Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line

Detalhes bibliográficos
Autor(a) principal: Di Nezio,María S.
Data de Publicação: 2005
Outros Autores: Palomeque,Miriam E., Band,Beatriz S. Fernández
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Química Nova (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422005000100025
Resumo: The spectrophotometric determination of Cd(II) using a flow injection system provided with a solid-phase reactor for cadmium preconcentration and on-line reagent preparation, is described. It is based on the formation of a dithizone-Cd complex in basic medium. The calibration curve is linear between 6 and 300 µg L-1 Cd(II), with a detection limit of 5.4 µg L-1, an RSD of 3.7% (10 replicates in duplicate) and a sample frequency of 11.4 h-1. The proposed method was satisfactorily applied to the determination of Cd(II) in surface, well and drinking waters.
id SBQ-3_22fddc5e4f654c619e7389c15f625f72
oai_identifier_str oai:scielo:S0100-40422005000100025
network_acronym_str SBQ-3
network_name_str Química Nova (Online)
repository_id_str
spelling Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-lineCd (II)preconcentrationFIAThe spectrophotometric determination of Cd(II) using a flow injection system provided with a solid-phase reactor for cadmium preconcentration and on-line reagent preparation, is described. It is based on the formation of a dithizone-Cd complex in basic medium. The calibration curve is linear between 6 and 300 µg L-1 Cd(II), with a detection limit of 5.4 µg L-1, an RSD of 3.7% (10 replicates in duplicate) and a sample frequency of 11.4 h-1. The proposed method was satisfactorily applied to the determination of Cd(II) in surface, well and drinking waters.Sociedade Brasileira de Química2005-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422005000100025Química Nova v.28 n.1 2005reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0100-40422005000100025info:eu-repo/semantics/openAccessDi Nezio,María S.Palomeque,Miriam E.Band,Beatriz S. Fernándezeng2005-02-23T00:00:00Zoai:scielo:S0100-40422005000100025Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2005-02-23T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line
title Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line
spellingShingle Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line
Di Nezio,María S.
Cd (II)
preconcentration
FIA
title_short Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line
title_full Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line
title_fullStr Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line
title_full_unstemmed Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line
title_sort Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line
author Di Nezio,María S.
author_facet Di Nezio,María S.
Palomeque,Miriam E.
Band,Beatriz S. Fernández
author_role author
author2 Palomeque,Miriam E.
Band,Beatriz S. Fernández
author2_role author
author
dc.contributor.author.fl_str_mv Di Nezio,María S.
Palomeque,Miriam E.
Band,Beatriz S. Fernández
dc.subject.por.fl_str_mv Cd (II)
preconcentration
FIA
topic Cd (II)
preconcentration
FIA
description The spectrophotometric determination of Cd(II) using a flow injection system provided with a solid-phase reactor for cadmium preconcentration and on-line reagent preparation, is described. It is based on the formation of a dithizone-Cd complex in basic medium. The calibration curve is linear between 6 and 300 µg L-1 Cd(II), with a detection limit of 5.4 µg L-1, an RSD of 3.7% (10 replicates in duplicate) and a sample frequency of 11.4 h-1. The proposed method was satisfactorily applied to the determination of Cd(II) in surface, well and drinking waters.
publishDate 2005
dc.date.none.fl_str_mv 2005-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422005000100025
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422005000100025
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0100-40422005000100025
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Química Nova v.28 n.1 2005
reponame:Química Nova (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Química Nova (Online)
collection Química Nova (Online)
repository.name.fl_str_mv Química Nova (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv quimicanova@sbq.org.br
_version_ 1750318104231018496