The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1590/0103-5150.027.001.AO01 http://hdl.handle.net/11449/114236 |
Resumo: | IntroductionThe incentive spirometer helps pulmonary ventilation and the cardiorespiratory changes of its use are controversial. ObjectiveTo evaluate the effect of sets and repetitions on cardiorespiratory parameters using a spirometer alinear flow (SAF). The sample group consisted of 50 young people, healthy and sedentary. The evaluated parameters were: systolic blood pressure (SBP), diastolic (DBP), heart rate (HR), respiratory rate (RR), oxygen saturation (SaO2), minute volume (VE), tidal volume (VT), vital capacity (VC), maximal inspiratory pressure (Pimax), maximal expiratory pressure (Pemax), and peak expiratory flow (PEF). The moments of study were: initial evaluations (M1); 3 sets of 10 repetitions using SAF (M2); 3 sets of 15 repetitions using SAF (M3); and final evaluation (M4). Statistical analysis was made by t test, ANOVA and Tukey test (p < 0.05). ResultSBP and HR decreased in M2 after the 2nd set. In the 3rd set, SBP and RR decreased. Comparing the initial and final variables in M2, SBP and RR decreased, and Pemax increased. After 1st set in M3, SBP and SaO2 decreased. The 2nd set: SBP, HR, RR, and SaO2 decreased. After the 3rd set: SBP, HR, SaO2, and RR decreased. Comparing the initial and final variables in M3, SBP, HR, RR decreased, and Pimax and Pemax increased. Comparing M4 to M1, Pimax, Pemax, and VC increased, and RR decreased. ConclusionThere are changes in cardiorespiratory parameters after the use of a spirometer alinear flow, especially in the sets with more repetitions. |
id |
UNSP_27c8f33613385116516c8944297fa153 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/114236 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parametersEfeito das séries e repetições do inspirômetro a fluxo nos parâmetros cardiorrespiratóriosPhysiotherapyPulmonologyRespiratory therapyFisioterapiaPneumologiaTerapia respiratóriaIntroductionThe incentive spirometer helps pulmonary ventilation and the cardiorespiratory changes of its use are controversial. ObjectiveTo evaluate the effect of sets and repetitions on cardiorespiratory parameters using a spirometer alinear flow (SAF). The sample group consisted of 50 young people, healthy and sedentary. The evaluated parameters were: systolic blood pressure (SBP), diastolic (DBP), heart rate (HR), respiratory rate (RR), oxygen saturation (SaO2), minute volume (VE), tidal volume (VT), vital capacity (VC), maximal inspiratory pressure (Pimax), maximal expiratory pressure (Pemax), and peak expiratory flow (PEF). The moments of study were: initial evaluations (M1); 3 sets of 10 repetitions using SAF (M2); 3 sets of 15 repetitions using SAF (M3); and final evaluation (M4). Statistical analysis was made by t test, ANOVA and Tukey test (p < 0.05). ResultSBP and HR decreased in M2 after the 2nd set. In the 3rd set, SBP and RR decreased. Comparing the initial and final variables in M2, SBP and RR decreased, and Pemax increased. After 1st set in M3, SBP and SaO2 decreased. The 2nd set: SBP, HR, RR, and SaO2 decreased. After the 3rd set: SBP, HR, SaO2, and RR decreased. Comparing the initial and final variables in M3, SBP, HR, RR decreased, and Pimax and Pemax increased. Comparing M4 to M1, Pimax, Pemax, and VC increased, and RR decreased. ConclusionThere are changes in cardiorespiratory parameters after the use of a spirometer alinear flow, especially in the sets with more repetitions.Introdução Os incentivadores respiratórios auxiliam na ventilação pulmonar e as modificações cardiorrespiratórias mediante seu uso ainda são discutidas. Objetivo Avaliar efeito das séries e repetições com uso do inspirômetro alinear a fluxo (IAF) nos parâmetros cardiorrespiratórios. Materiais e métodos A amostra foi composta de 50 jovens, saudáveis e sedentários. Os parâmetros avaliados foram: pressão arterial (PA), frequência de pulso (FP), frequência respiratória (FR), saturação (SatO2), volume minuto (VM), volume corrente (VC), capacidade vital (CV), pressão inspiratória (Pimáx), pressão expiratória (Pemáx) e fluxometria. Os momentos foram: avaliações inicial (M1); uso do IAF em 3 séries de 10 repetições (M2); 3 séries de 15 repetições (M3); avaliação final (M4). A análise estatística se deu pelo teste “t” de Student, ANOVA e Teste de Tukey (p < 0,05). Resultados No M2, após a 2ª série houve diminuição da PAS e FP; na 3ª série: diminuição da PAS e FR. Comparando as variáveis iniciais e finais do M2, houve diminuição da PAS e FR, e aumento da Pemáx. No M3, 1ª série, houve diminuição da PAS e SatO2. Na 2ª série: diminuição da PAS, FP, FR e SatO2. Após a 3ª série: diminuição da PAS, FP, SatO2 e FR. Comparando as variáveis iniciais e finais do M3, houve diminuição da PAS, FP, FR; aumento da Pimáx e Pemáx. Comparando M4 com M1, houve aumento da Pimáx e Pemáx, diminuição da FR e aumento da CV. Conclusão Há alterações nos parâmetros cardiorrespiratórios após utilização do IAF, principalmente nas séries com maiores repetições.