Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound

Detalhes bibliográficos
Autor(a) principal: Ferraz, Lucieni Cristina Barbarini [UNESP]
Data de Publicação: 2009
Outros Autores: Schellini, Silvana Artioli [UNESP], Hoyama, Erika [UNESP], Wludarski, Sheila Lordelo [UNESP], Padovani, Carlos Roberto [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.3969/j.issn.1672-5123.2009.04.007
http://hdl.handle.net/11449/225466
Resumo: • Aim: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound. • Methods: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery. • Results: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27. 8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues. • Conclusion: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provided useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation.
id UNSP_ec992e584ef026589d019cf2d708bc62
oai_identifier_str oai:repositorio.unesp.br:11449/225466
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasoundAnophthalmic cavityB ultrasoundPolyethylene implantRabbit• Aim: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound. • Methods: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery. • Results: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27. 8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues. • Conclusion: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provided useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation.Department of Ophthalmology Faculdade de Medicina de Botucatu Universidade Estadual Paulista, São Paulo StateDepartment of Pathology Faculdade de Medicina de Botucatu Universidade Estadual Paulista, São Paulo StateDepartment of Biostatistics Faculdade de Medicina de Botucatu Universidade Estadual Paulista, São Paulo StateDepartment of Ophthalmology Faculdade de Medicina de Botucatu Universidade Estadual Paulista, São Paulo StateDepartment of Pathology Faculdade de Medicina de Botucatu Universidade Estadual Paulista, São Paulo StateDepartment of Biostatistics Faculdade de Medicina de Botucatu Universidade Estadual Paulista, São Paulo StateUniversidade Estadual Paulista (UNESP)Ferraz, Lucieni Cristina Barbarini [UNESP]Schellini, Silvana Artioli [UNESP]Hoyama, Erika [UNESP]Wludarski, Sheila Lordelo [UNESP]Padovani, Carlos Roberto [UNESP]2022-04-28T20:51:11Z2022-04-28T20:51:11Z2009-04-25info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article631-633http://dx.doi.org/10.3969/j.issn.1672-5123.2009.04.007International Journal of Ophthalmology, v. 9, n. 4, p. 631-633, 2009.1672-5123http://hdl.handle.net/11449/22546610.3969/j.issn.1672-5123.2009.04.0072-s2.0-65549083459Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengInternational Journal of Ophthalmologyinfo:eu-repo/semantics/openAccess2024-09-03T13:15:15Zoai:repositorio.unesp.br:11449/225466Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-03T13:15:15Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound
title Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound
spellingShingle Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound
Ferraz, Lucieni Cristina Barbarini [UNESP]
Anophthalmic cavity
B ultrasound
Polyethylene implant
Rabbit
title_short Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound
title_full Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound
title_fullStr Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound
title_full_unstemmed Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound
title_sort Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound
author Ferraz, Lucieni Cristina Barbarini [UNESP]
author_facet Ferraz, Lucieni Cristina Barbarini [UNESP]
Schellini, Silvana Artioli [UNESP]
Hoyama, Erika [UNESP]
Wludarski, Sheila Lordelo [UNESP]
Padovani, Carlos Roberto [UNESP]
author_role author
author2 Schellini, Silvana Artioli [UNESP]
Hoyama, Erika [UNESP]
Wludarski, Sheila Lordelo [UNESP]
Padovani, Carlos Roberto [UNESP]
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (UNESP)
dc.contributor.author.fl_str_mv Ferraz, Lucieni Cristina Barbarini [UNESP]
Schellini, Silvana Artioli [UNESP]
Hoyama, Erika [UNESP]
Wludarski, Sheila Lordelo [UNESP]
Padovani, Carlos Roberto [UNESP]
dc.subject.por.fl_str_mv Anophthalmic cavity
B ultrasound
Polyethylene implant
Rabbit
topic Anophthalmic cavity
B ultrasound
Polyethylene implant
Rabbit
description • Aim: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound. • Methods: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery. • Results: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27. 8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues. • Conclusion: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provided useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation.
publishDate 2009
dc.date.none.fl_str_mv 2009-04-25
2022-04-28T20:51:11Z
2022-04-28T20:51:11Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.3969/j.issn.1672-5123.2009.04.007
International Journal of Ophthalmology, v. 9, n. 4, p. 631-633, 2009.
1672-5123
http://hdl.handle.net/11449/225466
10.3969/j.issn.1672-5123.2009.04.007
2-s2.0-65549083459
url http://dx.doi.org/10.3969/j.issn.1672-5123.2009.04.007
http://hdl.handle.net/11449/225466
identifier_str_mv International Journal of Ophthalmology, v. 9, n. 4, p. 631-633, 2009.
1672-5123
10.3969/j.issn.1672-5123.2009.04.007
2-s2.0-65549083459
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv International Journal of Ophthalmology
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 631-633
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1810021385185001472