO2), minute volume (VE), tidal volume (VT), vital capacity (VC), maximal inspiratory pressure (Pimax), maximal expiratory pressure (Pemax), and peak expiratory flow (PEF). The moments of study were: initial evaluations (M1); 3 sets of 10 repetitions using SAF (M2); 3 sets of 15 repetitions using SAF (M3); and final evaluation (M4). Statistical analysis was made by t test, ANOVA and Tukey test (p < 0.05). ResultSBP and HR decreased in M2 after the 2nd set. In the 3rd set, SBP and RR decreased. Comparing the initial and final variables in M2, SBP and RR decreased, and Pemax increased. After 1st set in M3, SBP and SaO2 decreased. The 2nd set: SBP, HR, RR, and SaO2 decreased. After the 3rd set: SBP, HR, SaO2, and RR decreased. Comparing the initial and final variables in M3, SBP, HR, RR decreased, and Pimax and Pemax increased. Comparing M4 to M1, Pimax, Pemax, and VC increased, and RR decreased. ConclusionThere are changes in cardiorespiratory parameters after the use of a spirometer alinear flow, especially in the sets with more repetitions.Introdução Os incentivadores respiratórios auxiliam na ventilação pulmonar e as modificações cardiorrespiratórias mediante seu uso ainda são discutidas. Objetivo Avaliar efeito das séries e repetições com uso do inspirômetro alinear a fluxo (IAF) nos parâmetros cardiorrespiratórios. Materiais e métodos A amostra foi composta de 50 jovens, saudáveis e sedentários. Os parâmetros avaliados foram: pressão arterial (PA), frequência de pulso (FP), frequência respiratória (FR), saturação (SatO2), volume minuto (VM), volume corrente (VC), capacidade vital (CV), pressão inspiratória (Pimáx), pressão expiratória (Pemáx) e fluxometria. Os momentos foram: avaliações inicial (M1); uso do IAF em 3 séries de 10 repetições (M2); 3 séries de 15 repetições (M3); avaliação final (M4). A análise estatística se deu pelo teste “t” de Student, ANOVA e Teste de Tukey (p < 0,05). Resultados No M2, após a 2ª série houve diminuição da PAS e FP; na 3ª série: diminuição da PAS e FR. Comparando as variáveis iniciais e finais do M2, houve diminuição da PAS e FR, e aumento da Pemáx. No M3, 1ª série, houve diminuição da PAS e SatO2. Na 2ª série: diminuição da PAS, FP, FR e SatO2. Após a 3ª série: diminuição da PAS, FP, SatO2 e FR. Comparando as variáveis iniciais e finais do M3, houve diminuição da PAS, FP, FR; aumento da Pimáx e Pemáx. Comparando M4 com M1, houve aumento da Pimáx e Pemáx, diminuição da FR e aumento da CV. Conclusão Há alterações nos parâmetros cardiorrespiratórios após utilização do IAF, principalmente nas séries com maiores repetições.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Unesp Faculdade de Medicina de BotucatuUniversidade do Sagrado CoraçãoUniversidade Estadual PaulistaUnesp Faculdade de Medicina de BotucatuUniversidade Estadual PaulistaPontifícia Universidade Católica do ParanáUniversidade Estadual Paulista (Unesp)Universidade do Sagrado CoraçãoMartinelli, BrunoDamasceno E Souza, GiovanaRicci, Mariana Dela ColetaGimenes, CamilaDe Conti, Marta Helena SouzaBarrile, Silvia Regina2015-02-02T12:39:22Z2015-02-02T12:39:22Z2014-03-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article11-19application/pdfhttp://dx.doi.org/10.1590/0103-5150.027.001.AO01Fisioterapia em Movimento. Pontifícia Universidade Católica do Paraná, v. 27, n. 1, p. 11-19, 2014.0103-5150http://hdl.handle.net/11449/11423610.1590/0103-5150.027.001.AO01S0103-51502014000100011S0103-51502014000100011.pdfSciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengFisioterapia em Movimentoinfo:eu-repo/semantics/openAccess2024-01-04T06:26:21Zoai:repositorio.unesp.br:11449/114236Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T22:07:16.446395Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters
Efeito das séries e repetições do inspirômetro a fluxo nos parâmetros cardiorrespiratórios
title The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters
