Effectiveness of ATP bioluminescence assay for presumptive identification of microorganisms in hospital water sources

Detalhes bibliográficos
Autor(a) principal: Arroyo, Maira Gazzola [UNESP]
Data de Publicação: 2017
Outros Autores: Ferreira, Adriano Menis, Frota, Oleci Pereira, Rigotti, Marcelo Alessandro, Andrade, Denise de, Brizzotti, Natalia Seron, Macruz Peresi, Jacqueline Tanury, Castilho, Elza Maria, Gottardo de Almeida, Margarete Teresa
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1186/s12879-017-2562-y
http://hdl.handle.net/11449/163011
Resumo: Background: Laboratory analysis of organisms in water include arduous methods, such as the multiple tube and membrane filter. The ATP bioluminescence system, proposes a new way of measuring cellular material in water by measuring adenosine triphosphate (ATP) levels, which are expressed in relative light units (RLU). The ATP bioluminescence assay has been increasingly used to assess the microbiological safety of the hospital environment. However, there are few studies investigating the use of this methodology to evaluate the microbiological quality of water. The objective of the present study was to verify whether ATP, as measured by the 3 M (TM) Clean-Trace Water (TM) ATP test, can be used as an alternative tool for presumptive testing for the presence of microorganisms in hospital water. Methods: Water samples (N = 88) were collected from faucets (74) and water purifiers (14) in a university hospital. The sample were filtered by the membrane filter technique (100 mL for bacterial analysis and 100 mL for fungal analysis) and then submitted to ATP bioluminescence assay to the determine quantity of RLU in each sample. In order to compare RLU and the presence of microorganisms, a receiver operating characteristic (ROC) curve was used to calculate sensitivity and specificity (levels higher than 90% were considered significant). In addition, control tests were conducted to compare RLU to the quantities of bacterial and fungal organisms added to distilled water (ANOVA and Tukey's tests; p <= 0.05). This inoculum was compared to RLU emission, and the data were analyzed by calculating the Pearson's correlation coefficient, with a 95% confidence interval. Results: In the present study, 94.3% of the water samples presented bacterial growth. Of these, 15.6% showed heterotrophic bacteria above recommended levels and fungal contamination was detected in 55.6% of samples. Sensitivity and specificity of the samples were not significant (<90%), and the correlation between ATP and the presence of these microorganisms in the samples (hospital water) was not significant, whereas, in distilled water, the results revealed a significant difference (p < 0.0001). Conclusions: These results demonstrated that the ATP test cannot be used as an alternative tool for presumptive assessment of the presence of microorganisms in water.
id UNSP_330ed59e1739fc5c11d2eb87f19e5959
oai_identifier_str oai:repositorio.unesp.br:11449/163011
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Effectiveness of ATP bioluminescence assay for presumptive identification of microorganisms in hospital water sourcesAdenosine triphosphateBacteriaFungiHospitalWaterBackground: Laboratory analysis of organisms in water include arduous methods, such as the multiple tube and membrane filter. The ATP bioluminescence system, proposes a new way of measuring cellular material in water by measuring adenosine triphosphate (ATP) levels, which are expressed in relative light units (RLU). The ATP bioluminescence assay has been increasingly used to assess the microbiological safety of the hospital environment. However, there are few studies investigating the use of this methodology to evaluate the microbiological quality of water. The objective of the present study was to verify whether ATP, as measured by the 3 M (TM) Clean-Trace Water (TM) ATP test, can be used as an alternative tool for presumptive testing for the presence of microorganisms in hospital water. Methods: Water samples (N = 88) were collected from faucets (74) and water purifiers (14) in a university hospital. The sample were filtered by the membrane filter technique (100 mL for bacterial analysis and 100 mL for fungal analysis) and then submitted to ATP bioluminescence assay to the determine quantity of RLU in each sample. In order to compare RLU and the presence of microorganisms, a