Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound
Autor(a) principal: | |
---|---|
Data de Publicação: | 2009 |
Outros Autores: | , , , |
Tipo de documento: | Artigo de conferência |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://www.ijo.cn/en_publish/2009/4/200904003.pdf http://hdl.handle.net/11449/12630 |
Resumo: | AIM: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound.METHODS: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery.RESULTS: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27.8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues.CONCLUSION: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provides useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation, |
id |
UNSP_3379679b13eefc7fb46d45c890359638 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/12630 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasoundpolyethylene implantB ultrasoundrabbitanophthalmic cavityAIM: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound.METHODS: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery.RESULTS: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27.8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues.CONCLUSION: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provides useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation,Univ Estadual Paulista, Fac Med Botucatu, Dept Ophthalmol, São Paulo, SP, BrazilUniv Estadual Paulista, Fac Med Botucatu, Dept Pathol, São Paulo, SP, BrazilUniv Estadual Paulista, Fac Med Botucatu, Dept Biostat, São Paulo, SP, BrazilUniv Estadual Paulista, Fac Med Botucatu, Dept Ophthalmol, São Paulo, SP, BrazilUniv Estadual Paulista, Fac Med Botucatu, Dept Pathol, São Paulo, SP, BrazilUniv Estadual Paulista, Fac Med Botucatu, Dept Biostat, São Paulo, SP, BrazilIjo PressUniversidade Estadual Paulista (Unesp)Barbarini Ferraz, Lucieni Cristina [UNESP]Schellini, Silvana Artioli [UNESP]Hoyama, Erika [UNESP]Wludarski, Sheila Lordelo [UNESP]Padovani, Carlos Roberto [UNESP]2014-05-20T13:36:41Z2014-05-20T13:36:41Z2009-12-18info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject291-293http://www.ijo.cn/en_publish/2009/4/200904003.pdfInternational Journal of Ophthalmology. Xi An: Ijo Press, v. 2, n. 4, p. 291-293, 2009.1672-5123http://hdl.handle.net/11449/12630WOS:00028293400000394202491008354928727897080522289Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengInternational Journal of Ophthalmology0,109info:eu-repo/semantics/openAccess2024-09-03T13:19:03Zoai:repositorio.unesp.br:11449/12630Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-03T13:19:03Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound |
title |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound |
spellingShingle |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound Barbarini Ferraz, Lucieni Cristina [UNESP] polyethylene implant B ultrasound rabbit anophthalmic cavity |
title_short |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound |
title_full |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound |
title_fullStr |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound |
title_full_unstemmed |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound |
title_sort |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound |
author |
Barbarini Ferraz, Lucieni Cristina [UNESP] |
author_facet |
Barbarini Ferraz, Lucieni Cristina [UNESP] Schellini, Silvana Artioli [UNESP] Hoyama, Erika [UNESP] Wludarski, Sheila Lordelo [UNESP] Padovani, Carlos Roberto [UNESP] |
author_role |
author |
author2 |
Schellini, Silvana Artioli [UNESP] Hoyama, Erika [UNESP] Wludarski, Sheila Lordelo [UNESP] Padovani, Carlos Roberto [UNESP] |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Barbarini Ferraz, Lucieni Cristina [UNESP] Schellini, Silvana Artioli [UNESP] Hoyama, Erika [UNESP] Wludarski, Sheila Lordelo [UNESP] Padovani, Carlos Roberto [UNESP] |
dc.subject.por.fl_str_mv |
polyethylene implant B ultrasound rabbit anophthalmic cavity |
topic |
polyethylene implant B ultrasound rabbit anophthalmic cavity |
description |
AIM: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound.METHODS: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery.RESULTS: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27.8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues.CONCLUSION: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provides useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation, |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009-12-18 2014-05-20T13:36:41Z 2014-05-20T13:36:41Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://www.ijo.cn/en_publish/2009/4/200904003.pdf International Journal of Ophthalmology. Xi An: Ijo Press, v. 2, n. 4, p. 291-293, 2009. 1672-5123 http://hdl.handle.net/11449/12630 WOS:000282934000003 9420249100835492 8727897080522289 |
url |
http://www.ijo.cn/en_publish/2009/4/200904003.pdf http://hdl.handle.net/11449/12630 |
identifier_str_mv |
International Journal of Ophthalmology. Xi An: Ijo Press, v. 2, n. 4, p. 291-293, 2009. 1672-5123 WOS:000282934000003 9420249100835492 8727897080522289 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
International Journal of Ophthalmology 0,109 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
291-293 |
dc.publisher.none.fl_str_mv |
Ijo Press |
publisher.none.fl_str_mv |
Ijo Press |
dc.source.none.fl_str_mv |
Web of Science reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1810021378102919168 |