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Unesp Faculdade de Medicina de BotucatuUniversidade do Sagrado CoraçãoUniversidade Estadual PaulistaUnesp Faculdade de Medicina de BotucatuUniversidade Estadual PaulistaPontifícia Universidade Católica do ParanáUniversidade Estadual Paulista (Unesp)Universidade do Sagrado CoraçãoMartinelli, BrunoDamasceno E Souza, GiovanaRicci, Mariana Dela ColetaGimenes, CamilaDe Conti, Marta Helena SouzaBarrile, Silvia Regina2015-02-02T12:39:22Z2015-02-02T12:39:22Z2014-03-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article11-19application/pdfhttp://dx.doi.org/10.1590/0103-5150.027.001.AO01Fisioterapia em Movimento. Pontifícia Universidade Católica do Paraná, v. 27, n. 1, p. 11-19, 2014.0103-5150http://hdl.handle.net/11449/11423610.1590/0103-5150.027.001.AO01S0103-51502014000100011S0103-51502014000100011.pdfSciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengFisioterapia em Movimentoinfo:eu-repo/semantics/openAccess2024-01-04T06:26:21Zoai:repositorio.unesp.br:11449/114236Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T22:07:16.446395Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters Efeito das séries e repetições do inspirômetro a fluxo nos parâmetros cardiorrespiratórios |
title |
The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters |
spellingShingle |
The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters Martinelli, Bruno Physiotherapy Pulmonology Respiratory therapy Fisioterapia Pneumologia Terapia respiratória |
title_short |
The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters |
title_full |
The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters |
title_fullStr |
The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters |
title_full_unstemmed |
The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters |
title_sort |
The effect of sets and repetitions of the spirometer by flow in cardiorespiratory parameters |
author |
Martinelli, Bruno |
author_facet |
Martinelli, Bruno Damasceno E Souza, Giovana Ricci, Mariana Dela Coleta Gimenes, Camila De Conti, Marta Helena Souza Barrile, Silvia Regina |
author_role |
author |
author2 |
Damasceno E Souza, Giovana Ricci, Mariana Dela Coleta Gimenes, Camila De Conti, Marta Helena Souza Barrile, Silvia Regina |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) Universidade do Sagrado Coração |
dc.contributor.author.fl_str_mv |
Martinelli, Bruno Damasceno E Souza, Giovana Ricci, Mariana Dela Coleta Gimenes, Camila De Conti, Marta Helena Souza Barrile, Silvia Regina |
dc.subject.por.fl_str_mv |
Physiotherapy Pulmonology Respiratory therapy Fisioterapia Pneumologia Terapia respiratória |
topic |
Physiotherapy Pulmonology Respiratory therapy Fisioterapia Pneumologia Terapia respiratória |
description |
IntroductionThe incentive spirometer helps pulmonary ventilation and the cardiorespiratory changes of its use are controversial. ObjectiveTo evaluate the effect of sets and repetitions on cardiorespiratory parameters using a spirometer alinear flow (SAF). The sample group consisted of 50 young people, healthy and sedentary. The evaluated parameters were: systolic blood pressure (SBP), diastolic (DBP), heart rate (HR), respiratory rate (RR), oxygen saturation (SaO2), minute volume (VE), tidal volume (VT), vital capacity (VC), maximal inspiratory pressure (Pimax), maximal expiratory pressure (Pemax), and peak expiratory flow (PEF). The moments of study were: initial evaluations (M1); 3 sets of 10 repetitions using SAF (M2); 3 sets of 15 repetitions using SAF (M3); and final evaluation (M4). Statistical analysis was made by t test, ANOVA and Tukey test (p < 0.05). ResultSBP and HR decreased in M2 after the 2nd set. In the 3rd set, SBP and RR decreased. Comparing the initial and final variables in M2, SBP and RR decreased, and Pemax increased. After 1st set in M3, SBP and SaO2 decreased. The 2nd set: SBP, HR, RR, and SaO2 decreased. After the 3rd set: SBP, HR, SaO2, and RR decreased. Comparing the initial and final variables in M3, SBP, HR, RR decreased, and Pimax and Pemax increased. Comparing M4 to M1, Pimax, Pemax, and VC increased, and RR decreased. ConclusionThere are changes in cardiorespiratory parameters after the use of a spirometer alinear flow, especially in the sets with more repetitions. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-03-01 2015-02-02T12:39:22Z 2015-02-02T12:39:22Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/0103-5150.027.001.AO01 Fisioterapia em Movimento. Pontifícia Universidade Católica do Paraná, v. 27, n. 1, p. 11-19, 2014. 0103-5150 http://hdl.handle.net/11449/114236 10.1590/0103-5150.027.001.AO01 S0103-51502014000100011 S0103-51502014000100011.pdf |
url |
http://dx.doi.org/10.1590/0103-5150.027.001.AO01 http://hdl.handle.net/11449/114236 |
identifier_str_mv |
Fisioterapia em Movimento. Pontifícia Universidade Católica do Paraná, v. 27, n. 1, p. 11-19, 2014. 0103-5150 10.1590/0103-5150.027.001.AO01 S0103-51502014000100011 S0103-51502014000100011.pdf |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Fisioterapia em Movimento |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
11-19 application/pdf |
dc.publisher.none.fl_str_mv |
Pontifícia Universidade Católica do Paraná |
publisher.none.fl_str_mv |
Pontifícia Universidade Católica do Paraná |
dc.source.none.fl_str_mv |
SciELO reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129393939185664 |