receiver operating characteristic (ROC) curve was used to calculate sensitivity and specificity (levels higher than 90% were considered significant). In addition, control tests were conducted to compare RLU to the quantities of bacterial and fungal organisms added to distilled water (ANOVA and Tukey's tests; p <= 0.05). This inoculum was compared to RLU emission, and the data were analyzed by calculating the Pearson's correlation coefficient, with a 95% confidence interval. Results: In the present study, 94.3% of the water samples presented bacterial growth. Of these, 15.6% showed heterotrophic bacteria above recommended levels and fungal contamination was detected in 55.6% of samples. Sensitivity and specificity of the samples were not significant (<90%), and the correlation between ATP and the presence of these microorganisms in the samples (hospital water) was not significant, whereas, in distilled water, the results revealed a significant difference (p < 0.0001). Conclusions: These results demonstrated that the ATP test cannot be used as an alternative tool for presumptive assessment of the presence of microorganisms in water.Sao Paulo State Univ, Grad Program Microbiol, St Cristovao Colombo 2265, BR-15054000 Sao Jose Do Rio Preto, SP, BrazilUniv Fed Mato Grosso do Sul, Master & Doctoral Grad Program Hlth & Dev West Ce, Av Costa & Silva,S-N 79070-900, Campo Grande, Mato Grosso Do, BrazilUniv Fed Mato Grosso do Sul, Master Grad Program Nursing, Av Costa & Silva,S-N 79070-900, Campo Grande, Mato Grosso Do, BrazilUniv Fed Mato Grosso do Sul, Undergrad Program Nursing, Av Ranulpho Marques Leal 3484, BR-79610100 Tres Lagoas, Mato Grosso Do, BrazilUniv Sao Paulo, Ribeirao Preto Coll Nursing, Dept Gen & Specialized Nursing, WHO Collaborating Ctr Nursing Res Dev, Av Bandeirantes 3900, BR-14040902 Ribeirao Preto, SP, BrazilFac Med Sao Jose do Rio Preto, Dept Infect & Parasit Dis, Av Brg Faria Lima 5416, BR-15090000 Sao Jose Do Rio Preto, SP, BrazilAdolfo Lutz Inst, Ctr Reg Lab Sao Jose do Rio Preto, St Rua Alberto Sufredini Bertoni 2325, BR-15060020 Sao Jose Do Rio Preto, SP, BrazilSao Paulo State Univ, Grad Program Microbiol, St Cristovao Colombo 2265, BR-15054000 Sao Jose Do Rio Preto, SP, BrazilBiomed Central LtdUniversidade Estadual Paulista (Unesp)Universidade Federal de Mato Grosso do Sul (UFMS)Universidade de São Paulo (USP)Fac Med Sao Jose do Rio PretoAdolfo Lutz InstArroyo, Maira Gazzola [UNESP]Ferreira, Adriano MenisFrota, Oleci PereiraRigotti, Marcelo AlessandroAndrade, Denise deBrizzotti, Natalia SeronMacruz Peresi, Jacqueline TanuryCastilho, Elza MariaGottardo de Almeida, Margarete Teresa2018-11-26T17:39:45Z2018-11-26T17:39:45Z2017-06-30info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article5application/pdfhttp://dx.doi.org/10.1186/s12879-017-2562-yBmc Infectious Diseases. London: Biomed Central Ltd, v. 17, 5 p., 2017.1471-2334http://hdl.handle.net/11449/16301110.1186/s12879-017-2562-yWOS:000405719000002WOS000405719000002.pdfWeb of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBmc Infectious Diseases1,576info:eu-repo/semantics/openAccess2023-12-17T06:18:20Zoai:repositorio.unesp.br:11449/163011Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462023-12-17T06:18:20Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Effectiveness of ATP bioluminescence assay for presumptive identification of microorganisms in hospital water sources
title Effectiveness of ATP bioluminescence assay for presumptive identification of microorganisms in hospital water sources
spellingShingle Effectiveness of ATP bioluminescence assay for presumptive identification of microorganisms in hospital water sources
Arroyo, Maira Gazzola [UNESP]
Adenosine triphosphate
Bacteria
Fungi
Hospital
Water
title_short Effectiveness of ATP bioluminescence assay for presumptive identification of microorganisms in hospital water sources
title_full Effectiveness of ATP bioluminescence assay for presumptive identification of microorganisms in hospital water sources
title_fullStr Effectiveness of ATP bioluminescence assay for presumptive identification of microorganisms in hospital water sources
title_full_unstemmed Effectiveness of ATP bioluminescence assay for presumptive identification of microorganisms in hospital water sources
title_sort Effectiveness of ATP bioluminescence assay for presumptive identification of microorganisms in hospital water sources
