A pH optode based on thymol blue: Application to determination of co2 using flow injection analy sis system
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.26850/1678-4618EQJ.V35.2.2010.P33-43 http://hdl.handle.net/11449/221676 |
Resumo: | An optode based on thymol blue (TB), an acid-based indicator, has been constructed and evaluated as a detector in FIA system for CO2determination. The dye was chemically immobilised on the surface of a bifurcated glass optical fibre bundle, using silanisation in organic media. In FIA system, hydrogen carbonate or carbonate samples are injected in a buffer carrier solution, and then are mixed with phosphoric acid solution to generate CO2, which diffuses through a PTFE membrane, in order to be collected in an acceptor carrier fluid, pumped towards to detection cell, in which the optode was adapted. The proposed system presents two linear response ranges, from 1.0 x 10-3to 1.0 x 10-2mol l-1, and from 2.0 x 10-2to 0.10 mol l-1. The sampling frequency was 11 sample h-1, with good repeatability (R.S.D < 4 %, n = 10). In flow conditions the optode lifetime was 170 h. The system was applied in the analysis of commercial mineral water and the results obtained in the hydrogen carbonate determination did not differ significantly from those obtained by potentiometry, at a confidence level of 95 %. |
id |
UNSP_2d4816359bc3dc2527312a8fcbdf8cb1 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/221676 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
A pH optode based on thymol blue: Application to determination of co2 using flow injection analy sis systemCO2FIApH-optodeSilanisationThymol blueAn optode based on thymol blue (TB), an acid-based indicator, has been constructed and evaluated as a detector in FIA system for CO2determination. The dye was chemically immobilised on the surface of a bifurcated glass optical fibre bundle, using silanisation in organic media. In FIA system, hydrogen carbonate or carbonate samples are injected in a buffer carrier solution, and then are mixed with phosphoric acid solution to generate CO2, which diffuses through a PTFE membrane, in order to be collected in an acceptor carrier fluid, pumped towards to detection cell, in which the optode was adapted. The proposed system presents two linear response ranges, from 1.0 x 10-3to 1.0 x 10-2mol l-1, and from 2.0 x 10-2to 0.10 mol l-1. The sampling frequency was 11 sample h-1, with good repeatability (R.S.D < 4 %, n = 10). In flow conditions the optode lifetime was 170 h. The system was applied in the analysis of commercial mineral water and the results obtained in the hydrogen carbonate determination did not differ significantly from those obtained by potentiometry, at a confidence level of 95 %.Instituto de Química; Unesp, São PauloInstituto de Química; Unicamp, São PauloSecretaria Municipal de Educação, São PauloInstituto de Química; Unesp, São PauloUniversidade Estadual Paulista (UNESP)Universidade Estadual de Campinas (UNICAMP)Secretaria Municipal de EducaçãoSotomayor, M. D.P.T. [UNESP]Raimundo, Jr.Rohwedder, J. J.R.Neto, G. Oliveira2022-04-28T19:30:00Z2022-04-28T19:30:00Z2010-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article33-43http://dx.doi.org/10.26850/1678-4618EQJ.V35.2.2010.P33-43Ecletica Quimica, v. 35, n. 2, p. 33-43, 2010.1678-46180100-4670http://hdl.handle.net/11449/22167610.26850/1678-4618EQJ.V35.2.2010.P33-432-s2.0-85100990286Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengEcletica Quimicainfo:eu-repo/semantics/openAccess2022-04-28T19:30:00Zoai:repositorio.unesp.br:11449/221676Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T18:58:15.489751Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
A pH optode based on thymol blue: Application to determination of co2 using flow injection analy sis system |
title |
A pH optode based on thymol blue: Application to determination of co2 using flow injection analy sis system |
spellingShingle |
A pH optode based on thymol blue: Application to determination of co2 using flow injection analy sis system Sotomayor, M. D.P.T. [UNESP] CO2 FIA pH-optode Silanisation Thymol blue |
title_short |
A pH optode based on thymol blue: Application to determination of co2 using flow injection analy sis system |
title_full |
A pH optode based on thymol blue: Application to determination of co2 using flow injection analy sis system |
title_fullStr |
A pH optode based on thymol blue: Application to determination of co2 using flow injection analy sis system |
title_full_unstemmed |
A pH optode based on thymol blue: Application to determination of co2 using flow injection analy sis system |
title_sort |
A pH optode based on thymol blue: Application to determination of co2 using flow injection analy sis system |
author |
Sotomayor, M. D.P.T. [UNESP] |
author_facet |
Sotomayor, M. D.P.T. [UNESP] Raimundo, Jr. Rohwedder, J. J.R. Neto, G. Oliveira |
author_role |
author |
author2 |
Raimundo, Jr. Rohwedder, J. J.R. Neto, G. Oliveira |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) Universidade Estadual de Campinas (UNICAMP) Secretaria Municipal de Educação |
dc.contributor.author.fl_str_mv |
Sotomayor, M. D.P.T. [UNESP] Raimundo, Jr. Rohwedder, J. J.R. Neto, G. Oliveira |
dc.subject.por.fl_str_mv |
CO2 FIA pH-optode Silanisation Thymol blue |
topic |
CO2 FIA pH-optode Silanisation Thymol blue |
description |
An optode based on thymol blue (TB), an acid-based indicator, has been constructed and evaluated as a detector in FIA system for CO2determination. The dye was chemically immobilised on the surface of a bifurcated glass optical fibre bundle, using silanisation in organic media. In FIA system, hydrogen carbonate or carbonate samples are injected in a buffer carrier solution, and then are mixed with phosphoric acid solution to generate CO2, which diffuses through a PTFE membrane, in order to be collected in an acceptor carrier fluid, pumped towards to detection cell, in which the optode was adapted. The proposed system presents two linear response ranges, from 1.0 x 10-3to 1.0 x 10-2mol l-1, and from 2.0 x 10-2to 0.10 mol l-1. The sampling frequency was 11 sample h-1, with good repeatability (R.S.D < 4 %, n = 10). In flow conditions the optode lifetime was 170 h. The system was applied in the analysis of commercial mineral water and the results obtained in the hydrogen carbonate determination did not differ significantly from those obtained by potentiometry, at a confidence level of 95 %. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-01-01 2022-04-28T19:30:00Z 2022-04-28T19:30:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.26850/1678-4618EQJ.V35.2.2010.P33-43 Ecletica Quimica, v. 35, n. 2, p. 33-43, 2010. 1678-4618 0100-4670 http://hdl.handle.net/11449/221676 10.26850/1678-4618EQJ.V35.2.2010.P33-43 2-s2.0-85100990286 |
url |
http://dx.doi.org/10.26850/1678-4618EQJ.V35.2.2010.P33-43 http://hdl.handle.net/11449/221676 |
identifier_str_mv |
Ecletica Quimica, v. 35, n. 2, p. 33-43, 2010. 1678-4618 0100-4670 10.26850/1678-4618EQJ.V35.2.2010.P33-43 2-s2.0-85100990286 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Ecletica Quimica |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
33-43 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129005075824640 |