spellingShingle The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters
Martinelli, Bruno
Physiotherapy
Pulmonology
Respiratory therapy
Fisioterapia
Pneumologia
Terapia respiratória
title_short The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters
title_full The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters
title_fullStr The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters
title_full_unstemmed The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters
title_sort The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters
author Martinelli, Bruno
author_facet Martinelli, Bruno
Damasceno E Souza, Giovana
Ricci, Mariana Dela Coleta
Gimenes, Camila
De Conti, Marta Helena Souza
Barrile, Silvia Regina
author_role author
author2 Damasceno E Souza, Giovana
Ricci, Mariana Dela Coleta
Gimenes, Camila
De Conti, Marta Helena Souza
Barrile, Silvia Regina
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Universidade do Sagrado Coração
dc.contributor.author.fl_str_mv Martinelli, Bruno
Damasceno E Souza, Giovana
Ricci, Mariana Dela Coleta
Gimenes, Camila
De Conti, Marta Helena Souza
Barrile, Silvia Regina
dc.subject.por.fl_str_mv Physiotherapy
Pulmonology
Respiratory therapy
Fisioterapia
Pneumologia
Terapia respiratória
topic Physiotherapy
Pulmonology
Respiratory therapy
Fisioterapia
Pneumologia
Terapia respiratória
description IntroductionThe incentive spirometer helps pulmonary ventilation and the cardiorespiratory changes of its use are controversial. ObjectiveTo evaluate the effect of sets and repetitions on cardiorespiratory parameters using a spirometer alinear flow (SAF). The sample group consisted of 50 young people, healthy and sedentary. The evaluated parameters were: systolic blood pressure (SBP), diastolic (DBP), heart rate (HR), respiratory rate (RR), oxygen saturation (SaO2), minute volume (VE), tidal volume (VT), vital capacity (VC), maximal inspiratory pressure (Pimax), maximal expiratory pressure (Pemax), and peak expiratory flow (PEF). The moments of study were: initial evaluations (M1); 3 sets of 10 repetitions using SAF (M2); 3 sets of 15 repetitions using SAF (M3); and final evaluation (M4). Statistical analysis was made by t test, ANOVA and Tukey test (p < 0.05). ResultSBP and HR decreased in M2 after the 2nd set. In the 3rd set, SBP and RR decreased. Comparing the initial and final variables in M2, SBP and RR decreased, and Pemax increased. After 1st set in M3, SBP and SaO2 decreased. The 2nd set: SBP, HR, RR, and SaO2 decreased. After the 3rd set: SBP, HR, SaO2, and RR decreased. Comparing the initial and final variables in M3, SBP, HR, RR decreased, and Pimax and Pemax increased. Comparing M4 to M1, Pimax, Pemax, and VC increased, and RR decreased. ConclusionThere are changes in cardiorespiratory parameters after the use of a spirometer alinear flow, especially in the sets with more repetitions.
publishDate 2014
dc.date.none.fl_str_mv 2014-03-01
2015-02-02T12:39:22Z
2015-02-02T12:39:22Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/0103-5150.027.001.AO01
Fisioterapia em Movimento. Pontifícia Universidade Católica do Paraná, v. 27, n. 1, p. 11-19, 2014.
0103-5150
http://hdl.handle.net/11449/114236
10.1590/0103-5150.027.001.AO01
S0103-51502014000100011
S0103-51502014000100011.pdf
url http://dx.doi.org/10.1590/0103-5150.027.001.AO01
http://hdl.handle.net/11449/114236
identifier_str_mv Fisioterapia em Movimento. Pontifícia Universidade Católica do Paraná, v. 27, n. 1, p. 11-19, 2014.
0103-5150
10.1590/0103-5150.027.001.AO01
S0103-51502014000100011
S0103-51502014000100011.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Fisioterapia em Movimento
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 11-19
application/pdf
dc.publisher.none.fl_str_mv Pontifícia Universidade Católica do Paraná
publisher.none.fl_str_mv Pontifícia Universidade Católica do Paraná
dc.source.none.fl_str_mv SciELO
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129393939185664