Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound
Autor(a) principal: | |
---|---|
Data de Publicação: | 2009 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.3969/j.issn.1672-5123.2009.04.007 http://hdl.handle.net/11449/225466 |
Resumo: | • Aim: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound. • Methods: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery. • Results: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27. 8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues. • Conclusion: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provided useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation. |
id |
UNSP_ec992e584ef026589d019cf2d708bc62 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/225466 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasoundAnophthalmic cavityB ultrasoundPolyethylene implantRabbit• Aim: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound. • Methods: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery. • Results: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27. 8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues. • Conclusion: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provided useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation.Department of Ophthalmology Faculdade de Medicina de Botucatu Universidade Estadual Paulista, São Paulo StateDepartment of Pathology Faculdade de Medicina de Botucatu Universidade Estadual Paulista, São Paulo StateDepartment of Biostatistics Faculdade de Medicina de Botucatu Universidade Estadual Paulista, São Paulo StateDepartment of Ophthalmology Faculdade de Medicina de Botucatu Universidade Estadual Paulista, São Paulo StateDepartment of Pathology Faculdade de Medicina de Botucatu Universidade Estadual Paulista, São Paulo StateDepartment of Biostatistics Faculdade de Medicina de Botucatu Universidade Estadual Paulista, São Paulo StateUniversidade Estadual Paulista (UNESP)Ferraz, Lucieni Cristina Barbarini [UNESP]Schellini, Silvana Artioli [UNESP]Hoyama, Erika [UNESP]Wludarski, Sheila Lordelo [UNESP]Padovani, Carlos Roberto [UNESP]2022-04-28T20:51:11Z2022-04-28T20:51:11Z2009-04-25info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article631-633http://dx.doi.org/10.3969/j.issn.1672-5123.2009.04.007International Journal of Ophthalmology, v. 9, n. 4, p. 631-633, 2009.1672-5123http://hdl.handle.net/11449/22546610.3969/j.issn.1672-5123.2009.04.0072-s2.0-65549083459Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengInternational Journal of Ophthalmologyinfo:eu-repo/semantics/openAccess2024-09-03T13:15:15Zoai:repositorio.unesp.br:11449/225466Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-03T13:15:15Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound |
title |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound |
spellingShingle |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound Ferraz, Lucieni Cristina Barbarini [UNESP] Anophthalmic cavity B ultrasound Polyethylene implant Rabbit |
title_short |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound |
title_full |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound |
title_fullStr |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound |
title_full_unstemmed |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound |
title_sort |
Gel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound |
author |
Ferraz, Lucieni Cristina Barbarini [UNESP] |
author_facet |
Ferraz, Lucieni Cristina Barbarini [UNESP] Schellini, Silvana Artioli [UNESP] Hoyama, Erika [UNESP] Wludarski, Sheila Lordelo [UNESP] Padovani, Carlos Roberto [UNESP] |
author_role |
author |
author2 |
Schellini, Silvana Artioli [UNESP] Hoyama, Erika [UNESP] Wludarski, Sheila Lordelo [UNESP] Padovani, Carlos Roberto [UNESP] |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) |
dc.contributor.author.fl_str_mv |
Ferraz, Lucieni Cristina Barbarini [UNESP] Schellini, Silvana Artioli [UNESP] Hoyama, Erika [UNESP] Wludarski, Sheila Lordelo [UNESP] Padovani, Carlos Roberto [UNESP] |
dc.subject.por.fl_str_mv |
Anophthalmic cavity B ultrasound Polyethylene implant Rabbit |
topic |
Anophthalmic cavity B ultrasound Polyethylene implant Rabbit |
description |
• Aim: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound. • Methods: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery. • Results: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27. 8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues. • Conclusion: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provided useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation. |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009-04-25 2022-04-28T20:51:11Z 2022-04-28T20:51:11Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.3969/j.issn.1672-5123.2009.04.007 International Journal of Ophthalmology, v. 9, n. 4, p. 631-633, 2009. 1672-5123 http://hdl.handle.net/11449/225466 10.3969/j.issn.1672-5123.2009.04.007 2-s2.0-65549083459 |
url |
http://dx.doi.org/10.3969/j.issn.1672-5123.2009.04.007 http://hdl.handle.net/11449/225466 |
identifier_str_mv |
International Journal of Ophthalmology, v. 9, n. 4, p. 631-633, 2009. 1672-5123 10.3969/j.issn.1672-5123.2009.04.007 2-s2.0-65549083459 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
International Journal of Ophthalmology |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
631-633 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1810021385185001472 |