Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line
Autor(a) principal: | |
---|---|
Data de Publicação: | 2005 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Química Nova (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422005000100025 |
Resumo: | The spectrophotometric determination of Cd(II) using a flow injection system provided with a solid-phase reactor for cadmium preconcentration and on-line reagent preparation, is described. It is based on the formation of a dithizone-Cd complex in basic medium. The calibration curve is linear between 6 and 300 µg L-1 Cd(II), with a detection limit of 5.4 µg L-1, an RSD of 3.7% (10 replicates in duplicate) and a sample frequency of 11.4 h-1. The proposed method was satisfactorily applied to the determination of Cd(II) in surface, well and drinking waters. |
id |
SBQ-3_22fddc5e4f654c619e7389c15f625f72 |
---|---|
oai_identifier_str |
oai:scielo:S0100-40422005000100025 |
network_acronym_str |
SBQ-3 |
network_name_str |
Química Nova (Online) |
repository_id_str |
|
spelling |
Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-lineCd (II)preconcentrationFIAThe spectrophotometric determination of Cd(II) using a flow injection system provided with a solid-phase reactor for cadmium preconcentration and on-line reagent preparation, is described. It is based on the formation of a dithizone-Cd complex in basic medium. The calibration curve is linear between 6 and 300 µg L-1 Cd(II), with a detection limit of 5.4 µg L-1, an RSD of 3.7% (10 replicates in duplicate) and a sample frequency of 11.4 h-1. The proposed method was satisfactorily applied to the determination of Cd(II) in surface, well and drinking waters.Sociedade Brasileira de Química2005-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422005000100025Química Nova v.28 n.1 2005reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0100-40422005000100025info:eu-repo/semantics/openAccessDi Nezio,María S.Palomeque,Miriam E.Band,Beatriz S. Fernándezeng2005-02-23T00:00:00Zoai:scielo:S0100-40422005000100025Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2005-02-23T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line |
title |
Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line |
spellingShingle |
Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line Di Nezio,María S. Cd (II) preconcentration FIA |
title_short |
Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line |
title_full |
Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line |
title_fullStr |
Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line |
title_full_unstemmed |
Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line |
title_sort |
Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line |
author |
Di Nezio,María S. |
author_facet |
Di Nezio,María S. Palomeque,Miriam E. Band,Beatriz S. Fernández |
author_role |
author |
author2 |
Palomeque,Miriam E. Band,Beatriz S. Fernández |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Di Nezio,María S. Palomeque,Miriam E. Band,Beatriz S. Fernández |
dc.subject.por.fl_str_mv |
Cd (II) preconcentration FIA |
topic |
Cd (II) preconcentration FIA |
description |
The spectrophotometric determination of Cd(II) using a flow injection system provided with a solid-phase reactor for cadmium preconcentration and on-line reagent preparation, is described. It is based on the formation of a dithizone-Cd complex in basic medium. The calibration curve is linear between 6 and 300 µg L-1 Cd(II), with a detection limit of 5.4 µg L-1, an RSD of 3.7% (10 replicates in duplicate) and a sample frequency of 11.4 h-1. The proposed method was satisfactorily applied to the determination of Cd(II) in surface, well and drinking waters. |
publishDate |
2005 |
dc.date.none.fl_str_mv |
2005-02-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422005000100025 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422005000100025 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0100-40422005000100025 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Química Nova v.28 n.1 2005 reponame:Química Nova (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Química Nova (Online) |
collection |
Química Nova (Online) |
repository.name.fl_str_mv |
Química Nova (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
quimicanova@sbq.org.br |
_version_ |
1750318104231018496 |