author Arroyo, Maira Gazzola [UNESP]
author_facet Arroyo, Maira Gazzola [UNESP]
Ferreira, Adriano Menis
Frota, Oleci Pereira
Rigotti, Marcelo Alessandro
Andrade, Denise de
Brizzotti, Natalia Seron
Macruz Peresi, Jacqueline Tanury
Castilho, Elza Maria
Gottardo de Almeida, Margarete Teresa
author_role author
author2 Ferreira, Adriano Menis
Frota, Oleci Pereira
Rigotti, Marcelo Alessandro
Andrade, Denise de
Brizzotti, Natalia Seron
Macruz Peresi, Jacqueline Tanury
Castilho, Elza Maria
Gottardo de Almeida, Margarete Teresa
author2_role author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Universidade Federal de Mato Grosso do Sul (UFMS)
Universidade de São Paulo (USP)
Fac Med Sao Jose do Rio Preto
Adolfo Lutz Inst
dc.contributor.author.fl_str_mv Arroyo, Maira Gazzola [UNESP]
Ferreira, Adriano Menis
Frota, Oleci Pereira
Rigotti, Marcelo Alessandro
Andrade, Denise de
Brizzotti, Natalia Seron
Macruz Peresi, Jacqueline Tanury
Castilho, Elza Maria
Gottardo de Almeida, Margarete Teresa
dc.subject.por.fl_str_mv Adenosine triphosphate
Bacteria
Fungi
Hospital
Water
topic Adenosine triphosphate
Bacteria
Fungi
Hospital
Water
description Background: Laboratory analysis of organisms in water include arduous methods, such as the multiple tube and membrane filter. The ATP bioluminescence system, proposes a new way of measuring cellular material in water by measuring adenosine triphosphate (ATP) levels, which are expressed in relative light units (RLU). The ATP bioluminescence assay has been increasingly used to assess the microbiological safety of the hospital environment. However, there are few studies investigating the use of this methodology to evaluate the microbiological quality of water. The objective of the present study was to verify whether ATP, as measured by the 3 M (TM) Clean-Trace Water (TM) ATP test, can be used as an alternative tool for presumptive testing for the presence of microorganisms in hospital water. Methods: Water samples (N = 88) were collected from faucets (74) and water purifiers (14) in a university hospital. The sample were filtered by the membrane filter technique (100 mL for bacterial analysis and 100 mL for fungal analysis) and then submitted to ATP bioluminescence assay to the determine quantity of RLU in each sample. In order to compare RLU and the presence of microorganisms, a receiver operating characteristic (ROC) curve was used to calculate sensitivity and specificity (levels higher than 90% were considered significant). In addition, control tests were conducted to compare RLU to the quantities of bacterial and fungal organisms added to distilled water (ANOVA and Tukey's tests; p <= 0.05). This inoculum was compared to RLU emission, and the data were analyzed by calculating the Pearson's correlation coefficient, with a 95% confidence interval. Results: In the present study, 94.3% of the water samples presented bacterial growth. Of these, 15.6% showed heterotrophic bacteria above recommended levels and fungal contamination was detected in 55.6% of samples. Sensitivity and specificity of the samples were not significant (<90%), and the correlation between ATP and the presence of these microorganisms in the samples (hospital water) was not significant, whereas, in distilled water, the results revealed a significant difference (p < 0.0001). Conclusions: These results demonstrated that the ATP test cannot be used as an alternative tool for presumptive assessment of the presence of microorganisms in water.
publishDate 2017
dc.date.none.fl_str_mv 2017-06-30
2018-11-26T17:39:45Z
2018-11-26T17:39:45Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1186/s12879-017-2562-y
Bmc Infectious Diseases. London: Biomed Central Ltd, v. 17, 5 p., 2017.
1471-2334
http://hdl.handle.net/11449/163011
10.1186/s12879-017-2562-y
WOS:000405719000002
WOS000405719000002.pdf
url http://dx.doi.org/10.1186/s12879-017-2562-y
http://hdl.handle.net/11449/163011
identifier_str_mv Bmc Infectious Diseases. London: Biomed Central Ltd, v. 17, 5 p., 2017.
1471-2334
10.1186/s12879-017-2562-y
WOS:000405719000002
WOS000405719000002.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Bmc Infectious Diseases
1,576
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 5
application/pdf
dc.publisher.none.fl_str_mv Biomed Central Ltd
publisher.none.fl_str_mv Biomed Central Ltd
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1803046986579968000